Hello
I was hoping to follow up on this email and if Florian manage to get to the
bottom of this.
I have a case where I believe my RGW bucket is using too much space. For me,
the ceph df command shows over 16TB usage, whereas the bucket stats shows the
total of about 6TB. So, It seems that the
Thanks for trying to help, Igor.
> From: "Igor Fedotov"
> To: "Andrei Mikhailovsky"
> Cc: "ceph-users"
> Sent: Thursday, 4 July, 2019 12:52:16
> Subject: Re: [ceph-users] troubleshooting space usage
> Yep, this looks fine..
> hmm... sorry,
, 2019 13:49:02
> Subject: Re: [ceph-users] troubleshooting space usage
> Looks fine - comparing bluestore_allocated vs. bluestore_stored shows a little
> difference. So that's not the allocation overhead.
> What's about comparing object counts reported by ceph and radosgw t
ely different from allocation overhead. Looks
> like
> some orphaned objects in the pool. Could you please compare and share the
> amounts of objects in the pool reported by "ceph (or rados) df detail" and
> radosgw tools?
> Thanks,
> Igor
> On 7/3/2019 12:56 PM, And
might also want to collect and share performance counter dumps (ceph
> daemon
> osd.N perf dump) and "
> " reports from a couple of your OSDs.
> Thanks,
> Igor
> On 7/2/2019 11:43 AM, Andrei Mikhailovsky wrote:
>> Bump!
>>> From: "Andrei Mik
Bump!
> From: "Andrei Mikhailovsky"
> To: "ceph-users"
> Sent: Friday, 28 June, 2019 14:54:53
> Subject: [ceph-users] troubleshooting space usage
> Hi
> Could someone please explain / show how to troubleshoot the space usage in
> Ceph
> and how to
Hi
Could someone please explain / show how to troubleshoot the space usage in Ceph
and how to reclaim the unused space?
I have a small cluster with 40 osds, replica of 2, mainly used as a backend for
cloud stack as well as the S3 gateway. The used space doesn't make any sense to
me, especial
It would be interesting to learn the improvements types and the BIOS changes
that helped you.
Thanks
> From: "Martin Verges"
> To: "Robert Sander"
> Cc: "ceph-users"
> Sent: Wednesday, 29 May, 2019 10:19:09
> Subject: Re: [ceph-users] performance in a small cluster
> Hello Robert,
>> We h
Hi Christian,
- Original Message -
> From: "Christian Balzer"
> To: "ceph-users"
> Cc: "Andrei Mikhailovsky"
> Sent: Tuesday, 16 October, 2018 08:51:36
> Subject: Re: [ceph-users] Luminous with osd flapping, slow requests when deep
> sc
Hello,
I am currently running Luminous 12.2.8 on Ubuntu with 4.15.0-36-generic kernel
from the official ubuntu repo. The cluster has 4 mon + osd servers. Each osd
server has the total of 9 spinning osds and 1 ssd for the hdd and ssd pools.
The hdds are backed by the S3710 ssds for journaling w
r us, there's no guarantee that they will work for you.
> Read it very carefully and recheck every step before executing it.
>
> Regards,
> Eugen
>
> [1]
> http://lists.ceph.com/pipermail/ceph-users-ceph.com/2018-February/024913.html
> [2]
> http://heiterbiswolkig.blo
Hello everyone,
I am wondering if it is possible to move the ssd journal for the bluestore osd?
I would like to move it from one ssd drive to another.
Thanks
___
ceph-users mailing list
ceph-users@lists.ceph.com
http://lists.ceph.com/listinfo.cgi/ce
Hello everyone,
I am in the process of adding an additional osd server to my small ceph cluster
as well as migrating from filestore to bluestore. Here is my setup at the
moment:
Ceph - 12.2.5 , running on Ubuntu 16.04 with latest updates
3 x osd servers with 10x3TB SAS drives, 2 x Intel S371
Dear cephers,
Could someone tell me how to check the rbd volumes modification times in ceph
pool? I am currently in the process of trimming our ceph pool and would like to
start with volumes which were not modified for a long time. How do I get that
information?
