Since you are graphing temperature - I assume in degrees C, for one variable - you may also want:
Ylegend[xxx]: Temperature LegendI[xxx]: temp: ShortLegend[xxx]: degC Options[xxx]: noo gauge Legend1[xxx]: Device temperature Legend3[xxx]: Peak device temperature routers.cgi*Options[xxx]: fixunit nopercent nomax These will set the Y-axis legend, and the units, prevent the display of the superfluous second variable, and prevent display of the percentages, maximum line, and any prefixes to the ShortLegend. The gauge option is probably missing from your second graph example. Steve ________________________________ From: Mersberger, Robert [mailto:[EMAIL PROTECTED] Sent: Wednesday, 27 August 2008 10:12 To: Anson Rinesmith; Steve Shipway; [email protected] Subject: RE: [mrtg] Want to monitor System temperature of 2811 router - Need OID Looks like I am getting data now but now I need help getting the information on the chart correct. Any suggestions My cfg. is as below.
_______________________________________________ mrtg mailing list [email protected] https://lists.oetiker.ch/cgi-bin/listinfo/mrtg