Hi Thomas,
 
nice fix :-)
 
I'm no S-100 bus signalling expert but I would have logically expected the 
Data lines to be settled and valid at the point in time the WR* signal goes 
low, this would seem to not be the case in this instance. I don't see this 
as a fault in the IDE card design but rather that the device driving the 
card (CPU card) is not performing as we would expect.
 
Part of the fun of mixing old and new technology perhaps ???
 
regards
 
David Fry
On Monday, June 9, 2014 8:27:54 PM UTC+1, Thomas Owen wrote:

> UPDATE:
>
> As  mentioned, I set up a delay by using the 2 unused gates on the 74LS02 
> to delay the clock signal to the flip flop.  *Drive selection now works 
> perfectly*.
>
> I will see if I can get a screen shot from the analyzer showing the 
> relationship of DO0 to the clock, but for now, here is what I did:
>
> U15 pin 1 -> U15 pin 5/6  | U15 pin 4 -> U15 pin 8/9 | U15 pin 10 -> U16 
> pin 3
>
> Thomas
>
>
> On Sunday, June 8, 2014 7:58:45 PM UTC-4, Thomas Owen wrote: 
>>
>> All,
>> I had posted this to the thread dealing with ordering this card, but 
>> decided to post a new topic dealing with the problem I have had with final 
>> checkout of the board. 
>>
>> During assembly the board passed all the 'in progress' checks.  The final 
>> steps were to output to different ports:
>>
>>
>> I have output the following and everything passes:
>>
>> QO33,80 ; Configures ports A, B and C as output ports
>> QO32,2B ; Selects right hand pair of digits
>> QO30,01; display 01on right digit pair and work through each bit - all ok
>>
>> QO32,2c; Selects middle pair of digits
>> QO30,01; Should display 01 on middle digit pair, work through each bit - 
>> all ok
>>
>> QO32,2d; Selects left hand pair of digits
>> QO31,01; Should display 01 on left digit pair, work through each bit - 
>> all ok
>>
>> All displays are correct.
>>
>> Now the final step is the Drive Select and that is where I am having 
>> trouble:
>>
>> Board always comes up with 'Drive A' selected
>>
>> Now,  QO34,0; no change
>>
>> Reset, start again:
>>
>> QO34,1; no change
>>
>> I can never select drive B.   
>>
>> Several generous members (thank you David Fry) have made suggestions, and 
>> here is where I now stand:
>>
>> My preliminary check this afternoon shows me that there is a timing issue 
>> at U15, the 74ls02.  Using my logic analyzer and monitoring the inputs and 
>> the output (which clocks the drive select flip flop) I see a big timing 
>> difference between SEL_SECOND and WR.
>>
>> What this means is that the output of the gate never goes high allowing 
>> the bit change to effect drive change/selection.
>>
>> I am going to get some screen shots from the analyzer tomorrow, and if 
>> anyone has any suggestions I would greatly appreciate it.
>>
>> Thanks,
>> Thomas
>>
>>        

-- 
You received this message because you are subscribed to the Google Groups 
"N8VEM-S100" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
For more options, visit https://groups.google.com/d/optout.

Reply via email to