Am 15.06.2016 um 19:59 schrieb Alan Altmark:
On Wednesday, 06/15/2016 at 03:11 GMT, Terry Madge
<[email protected]> wrote:
================================================================================
-> 0000000000002590 SSCH B2339000 000000000000FF20 CC 0
SCH 0000 DEV 0100
CPA 00008410 PARM 00000000 KEY 0 FPI 80 LPM 80
VDEV 0100 CCW 66400001 00000080 STS 0E
-> 0000000000002590 SSCH B2339000 000000000000FF20 CC 3
Start subchannel failed
:
HCPGIR450W CP entered; disabled wait PSW 00020000 80000000 00000000
00004502
Hmmmm.... What the heck is CCW op code X'66'? Something took the device
offline or detached it from the guest. A real I/O error would have been
reflected to the OPERATOR's console.
I do not know where the CCW 0x66 comes from. The bootloader only uses
0x06, 0x41, 0x42, 0x43 and 0x63 for FBA.
Also I was unable to reproduce this issue on my system but one of our
tester reported he was able to do so.
I will try to investigate what happens.
Regards
Stefan
----------------------------------------------------------------------