Hi Lizette, That was the intent of the OP. I then hijacked his thread as I had a similar query with DAF.
– Vignesh Mainframe Infrastructure -----Original Message----- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of Lizette Koehler Sent: Monday 21-May-2018 07:54 To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: [EXTERNAL] Re: DAF (CBT 094) - Unknown Datatype x01BB I think the intent is identifying what used a member in a PDS. For example, knowing which jobs expand which PROCLIB members Lizette > -----Original Message----- > From: IBM Mainframe Discussion List <IBM-MAIN@LISTSERV.UA.EDU> On > Behalf Of Anthony Thompson > Sent: Sunday, May 20, 2018 7:13 PM > To: IBM-MAIN@LISTSERV.UA.EDU > Subject: Re: [EXTERNAL] Re: DAF (CBT 094) - Unknown Datatype x01BB > > If all you are looking for is who has opened a dataset, SMF type 14 is > all you should need. > > Ant. > > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] > On Behalf Of Sankaranarayanan, Vignesh > Sent: Monday, 21 May 2018 11:37 AM > To: IBM-MAIN@LISTSERV.UA.EDU > Subject: Re: [EXTERNAL] Re: DAF (CBT 094) - Unknown Datatype x01BB > > Thanks Ant, wouldnt setting SMF42 off mean I can't use DATASET EQ > <something> stuff? > > – Vignesh > Mainframe Infrastructure > > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] > On Behalf Of Anthony Thompson > Sent: Monday 21-May-2018 06:57 > To: IBM-MAIN@LISTSERV.UA.EDU > Subject: Re: [EXTERNAL] Re: DAF (CBT 094) - Unknown Datatype x01BB > > Sorry for not responding earlier, I had Friday off. > > SMF record 42 is for DFSMS statistics, so I avoided the SMF42* > undefined symbols and the invalid R4 by setting &RT_DFSMS to 0. > > SMF record 82 is for ICSF, so I got rid of the SMF82ITE undefined > symbol by &RT_ICSF to 0. > > And you still have to set &ST_DFSMS07 to N for a clean assembly. > > Ant. > > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] > On Behalf Of Sankaranarayanan, Vignesh > Sent: Friday, 18 May 2018 9:40 PM > To: IBM-MAIN@LISTSERV.UA.EDU > Subject: Re: [EXTERNAL] Re: DAF (CBT 094) - Unknown Datatype x01BB > > .. I have a compiled DAF from earlier which works for DATASET EQ > stuff, but it doesn't recognize the RACF keywords, though I probably > would have let the RACF flag default to a yes when I asm it years ago. > > – Vignesh > Mainframe Infrastructure > > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] > On Behalf Of Sankaranarayanan, Vignesh > Sent: 18 May 2018 13:08 > To: IBM-MAIN@LISTSERV.UA.EDU > Subject: Re: [EXTERNAL] Re: DAF (CBT 094) - Unknown Datatype x01BB > > Hi Anthony, > > Looks like I'm getting DAF assemble errors to now.. > > ** ASMA044E Undefined symbol - SMF42S7 > ** ASMA044E Undefined symbol - SMF42FFS > ** ASMA044E Undefined symbol - SMF42FTY > ** ASMA044E Undefined symbol - SMF42FTM > ** ASMA044E Undefined symbol - SMF42FSN > ** ASMA044E Undefined symbol - SMF42FDN > ** ASMA044E Undefined symbol - SMF42FIR > ** ASMA044E Undefined symbol - SMF42FIW > ** ASMA044E Undefined symbol - SMF42FNL > ** ASMA044E Undefined symbol - SMF42FFN > ** ASMA044E Undefined symbol - SMF42FFN > > I don't want to disable the RACF flag as I intend to use the features > enabled by it. > Is it still required to set ST_DFSMS07 as a 'NO'? > > – Vignesh > Mainframe Infrastructure > > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] > On Behalf Of Anthony Thompson > Sent: 17 May 2018 04:52 > To: IBM-MAIN@LISTSERV.UA.EDU > Subject: [EXTERNAL] Re: DAF (CBT 094) - Unknown Datatype x01BB > > I downloaded the latest DAF from the CBT site and assembled it, > without any serious problems. I turned off most options > (&RT_<whatever> SETC C'000', also > &ST_DFSMS07 SETC 'NO ' to get it to assemble, as noted in the DAF comments). > > I did not get an "Unknown Datatype x'011b'" if I provided DAF with > only SMF type 14/15, using a single control card of 'DATASET EQ <my > TSO userid>'. That message seems to be associated with processing SMF > type 80 records (RACF). I also avoided the same error if I excluded > RACF SMF records in DAF input but included all others. Curiously, I > still get that error message if I specify &RT_RACF SETC 'NO ' and > re-assemble DAF, and include type 80 SMF records in DAF input. > > I also get a crapload of ' Unknown Data AUDAT= )' messages (not when > using only SMF type14/15 as DAF input). I wish I had the time to > diagnose these DAF errors further. > > Note I am on z/OS 2.3. > > As for knowing which jobs expand which PROCLIB members, I'm wondering > if you can expose the IEFC001I message that usually appears in a job's > JESYSMG dataset to SYSLOG/OPERLOG via a MPFLST member (that's the > message that says this procedure / include group was expanded from > this system / private library). Various automation products can also > mess with route codes. Then you'd just need to scan a saved > SYSLOG/OPERLOG to find out what you want to know. > > Ant. > > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] > On Behalf Of Ravi Gaur > Sent: Wednesday, 16 May 2018 4:18 PM > To: IBM-MAIN@LISTSERV.UA.EDU > Subject: DAF (CBT 094) - Unknown Datatype x01BB > > Has anyone seen on z/OS2.2 I see DAF is reporting "Unknown Datatype x01BB" > and while downloading and assemble/linkedit latest CBT 094 gives me > 0255 for various undefined symbol though I have checked the maclib . > > anyone the point is has anyone recent ran DAF against SMF data for > 14/15 for DATASET EQ xxxx and got Unknown datatype message? > > > Also I know it's a separate topic but I have a requirement to know > which procs are being expanded by which job from the proclib so trying > to get that and PDSMAN do report a little for READ/BROWSE function > against the members if it's enable to cut the smf record however > doesn't report correct job name...so if anybody also has idea if > similar been in past a necessity for them to know and how they achieved it > will be great to know as well. > > > MARKSANDSPENCER.COM > ________________________________ > Unless otherwise stated above: > Marks and Spencer plc > Registered Office: > Waterside House > 35 North Wharf Road > London > W2 1NW > > Registered No. 214436 in England and Wales. > > Telephone (020) 7935 4422 > Facsimile (020) 7487 2670 > > www.marksandspencer.com ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN