On Wed, 25 Mar 2020 15:43:47 +0000, Seymour J Metz wrote:

>Why? I suspect that only Mike knows.
>
MFC?  I suspect it was out of his control before that happened.

>Worse, the same manual has an example where the name is longer than 8 
>characters.
>
Oh, don't you make me search for it.  ITYM:
    
https://www.ibm.com/support/knowledgecenter/SSLTBW_2.4.0/com.ibm.zos.v2r4.ikja300/mvsvarr.htm
     
That is, IEASYMxx contains the definitions:

SYMDEF(&LONG_SYMBOL_NAME='SY1T_ON_PLEX_A44T')
SYMDEF(&EXTSYM_='<==THIS VALUE CAN BE UP TO 44 CHARS LONG===>')

Then, the MVSVAR function can be used to retrieve the values of these symbols 
as shown:

z1 = MVSVAR('SYMDEF','LONG_SYMBOL_NAME')
z2 = MVSVAR('SYMDEF','EXTSYM_')

For z1:
<- Returns z1: SY1T_ON_PLEX_A44T

For z2:
<- Returns z2: <==THIS VALUE CAN BE UP TO 44 CHARS LONG===>

-- gil

----------------------------------------------------------------------