I always use:
Target[xxx]: <OID1>&<OID2>:<SNMP String>@<IP Address> *1.8 + 32

And thank you for doing all the leg work here. I didn't realize this OID was 
available for 2811s. I wonder if it will work on my 1841s as well...

Thanks,
Garry

From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Mersberger, 
Robert
Sent: Wednesday, August 27, 2008 12:09 PM
To: Steve Shipway; [email protected]
Subject: Re: [mrtg] Want to monitor System temperature of 2811 router - Need OID

Thanks much for the info as it really helped clear things up for me. Now I have 
one last question and that is what would I have to do to convert this graph or 
getting the information as degrees C would it be possible to convert that to 
degrees F for the graph?

Thanks again for you assistance.



________________________________
From: Steve Shipway [mailto:[EMAIL PROTECTED]
Sent: Tuesday, August 26, 2008 8:41 PM
To: Mersberger, Robert; '[email protected]'
Subject: RE: [mrtg] Want to monitor System temperature of 2811 router - Need OID
Since you are graphing temperature - I assume in degrees C, for one variable - 
you may also want:

Ylegend[xxx]: Temperature
LegendI[xxx]: temp:
ShortLegend[xxx]: degC
Options[xxx]: noo gauge
Legend1[xxx]: Device temperature
Legend3[xxx]: Peak device temperature
routers.cgi*Options[xxx]: fixunit nopercent nomax

These will set the Y-axis legend, and the units, prevent the display of the 
superfluous second variable, and prevent display of the percentages, maximum 
line, and any prefixes to the ShortLegend.  The gauge option is probably 
missing from your second graph example.

Steve

________________________________
From: Mersberger, Robert [mailto:[EMAIL PROTECTED]
Sent: Wednesday, 27 August 2008 10:12
To: Anson Rinesmith; Steve Shipway; [email protected]
Subject: RE: [mrtg] Want to monitor System temperature of 2811 router - Need OID

Looks like I am getting data now but now I need help getting the information on 
the chart correct.  Any suggestions
My cfg. is as below.





Please consider the environment before printing this e-mail.

CONFIDENTIAL NOTICE:
This e-mail message and any attachment(s) (collectively, this 'Email') are 
intended
only for the confidential use of the recipient(s) named above. If the reader of 
this
message is not the intended recipient named above or an agent responsible for
delivering it to the intended recipient named above, you have received this 
Email in error.
Please notify the sender immediately and permanently delete this Email and any 
copies thereof.

________________________________
NOTICE: This e-mail and any files transmitted with it are the property of 
ARCADIS U.S., Inc. and its affiliates. All rights, including without limitation 
copyright, are reserved. The proprietary information contained in this e-mail 
message, and any files transmitted with it, is intended for the use of the 
recipient(s) named above. If the reader of this e-mail is not the intended 
recipient, you are hereby notified that you have received this e-mail in error 
and that any review, distribution or copying of this e-mail or any files 
transmitted with it is strictly prohibited. If you have received this e-mail in 
error, please notify the sender immediately and delete the original message and 
any files transmitted. The unauthorized use of this e-mail or any files 
transmitted with it is prohibited and disclaimed by ARCADIS U.S., Inc. and its 
affiliates.
_______________________________________________
mrtg mailing list
[email protected]
https://lists.oetiker.ch/cgi-bin/listinfo/mrtg

Reply via email to