Am 06.12.2016 um 09:42 schrieb Martin Patzak (GMX):
> 
> yes, I could repeat it today. This time I stopped first the other task 
> reading the temperature nodes.
> I cannot read a straight value of 85 degC, instead I get this 
> transaction error. The values I can read are just above or just below 85 
> degC.
> 
> I can provide debug from owserver if it would help you figuring out 
> whats going on. Please advise.
> 
Yes please.

> You mentionened the manuals recieved an update regarding the new 
> latesttemp node. I am sorry to ask this, but where do I find this. I did 
> update owfs-doc to 3.1p4 but cannot find latesttemp anywhere. Is it 
> somewhere else I should be looking?
> 
In the DS18B20 et al. manpages. Please give a link to that package you
installed. Maybe it's broken.


Kind regards

        Jan

------------------------------------------------------------------------------