Cheers
Andrei
Thanks Richard,
That sounds impressive, especially the around 30% hit ratio. That would be
ideal for me, but we were only getting single digit results during my trials. I
think around 5% was the figure if I remember correctly.
However, most of our vms were created a bit chaotically (not using p
index . All other pools look
okay so far.
I am wondering what could have got horribly wrong with the above pool?
Cheers
Andrei
- Original Message -
> From: "Brad Hubbard"
> To: "Andrei Mikhailovsky"
> Cc: "ceph-users"
> Sent: Thursday, 28
Hi Richard,
It is an interesting test for me too as I am planning to migrate to Bluestore
storage and was considering repurposing the ssd disks that we currently use for
journals.
I was wondering if you are using the Filestore or the bluestone for the osds?
Also, when you perform your testing,
; : "",
"snapid" : -2,
"max" : 0
},
"truncate_size" : 0,
"version" : "120985'632942",
"expected_object_size" : 0,
"omap_digest" : "0x&q
"num_write_kb": 0,
"num_scrub_errors": 0,
"num_shallow_scrub_errors": 0,
"num_deep_scrub_errors": 0,
"num_objects_recovered": 207,
r you
> can query any other pg that has osd.21 as its primary?
>
> On Mon, Jun 25, 2018 at 8:04 PM, Andrei Mikhailovsky
> wrote:
>> Hi Brad,
>>
>> here is the output:
>>
>> --
>>
>> root@arh-ibstorage1-ib:/home/andrei# ceph
2.168.168.201:0/3046734987 wait
complete.
2018-06-25 10:59:12.112764 7fe244b28700 1 -- 192.168.168.201:0/3046734987 >>
192.168.168.201:0/3046734987 conn(0x7fe240167220 :-1 s=STATE_NONE pgs=0 cs=0
l=0).mark_down
2018-06-25 10:59:12.112770 7fe244b28700 2 -- 192.168.168.201:0/3046734987 >>
t; Subject: Re: [ceph-users] fixing unrepairable inconsistent PG
> That seems like an authentication issue?
>
> Try running it like so...
>
> $ ceph --debug_monc 20 --debug_auth 20 pg 18.2 query
>
> On Thu, Jun 21, 2018 at 12:18 AM, Andrei Mikhailovsky
> wrote:
>> H
June, 2018 00:02:07
> Subject: Re: [ceph-users] fixing unrepairable inconsistent PG
> Can you post the output of a pg query?
>
> On Tue, Jun 19, 2018 at 11:44 PM, Andrei Mikhailovsky
> wrote:
>> A quick update on my issue. I have noticed that while I was trying to move
>> t
A quick update on my issue. I have noticed that while I was trying to move the
problem object on osds, the file attributes got lost on one of the osds, which
is I guess why the error messages showed the no attribute bit.
I then copied the attributes metadata to the problematic object and restar
Hello everyone
I am having trouble repairing one inconsistent and stubborn PG. I get the
following error in ceph.log:
2018-06-19 11:00:00.000225 mon.arh-ibstorage1-ib mon.0 192.168.168.201:6789/0
675 : cluster [ERR] overall HEALTH_ERR noout flag(s) set; 4 scrub errors;
Possible data damage
in your cluster.
> On Mon, Oct 2, 2017 at 4:02 PM Jack < [ mailto:c...@jack.fr.eu.org |
> c...@jack.fr.eu.org ] > wrote:
>> You cannot;
>> On 02/10/2017 21:43, Andrei Mikhailovsky wrote:
>> > Hello everyone,
>>> what is the safes
Hello everyone,
what is the safest way to decrease the number of PGs in the cluster. Currently,
I have too many per osd.
