Greetings from NC at 2:45AM

After arising at about 2:00 AM for a nature call, I noticed on my 
scanner, an un-modulated signal.  I turned on the lights in the 
house to check the channel on the scanner.  Damnit, it's my 2 meter 
repeater!  I don't know how long its been keyed up cause I've been 
sleeping (not anymore tonight).  I attempted to disable the 
controler (zetron model 37) and got all the right response codes but 
the repeater is still chugging right along.  It has a 3 minute 
timeout timer set on the controller and the morse ID is set for 10 
minutes.  Its been about 45 minutes since I've been up and no ID and 
no timeout.  I'm not sure if the repeater (msr2000) has the stock 
timeout timer card still installed or not, I can't remember.  There 
is nothing I can do at this hour as the repeater is a business 
rooftop installation with no access until 10:00AM.  My thoughts are 
that my controller went south cause I can key the repeater and hear 
the courtesy beep when I unkey but I still get no morse ID and also 
I also totally reset the controller to the factory defaults and the 
repeater still stays keyed.  I'm surprised my PA hasn't burned up 
yet...intermittant duty set at about 55 watts.  Any thoughts from 
you folks at what other things I might look for in the AM?


Thanks a bunch

Bob, GMRS WPVV845, Amateur KG4WAD, LMRS WPXC892





 