> Gesendet: Dienstag, 30. März 2021 um 00:07 Uhr
> Von: "Chris Murphy" <li...@colorremedies.com>
> An: "B A" <chris....@web.de>
> Cc: "Btrfs BTRFS" <linux-btrfs@vger.kernel.org>
> Betreff: Re: Help needed with filesystem errors: parent transid verify failed
>
> On Sun, Mar 28, 2021 at 9:41 AM B A <chris....@web.de> wrote:
> >
> > * Samsung 840 series SSD (SMART data looks fine)
> 
> EVO or PRO? And what does its /proc/mounts line look like?

Model is MZ-7TD500, which seems to be an EVO. Firmware is DXT08B0Q.

>From /etc/fstab:

UUID=1a149bda-057d-4775-ba66-1bf259fce9a5 /        btrfs   
subvol=root-f23,x-systemd.device-timeout=0,compress=lzo,ssd,noatime 0 0
UUID=1b1f5c60-57f3-435c-b73e-2de727a302e2 /boot    ext4    nosuid,noexec,nodev  
      1 2
UUID=1a149bda-057d-4775-ba66-1bf259fce9a5 /home    btrfs   
subvol=home,x-systemd.device-timeout=0,compress=lzo,ssd,nosuid,nodev,noatime 0 0
UUID=1a149bda-057d-4775-ba66-1bf259fce9a5 /var     btrfs   
subvol=var-f23,x-systemd.device-timeout=0,compress=lzo,ssd,nosuid,noexec,nodev,noatime
 0 0

> Total_LBAs_Written?

Raw value: 92857573119
(full output in attached file)


Kind regards,
Chris
smartctl 7.2 2021-01-17 r5171 [x86_64-linux-5.8.15-301.fc33.x86_64] (local 
build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Samsung based SSDs
Device Model:     Samsung SSD 840 Series
Serial Number:    [removed]
LU WWN Device Id: [removed]
Firmware Version: DXT08B0Q
User Capacity:    500,107,862,016 bytes [500 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
TRIM Command:     Available, deterministic, zeroed
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ACS-2, ATA8-ACS T13/1699-D revision 4c
SATA Version is:  SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is:    Tue Mar 30 04:37:16 2021 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                (53956) seconds.
Offline data collection
capabilities:                    (0x53) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        No Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (  70) minutes.
SCT capabilities:              (0x003d) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  5 Reallocated_Sector_Ct   0x0033   100   100   010    Pre-fail  Always       
-       0
  9 Power_On_Hours          0x0032   097   097   000    Old_age   Always       
-       12588
 12 Power_Cycle_Count       0x0032   091   091   000    Old_age   Always       
-       8958
177 Wear_Leveling_Count     0x0013   089   089   000    Pre-fail  Always       
-       131
179 Used_Rsvd_Blk_Cnt_Tot   0x0013   100   100   010    Pre-fail  Always       
-       0
181 Program_Fail_Cnt_Total  0x0032   100   100   010    Old_age   Always       
-       0
182 Erase_Fail_Count_Total  0x0032   100   100   010    Old_age   Always       
-       0
183 Runtime_Bad_Block       0x0013   100   100   010    Pre-fail  Always       
-       0
187 Uncorrectable_Error_Cnt 0x0032   100   100   000    Old_age   Always       
-       0
190 Airflow_Temperature_Cel 0x0032   073   051   000    Old_age   Always       
-       27
195 ECC_Error_Rate          0x001a   200   200   000    Old_age   Always       
-       0
199 CRC_Error_Count         0x003e   099   099   000    Old_age   Always       
-       4
235 POR_Recovery_Count      0x0012   099   099   000    Old_age   Always       
-       1958
241 Total_LBAs_Written      0x0032   099   099   000    Old_age   Always       
-       92857573119

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Extended offline    Completed without error       00%      1935         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
  255        0    65535  Read_scanning was never started
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

Reply via email to