Thanks
___
ceph-users mailing list
ceph-users@lists.ceph.com
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com
Hello everyone,
with the release of Kraken, I was thinking to migrate our existing ceph cluster
to the BlueStore and use the existing journal ssd disks in a cache tier. The
cluster that I have is pretty small, 3 servers with 10 osds each + 2 Intel 3710
SSDs for journals. Each server is also a
Hi Max,
I've played around with ceph on xenserver about 2-3 years ago. I made it work,
but it was all hackish and a lot of manual work. It didn't play well with the
cloud orchestrator and I gave up hoping that either Citrix or Ceph team would
make it work. Currently, I would not recommend usin
Hello fellow cephers,
I have been struggling with stability of my Jewel cluster and from what I can
see I am not the only person.
My setup is: 3 osd+mon servers, 30 osds, half a dozen of client host servers
for rbd access, 40gbit/s infiniband link, all ceph servers are running on
Ubuntu 16.0
Hi Jim,
I've got a few questions for you as it looks like we have a similar cluster for
our ceph infrastructure. A quick overview of what we have. We are also running
a small cluster of 3 storage nodes (30 osds in total) and 5 clients over
40gig/s infiniband link (ipoib). Ever since installin
+1
Ever since upgrading to 10.2.x I have been seeing a lot of issues with our ceph
cluster. I have been seeing osds down, osd servers running out of memory and
killing all ceph-osd processes. Again, 10.2.5 on 4.4.x kernel.
It seems what with every release there are more and more problems with
+1
Ever since upgrading to 10.2.x I have been seeing a lot of issues with our ceph
cluster. I have been seeing osds down, osd servers running out of memory and
killing all ceph-osd processes. Again, 10.2.5 on 4.4.x kernel.
It seems what with every release there are more and more problems with
*BUMP*
> From: "andrei"
> To: "ceph-users"
> Sent: Tuesday, 29 November, 2016 12:46:05
> Subject: [ceph-users] renaming ceph server names
> Hello.
> As a part of the infrastructure change we are planning to rename the servers
> running ceph-osd, ceph-mon and radosgw services. The IP addresses
Hello.
As a part of the infrastructure change we are planning to rename the servers
running ceph-osd, ceph-mon and radosgw services. The IP addresses will be the
same, it's only the server names which will need to change.
I would like to find out the steps required to perform these changes? W
Hi Vincent,
when i did the upgrade, i've done all clients and servers at the same time. No
issue during the upgrade at all. No downtime.
However, when I set the tunables to optimal i've lost all IO to the clients,
which happened gradually, like over a few hours the iowait went from low figure
Hi Orit,
your instructions to the workaround has helped to solve the bucket creation
problems that I had.
again, many thanks for your help
Andrei
- Original Message -
> From: "Orit Wasserman"
> To: "Andrei Mikhailovsky"
> Cc: "Yoann Moulin"
22:02
> Subject: Re: [ceph-users] radosgw - http status 400 while creating a bucket
> On Fri, Nov 11, 2016 at 11:27 PM, Andrei Mikhailovsky
> wrote:
>> Hi Orit,
>>
>> Many thanks. I will try that over the weekend and let you know.
>>
>> Are you sure removing
oup set --rgw-zonegroup=default --default <
> default-zg.json
> 7. radosgw-admin zone set --rgw-zone=default --deault < default-zone.json
> 8. radosgw-admin period update --commit
>
> Good luck,
> Orit
>
> On Thu, Nov 10, 2016 at 7:08 PM, Andrei Mikhailovsky
> wr
while creating a bucket
> Your RGW doesn't think it's the master, and cannot connect to the
> master, thus the create fails.
>
> Daniel
>
> On 11/08/2016 06:36 PM, Andrei Mikhailovsky wrote:
>> Hello
>>
>> I am having issues with creating buckets in rad
-
> From: "Orit Wasserman"
> To: "Andrei Mikhailovsky"
> Cc: "Yoann Moulin" , "ceph-users"
>
> Sent: Thursday, 10 November, 2016 15:22:16
> Subject: Re: [ceph-users] radosgw - http status 400 while creating a bucket
> On Thu, Nov 10,
ks
Andrei
- Original Message -
> From: "Orit Wasserman"
> To: "Andrei Mikhailovsky"
> Cc: "Yoann Moulin" , "ceph-users"
>
> Sent: Thursday, 10 November, 2016 13:58:32
> Subject: Re: [ceph-users] radosgw - http status 400 while creat
"id": "default",
"name": "default",
"domain_root": ".rgw",
"control_pool": ".rgw.control",
"gc_pool": ".rgw.gc",
"log_pool": ".log",
"intent_log_pool"
both services before running
the script. I will run it again to make sure.
