We don't have ZZSA, so I can't comment on the original question. But we 
happened to do an IPL today on a sandbox system, so I watched it on the 3270 
integrated console. 

I was seeing messages from the system until it was shut down. Continued 
watching for a while, then got distracted. When I went back to it, normal 
system message traffic was displaying. No <Enter> was necessary to initiate the 
flow. These were post-NIP 'sysplex enabled' messages, same as were showing on 
SNA SMCS through another member of the same sysplex. 

I wasn't focused during NIP, but my experience with integrated 3270 is the same 
as with Operating System Messages. NIP messages will display on the HMC only if 
(1) no NIP consoles are defined in IODF, or (2) no IODF-defined consoles are 
'physically available' from NIP's perspective. In contrast to IODF, we define 
SADMP with CONSOLE=SYSC, i.e. HMC. 

No experience with standalone DSS or DSF for comparison.

.
.
J.O.Skip Robinson
Southern California Edison Company
Electric Dragon Team Paddler 
SHARE MVS Program Co-Manager
323-715-0595 Mobile
626-543-6132 Office ⇐=== NEW
[email protected]

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of Tom Brennan
Sent: Friday, October 05, 2018 8:53 AM
To: [email protected]
Subject: (External):Re: [EXTERNAL] Re: ZZSA question

I just tested ZZSA under Hercules and like I thought, when you connect via 
Hercules TN3270 to simulate a console, after IPL no ZZSA messages appear until 
you press Enter.  That means ZZSA sits waiting for an interrupt from a 3270 
device, and uses that device for the rest of the communication.  To me, that 
means it works just like SADUMP, DFDSS, and ICKDSF and there is no console 
configuration.

On 10/5/2018 8:20 AM, Dyck, Lionel B. (RavenTek) wrote:
> I've tested ZZSA under Hercules - Thanks to Sam Golob's fine work - but I 
> didn't see how to define a console as an HMC integretated console (hmcs) ?
> 
> ----------------------------------------------------------------------
> ----
> Lionel B. Dyck (Contractor)  <sdg><
> Mainframe Systems Programmer – RavenTek Solution Partners
> 
> 
> 
> 
> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[email protected]] 
> On Behalf Of Tom Brennan
> Sent: Friday, October 05, 2018 10:14 AM
> To: [email protected]
> Subject: [EXTERNAL] Re: ZZSA question
> 
> Oh... you mean HMC console.  New answer:  I did not try that, but prior to 
> going to that site I had never user ZZSA before so I tested it under 
> Hercules, and that simulates the HMC console I believe, so I'd bet the answer 
> is yes.
> 
> On 10/5/2018 8:07 AM, Tom Brennan wrote:
>> I used (well mostly watched) ZZSA work via ICC with no problems.  
>> That was a couple of years ago on a new z13s with OSA 5S cards.
>>
>> On 10/5/2018 4:58 AM, Dyck, Lionel B. (RavenTek) wrote:
>>> Does anyone know if the ZZSA tool (stand alone utilities) on the 
>>> CBTTape can use the HMC Integrated Console?
>>>
>>> --------------------------------------------------------------------
>>> -
>>> -----
>>>
>>> Lionel B. Dyck (Contractor)  <sdg><
>>> Mainframe Systems Programmer - RavenTek Solution Partners

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to