Update 2 - I've found a 130,5V transil at work, so I've been able to 
substitute a nixie tube with a nice dummy load. Results are: 208V supply, 
139V dropped on transil, 49V dropped on 3x33k resistors in parallel, rest 
dropped on my limiter. Current is 4,55mA. Everything seems to work just as 
expected! 

-- 