Andrei
- Original Message -
> From: "Orit Wasserman"
> To: "Andrei Mikhailovsky"
> Cc: "Yoann Moulin" , "ceph-users"
>
> Sent: Thursday, 10 November, 2
"hostnames": [],
>>> "hostnames_s3website": [],
>>> "master_zone": "",
>>> "zones": [
>>> {
>>> "id": "default",
>>> "name": "d
***bump***
this is pretty broken and urgent. thanks
- Original Message -
> From: "Andrei Mikhailovsky"
> To: "Yoann Moulin"
> Cc: "ceph-users"
> Sent: Wednesday, 9 November, 2016 23:27:17
> Subject: Re: [ceph-users] radosgw - http s
{
>> "id": "default",
>> "name": "default",
>> "endpoints": [],
>> "log_meta": "false",
>> "log_data": "false",
&
[]
}
],
"default_placement": "default-placement",
"realm_id": ""
}
The strange thing as you can see, following the "radosgw-admin period update
--commit" command, the master_zone and the realm_id values reset to blank
- Original Message -
> From: "Yehuda Sadeh-Weinraub"
> To: "Andrei Mikhailovsky"
> Cc: "ceph-users"
> Sent: Wednesday, 9 November, 2016 01:13:48
> Subject: Re: [ceph-users] radosgw - http status 400 while creating a bucket
> On Tue, No
uot;name": "default-placement",
"tags": []
}
],
"default_placement": "default-placement",
"realm_id": "5b41b1b2-0f92-463d-b582-07552f83e66c"
}
As you can see, the master_zone is now set to defa
_log_pool": ".usage",
"user_keys_pool": ".users",
"user_email_pool": ".users.email",
"user_swift_pool": ".users.swift",
"user_uid_pool": ".users.uid",
"system_key": {
&
Hello
I am having issues with creating buckets in radosgw. It started with an upgrade
to version 10.2.x
When I am creating a bucket I get the following error on the client side:
boto.exception.S3ResponseError: S3ResponseError: 400 Bad Request
InvalidArgumentmy-new-bucket-31337tx000
ft",
"user_uid_pool": ".users.uid",
"system_key": {
"access_key": "",
"secret_key": ""
},
"placement_pools": [
{
"key": "default-placement",
g the config migration
> alluded to in that thread? I'm reluctant to do anything to the
> still-working 0.94.9 gateway until I can get the 10.2.3 gateways working!
>
> Graham
>
> On 10/05/2016 04:23 PM, Andrei Mikhailovsky wrote:
>> Hello everyone,
>>
>&
Hello everyone,
I've just updated my ceph to version 10.2.3 from 10.2.2 and I am no longer able
to start the radosgw service. When executing I get the following error:
2016-10-05 22:14:10.735883 7f1852d26a00 0 ceph version 10.2.3
(ecc23778eb545d8dd55e2e4735b53cc93f92e65b), process radosgw, pi
Hello
I've got a small cluster of 3 osd servers and 30 osds between them running
Jewel 10.2.2 on Ubuntu 16.04 LTS with stock kernel version 4.4.0-34-generic.
I am experiencing rather frequent osd crashes, which tend to happen a few times
a month on random osds. The latest one gave me the foll
Gregory,
I've been given a tip by one of the ceph user list members on tuning values and
data migration and cluster IO. I had an issues twice already where my vms would
simply loose IO and crash while the cluster is being optimised for the new
tunables.
The recommendations were to upgrade the
P addresses of cluster
> members
> On 16-07-22 13:33, Andrei Mikhailovsky wrote:
>> Hello
>> We are planning to make changes to our IT infrastructure and as a result the
>> fqdn and IPs of the ceph cluster will change. Could someone suggest the best
>> way of dealing
Hello
We are planning to make changes to our IT infrastructure and as a result the
fqdn and IPs of the ceph cluster will change. Could someone suggest the best
way of dealing with this to make sure we have a minimal ceph downtime?
