Sorry for not responding earlier, I had Friday off.

SMF record 42 is for DFSMS statistics, so I avoided the SMF42* undefined 
symbols and the invalid R4 by setting &RT_DFSMS to 0.

SMF record 82 is for ICSF, so I got rid of the SMF82ITE undefined symbol by 
&RT_ICSF to 0.

And you still have to set &ST_DFSMS07 to N for a clean assembly.

Ant.

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf 
Of Sankaranarayanan, Vignesh
Sent: Friday, 18 May 2018 9:40 PM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: [EXTERNAL] Re: DAF (CBT 094) - Unknown Datatype x01BB

.. I have a compiled DAF from earlier which works for DATASET EQ stuff, but it 
doesn't recognize the RACF keywords, though I probably would have let the RACF 
flag default to a yes when I asm it years ago.

– Vignesh
Mainframe Infrastructure

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf 
Of Sankaranarayanan, Vignesh
Sent: 18 May 2018 13:08
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: [EXTERNAL] Re: DAF (CBT 094) - Unknown Datatype x01BB

Hi Anthony,

Looks like I'm getting DAF assemble errors to now..

** ASMA044E Undefined symbol - SMF42S7
** ASMA044E Undefined symbol - SMF42FFS
** ASMA044E Undefined symbol - SMF42FTY
** ASMA044E Undefined symbol - SMF42FTM
** ASMA044E Undefined symbol - SMF42FSN
** ASMA044E Undefined symbol - SMF42FDN
** ASMA044E Undefined symbol - SMF42FIR
** ASMA044E Undefined symbol - SMF42FIW
** ASMA044E Undefined symbol - SMF42FNL
** ASMA044E Undefined symbol - SMF42FFN
** ASMA044E Undefined symbol - SMF42FFN

I don't want to disable the RACF flag as I intend to use the features enabled 
by it.
Is it still required to set ST_DFSMS07 as a 'NO'?

– Vignesh
Mainframe Infrastructure

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf 
Of Anthony Thompson
Sent: 17 May 2018 04:52
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: [EXTERNAL] Re: DAF (CBT 094) - Unknown Datatype x01BB

I downloaded the latest DAF from the CBT site and assembled it, without any 
serious problems. I turned off most options (&RT_<whatever> SETC C'000', also 
&ST_DFSMS07 SETC 'NO ' to get it to assemble, as noted in the DAF comments).

I did not get an "Unknown Datatype x'011b'" if I provided DAF with only SMF 
type 14/15, using a single control card of 'DATASET EQ <my TSO userid>'. That 
message seems to be associated with processing SMF type 80 records (RACF). I 
also avoided the same error if I excluded RACF SMF records in DAF input but 
included all others. Curiously, I still get that error message if I specify 
&RT_RACF  SETC 'NO ' and re-assemble DAF, and include type 80 SMF records in 
DAF input.

I also get a crapload of ' Unknown Data    AUDAT=    )' messages (not when 
using only SMF type14/15 as DAF input). I wish I had the time to diagnose these 
DAF errors further.

Note I am on z/OS 2.3.

As for knowing which jobs expand which PROCLIB members, I'm wondering if you 
can expose the IEFC001I message that usually appears in a job's JESYSMG dataset 
to SYSLOG/OPERLOG via a MPFLST member (that's the message that says this 
procedure / include group was expanded from this system / private library). 
Various automation products can also mess with route codes. Then you'd just 
need to scan a saved SYSLOG/OPERLOG to find out what you want to know.

Ant.

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf 
Of Ravi Gaur
Sent: Wednesday, 16 May 2018 4:18 PM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: DAF (CBT 094) - Unknown Datatype x01BB

Has anyone seen on z/OS2.2 I see DAF is reporting "Unknown Datatype x01BB" and 
while downloading and assemble/linkedit latest CBT 094 gives me 0255 for 
various undefined symbol though I have checked the maclib .

anyone the point is has anyone recent ran DAF against SMF data for 14/15 for 
DATASET EQ xxxx and got Unknown datatype message?


Also I know it's a separate topic but I have a requirement to know which procs 
are being expanded by which job from the proclib so trying to get that and 
PDSMAN do report a little for READ/BROWSE function against the members if it's 
enable to cut the smf record however doesn't report correct job name...so if 
anybody also has idea if similar been in past a necessity for them to know and 
how they achieved it will be great to know as well.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
lists...@listserv.ua.edu with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
lists...@listserv.ua.edu with the message: INFO IBM-MAIN

MARKSANDSPENCER.COM
________________________________
 Unless otherwise stated above:
Marks and Spencer plc
Registered Office:
Waterside House
35 North Wharf Road
London
W2 1NW

Registered No. 214436 in England and Wales.

Telephone (020) 7935 4422
Facsimile (020) 7487 2670

www.marksandspencer.com

Please note that electronic mail may be monitored.

This e-mail is confidential. If you received it by mistake, please let us know 
and then delete it from your system; you should not copy, disclose, or 
distribute its contents to anyone nor act in reliance on this e-mail, as this 
is prohibited and may be unlawful.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
lists...@listserv.ua.edu with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
lists...@listserv.ua.edu with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to