Hi Chuck and gang Here are some values for 2 meters (GE MASTRII)air variable cap 2-14 pF with fixed 15pF in paralell to ground on input side next 3 to 4 turns #14 wire wound about 3/8" to a air veriable 2-24 pF in paralell with 10 pF fixed to ground on the out put side. for UHF the fixed caps are deleted. I would use 2-30pF air veriables for VHF and leave out the fixed units. The veriables are adjusted and the coil can be compressed or expanded to make adjustments. 73 AC0Y
--- In [email protected], "Chuck Kelsey" <[EMAIL PROTECTED]> wrote: > Seems with all the talk on here about the benefits of using an impedance > matcher at the repeater's transmitter output, someone could come up with > some construction information for the group. > > Chuck > WB2EDV Yahoo! Groups Links To visit your group on the web, go to: http://groups.yahoo.com/group/Repeater-Builder/ To unsubscribe from this group, send an email to: [EMAIL PROTECTED] Your use of Yahoo! Groups is subject to: http://docs.yahoo.com/info/terms/