https://issues.apache.org/jira/browse/FLINK-6462?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=16010211#comment-16010211
]
ASF GitHub Bot commented on FLINK-6462:
---------------------------------------
Github user fhueske commented on a diff in the pull request:
https://github.com/apache/flink/pull/3851#discussion_r116443377
--- Diff:
flink-libraries/flink-table/src/test/scala/org/apache/flink/table/api/scala/stream/table/GroupWindowTest.scala
---
@@ -30,6 +30,23 @@ import org.junit.{Ignore, Test}
class GroupWindowTest extends TableTestBase {
+ /**
+ * OVER clause is necessary for [[OverAgg0]] window function.
+ */
+ @Test(expected = classOf[TableException])
+ def testOverAggregation(): Unit = {
+ val util = streamTestUtil()
+ val table = util.addTable[(Long, Int, String)]('long, 'int, 'string,
'proctime.proctime)
+
+ val overAgg = new OverAgg0
+ val windowedTable = table
+ .window(Tumble over 2.rows on 'proctime as 'w)
+ .groupBy('w, 'string)
+ .select(overAgg('long, 'int))
+
+ util.verifyTable(windowedTable, "n/a")
--- End diff --
When the check is done in validation phase, we do not have to call
`verifyTable()` (same for all other Table API tests).
> Add requiresOver interface for AggregateFunction
> -------------------------------------------------
>
> Key: FLINK-6462
> URL: https://issues.apache.org/jira/browse/FLINK-6462
> Project: Flink
> Issue Type: Improvement
> Components: Table API & SQL
> Reporter: sunjincheng
> Assignee: sunjincheng
> Fix For: 1.3.0
>
>
> The window function in the standard database only supports the "over" window,
> such as `LAG`,` LEAD`, `FIRST_VALUE`,` LAST_VALUE`. These window functions do
> not apply to `Slide`,` Tumble`, `Session` window. So when the user-defined
> AGG need to be clearly defined. In calcite `SqlAggFunction` will using
> `requiresOver` to distinguish.
> In this JIRA. will deal with this feature.
--
This message was sent by Atlassian JIRA