Many thanks
Andrei
Hello again
Any thoughts on this issue?
Cheers
Andrei
> From: "Andrei Mikhailovsky"
> To: "ceph-users"
> Sent: Wednesday, 22 June, 2016 18:02:28
> Subject: [ceph-users] Error EPERM when running ceph tell command
> Hi
> I am trying to run an osd
Hi
I am trying to run an osd level benchmark but get the following error:
# ceph tell osd.3 bench
Error EPERM: problem getting command descriptions from osd.3
I am running Jewel 10.2.2 on Ubuntu 16.04 servers. Has the syntax change or do
I have an issue?
Cheers
Andrei
__
warbrick"
> To: "ceph-users"
> Cc: "ceph-devel"
> Sent: Wednesday, 22 June, 2016 17:09:48
> Subject: Re: [ceph-users] cluster down during backfilling, Jewel tunables and
> client IO optimisations
> On 22/06/16 17:54, Andrei Mikhailovsky wrote:
>>
Hi Daniel,
Many thanks for your useful tests and your results.
How much IO wait do you have on your client vms? Has it significantly increased
or not?
Many thanks
Andrei
- Original Message -
> From: "Daniel Swarbrick"
> To: "ceph-users"
> Cc: "ceph-devel"
> Sent: Wednesday, 22 June
seemed to be OK.
>> > At this stage, I have a strong suspicion that it is the introduction of
>> > "require_feature_tunables5 = 1" in the tunables. This seems to require
>> > all RADOS connections to be re-established.
>> Do you have any evidence of tha
it and it slowly started to increase over the
course of about an hour. At the end, there was 100% iowait on all vms. If this
was the case, wouldn't I see iowait jumping to 100% pretty quickly? Also, I
wasn't able to start any of my vms until i've rebooted one of my osd / mon
server
IP Interactive UG ( haftungsbeschraenkt )
> Zum Sonnenberg 1-3
> 63571 Gelnhausen
>
> HRB 93402 beim Amtsgericht Hanau
> Geschäftsführung: Oliver Dzombic
>
> Steuer Nr.: 35 236 3622 1
> UST ID: DE274086107
>
>
> Am 18.06.2016 um 18:04 schrieb Andrei Mikhailovsky:
>
Hello ceph users,
I've recently upgraded my ceph cluster from Hammer to Jewel (10.2.1 and then
10.2.2). The cluster was running okay after the upgrade. I've decided to use
the optimal tunables for Jewel as the ceph status was complaining about the
straw version and my cluster settings were not
"ceph", MODE="660"
So, it looks as all /dev/sd** (including partition numbers) which has the model
attribute INTEL SSDSC2BA20 and changes the ownership. You might want to adjust
your model number for the ssd journals.
Andrei
> From: "Ernst Pijper"
> To: &
Interesting,
I've switched to jemalloc about a month ago while running Hammer. after
installing the library and using the /etc/ld.so.preload I am seeing that all
ceph-osd processes are indeed using the library. I've upgraded to Jewel a few
days ago and see the same picture:
# time lsof |grep c
Hi Anthony,
>
>> 2. Inefficient chown documentation - The documentation states that one should
>> "chown -R ceph:ceph /var/lib/ceph" if one is looking to have ceph-osd ran as
>> user ceph and not as root. Now, this command would run a chown process one
>> osd
>> at a time. I am considering my c
Hello
I've recently updated my Hammer ceph cluster running on Ubuntu 14.04 LTS
servers and noticed a few issues during the upgrade. Just wanted to share my
experience.
I've installed the latest Jewel release. In my opinion, some of the issues I
came across relate to poor upgrade documentatio
Hello,
I am planning to make some changes to our ceph cluster and would like to ask
the community of the best route to take.
