I tested it and I can confirm that writing to /uncached/simultaneous/voltage increases the CRC16_error by one.
Mick, do you have voltage devices on your network? (I hope it is not a stupid question) I don't have such devices, so I cannot test this further... Greetings, Marty On 13.08.20 01:04, Mick Sulley wrote: > > I have been doing some more testing and have a couple of issues. My > code sets simultaneous/temperature, waits a couple of seconds then > reads latesttemp from each sensor. > > 1. Reading latesttemp generally takes 0.07 seconds BUT every 120 > seconds every sensor takes 0.75 seconds for a single loop, then > back to 0.07 seconds. (/settings/timeout/presence is set to 120) > 2. My understanding is that simultaneous/voltage works in the same > way, however when I set it my CRC_errors increases by 8. Why is this? > > Cheers > > Mick > >
_______________________________________________ Owfs-developers mailing list Owfs-developers@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/owfs-developers