Josh Berkus <[email protected]> writes: >> What about the HBA here? > > Hmmm. That's tempting; an "synchronous" HBA instead of a GUC? But that > doesn't solve the problem of "standby #6 is failing, I want to kick it > off synch rep". > > I'd be opposed to having a GUC *and* an HBA. making DBAs set things > independantly in two places just frustrates our users.
I was just thinking that you could prepend a reject line at the right place in the file. Regards, -- Dimitri Fontaine http://2ndQuadrant.fr PostgreSQL : Expertise, Formation et Support -- Sent via pgsql-hackers mailing list ([email protected]) To make changes to your subscription: http://www.postgresql.org/mailpref/pgsql-hackers