Our existing cluster is made of 3 osd servers (two of which are also mon
servers) and the total of 3 mon servers. The cluster is currently running on
Ubuntu 14.04.x LT
Hello everyone,
Please excuse me if this topic has been covered already. I've not managed to
find a guide, checklist or even a set of notes on optimising OS level
settings/configuration/services for running ceph. One of the main reasons for
asking is I've recently had to troubleshoot a bunch o
hat else I could try, please let me know.
>
> Andrei
>
> - Original Message -
>> From: "Wido den Hollander"
>> To: "andrei"
>> Cc: "ceph-users"
>> Sent: Tuesday, 26 April, 2016 22:18:37
>> Subject: Re: [ceph-users
riginal Message -
> From: "Wido den Hollander"
> To: "andrei"
> Cc: "ceph-users"
> Sent: Tuesday, 26 April, 2016 22:18:37
> Subject: Re: [ceph-users] Hammer broke after adding 3rd osd server
>> Op 26 april 2016 om 22:31 schreef Andrei Mikhailovsky
is also OK."? By
clients do you mean the host servers?
Many thanks
Andrei
- Original Message -
> From: "Wido den Hollander"
> To: "ceph-users" , "Andrei Mikhailovsky"
>
> Sent: Tuesday, 26 April, 2016 21:17:59
> Subject: Re: [ceph-users] H
Hello everyone,
I've recently performed a hardware upgrade on our small two osd server ceph
cluster, which seems to have broke the ceph cluster. We are using ceph for
cloudstack rbd images for vms.All of our servers are Ubuntu 14.04 LTS with
latest updates and kernel 4.4.6 from ubuntu repo.
Hi all,
Was wondering what is the best way to add a new osd server to the small ceph
cluster? I am interested in minimising performance degradation as the cluster
is live and actively used.
At the moment i've got the following setup:
2 osd servers (9 osds each)
Journals on Intel 520/530 ss
I've done the ceph osd reweight-by-utilization and it seems to have solved the
issue. However, not sure if this will be the long term solution.
Thanks for your help
Andrei
- Original Message -
> From: "Shinobu Kinjo"
> To: "Andrei Mikhailovsky"
> Cc
thanks for pointing it out.
Cheers
Andrei
- Original Message -
> From: "Christian Balzer"
> To: "ceph-users"
> Cc: "Andrei Mikhailovsky"
> Sent: Wednesday, 6 April, 2016 04:36:30
> Subject: Re: [ceph-users] rebalance near full osd
>
Hi
I've just had a warning ( from ceph -s) that one of the osds is near full.
Having investigated the warning, i've located that osd.6 is 86% full. The data
distribution is nowhere near to being equal on my osds as you can see from the
df command output below:
/dev/sdj1 2.8T 2.4T 413G 86% /v
Hi Eric,
I remember having very similar issue when I was setting up radosgw. It turned
out to be the issue on the proxy server side and not the radosgw. After trying
a different proxy server the problem has been solved. Perhaps you have the same
issue.
Andrei
> From: "Eric Magutu"
> To: "
From: "Tyler Bishop"
> To: "Lionel Bouton"
> Cc: "Andrei Mikhailovsky" , "ceph-users"
>
> Sent: Tuesday, 22 December, 2015 16:36:21
> Subject: Re: [ceph-users] Intel S3710 400GB and Samsung PM863 480GB fio
> results
> Write endur
Hello guys,
I was planning to upgrade our ceph cluster over the holiday period and was
wondering when are you planning to release the next point release of the
Infernalis? Should I wait for it or just roll out 9.2.0 for the time being?
thanks
Andrei
Hello guys,
Was wondering if anyone has done testing on Samsung PM863 120 GB version to see
how it performs? IMHO the 480GB version seems like a waste for the journal as
you only need to have a small disk size to fit 3-4 osd journals. Unless you get
a far greater durability.
I am planning to r
follow the procedure
on the second osd server.
Do you think this could work?
Performance wise, i do not have a great IO demand, in particular over a
weekend.
Thanks
Andrei
- Original Message -
From: "Luis Periquito"
To: "Andrei Mikhailovsky"
Cc: "ceph-us
Any thoughts anyone?
