Hi Deepak,
If this is a metalloprotein, include higher concentration of the metal in
the crystallization drop. It may act as a glue in the interfaces and give
you a good crystal.
Jackie Vitali
Cleveland State University
On Tue, May 18, 2021 at 6:20 AM Deepak Deepak
wrote:
> Dear all,
>
> I
There is an anisotropy server from ucla that I think you can use over the
internet, Just google it and try it to see if it helps with your data. I
think the data is better afterwards,
Jackie Vitali
Cleveland State University
On Sat, Jan 13, 2018 at 5:53 AM, Zhang Foggy
The easiest is modeller via chimera.
You can use I-TASSER server but it decides for itself what to do... You
have some control too. You can use the sec structure from itasser and then
go to modeller in chimera
You can use modeller in the interfaces it provides in the web (mod web ...)
or
coot, lsq command
i have not checked chimera but it may have too. (I think so)
For coot. I used it recently for a small molecule.
And pymol
Finally the superpose server may do it.
On Jul 8, 2015, at 3:41 PM, Bernhard Rupp (Hofkristallrat a.D.)
hofkristall...@gmail.com wrote:
Hi Fellows,
Dear colleagues,
I know this is not related to ccp4 but I am in need of an answer and many
of you work with cells etc.
My building had a major malfunction of electricity and the power backup did
not kick in. My -80C freezer was without power for over 24 hours until I
found out. Because it is
Phil Jeffrey has a small program to calculate avg. I/sig for Table 1
including for resolution ranges.
Jackie Vitali
On Wed, Feb 12, 2014 at 11:20 AM, Ronald E Stenkamp
stenk...@u.washington.edu wrote:
How did people get I/sigmI when using HKL2000? Ron
On Wed, 12 Feb 2014, Phil Evans
I do not have experience with this but it is worth trying.
On Fri, Dec 27, 2013 at 2:29 PM, Mahesh Lingaraju mxl1...@psu.edu wrote:
Dear all,
I was wondering if it sounds logical to use the crystals from a possible
structural homolog as seeds to induce nucleation ? (in terms of overall
Mintu Chandra,
align is gerson cohen's program. Unless you talk about another align.
I googled align for linux Gerson Cohen and here is what I found -- the
linux version
http://software.compbio.washington.edu/ramp/ramp/src/other_source/align.save.f
Test it and see if it works.
If not, there
Dear all,
I used the guidechem chemical network to obtain a compound that is not sold
in US. Many people responded and I was persuaded to try to buy it from
SHANGHAI JIEKE BIOTECHNOLOGY LIMITED COMPANY
Adress:NO.1008 Qigangroad,FengXianZone,ShangHai,China
Tel :+86-031-97265503
Fax
Dear all,
Arginine sepharose 4B is an affinity column. If you have used it please
let me know where you purchased it.
GE Lifesciences used to sell it but discontinued it.
I found it in China in the site http://www.pharmaceutical-sales.net
and I corresponded with their sales representative
Dear Colleagues,
Does anyone have access to this article? It is not in my library and they
cannot find it via interlibrary loan. I know the limitations and that it
is best not to ask papers via the newsgroup but I have even tried to ask
the author for a reprint and my email was returned to me.
Yes, it has happened to me more than once. It is not a good pump. Acta
Prime Plus has a better one. They still have parts. Call GE technical
support and they will tell you what to do.
The part costs some money (it is not cheap - probably $500). I think the
Akta Prime will keep on running as
try file search monomer library. Hit search without typing anything. It
will give you what it has.
Jackie Vitali
2011/10/12 Dr. STEPHEN SIN-YIN, CHUI chui...@hkucc.hku.hk
Dear All,
For all monomers (3 letter) used in COOT, where can i find the full names
of the
whole library? Many thanks
Dear colleagues,
I need some advice for a new computer.
(1) I have the option of an HP Z210 8 GB with a low end Quadro Nvidia 400
512 MB.
--How does Coot run with this card?
--I am happy with any Linux. However, the system needs updates for security
purposes (the University requires it). Do
Dear colleagues,
Has anyone seen glycerol on a three-fold axis?
THis is possible as the glycerol can be disordered but I want to know if
there is an actual case.
Any information would be greatly appreciated.
Jackie Vitali
Dear colleagues,
I needed cryo -sleeves 22 mm ID so that I could put standard epitubes in
cryo canes and protect them. The epitubes do not hold as good as the cryo
vials in the cryo canes.
All commercially available cryo sleeves are 16 mm ID and are made for cryo
vials. Some of us put cultures
I think one of the options of PISA is to calculate accessibilities -- I
recall when I was learning how to use pisa that I saw this option.
Also DSSP outputs accessibilities per residue
Areaimol in ccp4 does too.
I have seen many programs in the internet, google accessibilities,
accessible
Hi,
I have seen this happening when I had NCS and did not include it in
refinement. Rwork drops and Rfree increases. In this case the difference
became small when I included the NCS.
Also if your Rmerge is high and you include all reflections in refinement,
Rfree is high. In my experience, by
Dear colleagues,
Thank you for your suggestions. I was able to do the refinement of the
sulfates and tartaric acid in phenix by changing the occupancies to 0.33 and
0.5,
It appears to me (from the log file and from graphics afterwards) that the
program automatically turns off the interaction
Dear colleagues,
I have a tartaric acid on a two fold axis with its two halves related
by the two fold. How do I refine this in Phenix?
Also I have a SO4 on a 3 fold with S and one O on tthe 3 fold. The
other 3 oxygens are related by the 3-fold. How do I refine this in
phenix? I can put S
Dear all,
Does anyone know the effect of a fire alarm placed in the same room where
one grows crystals?
(1) On trays placed inside styrofoam boxes
(2) On trays placed inside an incubator which has not been tested as
vibration free.
Thank you.
Jackie Vitali
Dear all,
I have a high mosaic spread for a structure (1.2 deg). It refines well to
low R values. The temp factors become very high in this structure. I
assume the reason is the high mosaicity. Are the coordinates also affected
by high mosaicity?
I would appreciate any input.
Thanks.
Dear colleagues,
I have an Akta Prime. I have always had problem with the reproducibility of
the peak heights of the various peaks. Recently the pump is breaking. Does
anyone have an idea what can cause the pump to break? It is more than once.
Jackie Vitali
Dear colleagues,
Does anyone have a copy of the old program DSCAN or MSCAN by S.T. Rao?
It calculates torsion angles in small molecules.
Alternatively, does anyone have a program to calculate torsion angles
and their ESD's for small molecules?
Thanks.
Jackie Vitali
Dear colleagues,
I am trying to find a cuvette for Dynapro 99-CP. Wyatt does not seem to
have these cuvettes. If anyone knows where I can get one please let me
know.
Thanks.
Jackie Vitali
Look at the paper (search in pubmed) by B. M. Schick and F. Jurnak on
cryoprotection of TuTs. He changes the reservoir in 24 steps using a 24
well cryschem plate. There are some references there that are important
too.
Jackie Vitali
On Mon, Jun 23, 2008 at 8:14 PM, Ji lee [EMAIL PROTECTED]
Dear colleagues:
I added a few lamdas of NaOH and dissolved it. Thank you all for the
responses.
Jackie Vitali