Hello Babara/David, hints enough in your 2 posts to locate the manual:-
PARM('NEW(text value)') Exceptions should only be issued for user key common storage usage attempts that are detected after this parameter is set. The 'text value' is free-form and is not used by health check processing. It should contain text to help the user uniquely identify this particular parameter set. The following are examples of PARM specifications for ZOSMIGV2R3_NEXT_VSM_USERKEYCOMM: PARM('NEW(yyyy/mm/dd hh:mm)') PARM('ALL') before UPDATE command:- IGVH113I Use of user key common storage was not detected since 03/28/2019 13:47:36 F HZSPROC,UPDATE,CHECK(IBMVSM,ZOSMIGV2R3_NEXT_VSM_USERKEYCOMM),parm=('new(reset 04/16/2019)') after UPDATE command:-IGVH113I Use of user key common storage was not detected since 04/16/2019 02:14:44 timely posts. Thanks Bruce Hewson ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN