I've seen the PID associated to the STC not be cleared up on a hard shutdown, that then prevented the task restarting.
Jerry Whitteridge Delivery Manager - Safeway 602 527 4871 Mobile [email protected] IBM Services IBM Mainframe Discussion List <[email protected]> wrote on 02/19/2018 03:05:30 PM: > From: Tony Thigpen <[email protected]> > To: [email protected] > Date: 02/19/2018 03:05 PM > Subject: LPSERVE not starting > Sent by: IBM Mainframe Discussion List <[email protected]> > > We were testing some new shut-down procedures on our sandbox lPAR and > somehow we have messed up LPSERVE. > > When it starts, it gets the following error: > > EZY1980E MVPMAIN terminating due to previous error(s). > > The last time it started correctly, the output had the following : > EZB0831I IBM MVS LPD Version CS V2R10 on 02/16/18 at 08:13:47 > EZB0832I > EZB0705I 02/16/18 08:13:47 > EZB0834I Ready > EZB0622E Could not get notice (TCP/IP service is being shut down (8558) > > I have IPLed multiple times and can't seem to get rid of the problem. > > Any thoughts? > > -- > Tony Thigpen > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to [email protected] with the message: INFO IBM-MAIN > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN