I set my 0603's up with a padsize of 32 mil , outline of 28 mil pad centre to overlay centre and place them using component grid of 8 mil and snap grid of 4 mil. This allows placment so that the overlays can sit on top of its neighbours overlay exactly and there is 24 thou clearance between pads. Then normal 8/8 routing can be used and a track can go between adjacent 0603 underneath the overlay with no DRC errors.
Dennis Saputelli <[EMAIL PROTECTED]> on 21/02/2005 05:42:38 AM Please respond to Protel EDA Discussion List <[email protected]> To: Protel EDA Discussion List <[email protected]>r cc: (bcc: Clive Broome/sdc) Subject: Re: [PEDA] how close 0603 how close do y'all pack 0603's side by side ? Dennis Saputelli _______________________________________________________________________ Integrated Controls, Inc. Tel: 415-647-0480 EXT 107 2851 21st Street Fax: 415-647-3003 San Francisco, CA 94110 www.integratedcontrolsinc.com ____________________________________________________________ You are subscribed to the PEDA discussion forum To Post messages: mailto:[email protected] Unsubscribe and Other Options: http://techservinc.com/mailman/listinfo/peda_techservinc.com Browse or Search Old Archives (2001-2004): http://www.mail-archive.com/[email protected] Browse or Search Current Archives (2004-Current): http://www.mail-archive.com/[email protected] ____________________________________________________________ You are subscribed to the PEDA discussion forum To Post messages: mailto:[email protected] Unsubscribe and Other Options: http://techservinc.com/mailman/listinfo/peda_techservinc.com Browse or Search Old Archives (2001-2004): http://www.mail-archive.com/[email protected] Browse or Search Current Archives (2004-Current): http://www.mail-archive.com/[email protected]