Is it safe to perform OS version upgrade on the osd and mon servers?
Thanks
Andrei
- Original Message -
From: "Andrei Mikhailovsky"
To: ceph-us...@ceph.com
Sent: Tuesday, 20 October, 2015 8:05:19 PM
Subject: [ceph-users] ceph and upgrading
Hello guys,
I've upgraded to the latest Hammer release and I've just noticed a massive
issue after the upgrade (((
I am using ceph for virtual machine rbd storage over cloudstack. I am having
issues with starting virtual routers. The libvirt error message is:
cat r-1407-VM.log
2015-10-21
Same here, the upgrade went well. So far so good.
- Original Message -
From: "Francois Lafont"
To: "ceph-users"
Sent: Tuesday, 20 October, 2015 9:14:43 PM
Subject: Re: [ceph-users] v0.94.4 Hammer released
Hi,
On 20/10/2015 20:11, Stefan Eriksson wrote:
> A change like this b
Hello everyone
I am planning to upgrade my ceph servers from Ubuntu 12.04 to 14.04 and I am
wondering if you have a recommended process of upgrading the OS version without
causing any issues to the ceph cluster?
Many thanks
Andrei
___
ceph-users
Hello
I've recently upgraded my ceph cluster from 0.94.1 to 0.94.3 and noticed that
after about a day i started getting the emails from our network/host monitoring
system. The notifications were that there are too many processes on the osd
servers. I've not seen this before and I am running ce
Hi Nick,
I've played with Flashcache and EnhanceIO, but I've decided not to use it for
production in the end. The reason was that using both has increased the amount
of slow requests that I had on the cluster and I have also noticed somewhat
higher level of iowait on the vms. At that time, I d
Thanks Mate, I was under the same impression.
Could someone at Inktank please help us with this problem? Is this intentional
or has it simply been an error?
Thanks
Andrei
--
Andrei Mikhailovsky
Director
Arhont Information Security
Web: http://www.arhont.com
http://www.wi-foo.com
Hi,
I seem to be missing the latest Hammer release 0.94.2 in the repo for Ubuntu
precise. I can see the packages for trusty, but precise still shows 0.94.1. Is
there a miss or did you stop supporting precise? Or perhaps something is odd
happened with my precise servers?
Cheers
Andrei
sense to get a small battery
protected raid card in front of the 520s and 530s to protect against these
types of scenarios?
Cheers
- Original Message -
> From: "Mark Nelson"
> To: "Andrei Mikhailovsky"
> Cc: ceph-users@lists.ceph.com
> Sent: Friday, 19 Jun
19 June, 2015 3:59:55 PM
> Subject: Re: [ceph-users] rbd performance issue - can't find bottleneck
>
>
>
> On 06/19/2015 09:54 AM, Andrei Mikhailovsky wrote:
> > Hi guys,
> >
> > I also use a combination of intel 520 and 530 for my journals and have
> >
Hi guys,
I also use a combination of intel 520 and 530 for my journals and have noticed
that the latency and the speed of 520s is better than 530s.
Could someone please confirm that doing the following at start up will stop the
dsync on the relevant drives?
# echo temporary write through > /s
Piotr,
You may also investigate if the cache tier made of a couple of ssds could help
you. Not sure how the data is used in your company, but if you have a bunch of
hot data that moves around from one vm to another it might greatly speed up the
rsync. On the other hand, if a lot of rsync data i
Anthony,
I doubt the manufacturer reported 315MB/s for 4K block size. Most likely
they've used 1M or 4M as the block size to achieve the 300MB/s+ speeds
Andrei
- Original Message -
> From: "Alexandre DERUMIER"
> To: "Anthony Levesque"
> Cc: "ceph-users"
> Sent: Saturday, 25 April,
Hi
I have been testing the Samsung 840 Pro (128gb) for quite sometime and I can
also confirm that this drive is unsuitable for osd journal. The performance and
latency that I get from these drives (according to ceph osd perf) are between
10 - 15 times slower compared to the Intel 520. The Inte
1 - 100 of 265 matches