I am using LOCTITE 416 - Net wt. 1 OZ.(Part No. 41650) along with the
LOCTITE ACCELERATOR 7452 (Part No. 18637) net. WT.0.70 OZ and works well for
Thermocouples AWG 30. (5-8 seconds)
Respectfully yours,
Constantin
Constantin Bolintineanu P.Eng.
DIGITAL SECURITY CONTROLS LTD.
3301 LANGSTAFF Road
of
80.00 USD / bottle; it has 100 tablets with a burning time of 130 seconds;
Orders shall be FAXED at 317 895 9340.
Respectfully yours,
Constantin
Constantin Bolintineanu P.Eng.
DIGITAL SECURITY CONTROLS LTD.
3301 LANGSTAFF Road, L4K 4L2
CONCORD, ONTARIO, CANADA
e-mail: cbolintine...@dsc.com
,
Constantin
Constantin Bolintineanu P.Eng.
DIGITAL SECURITY CONTROLS LTD.
3301 LANGSTAFF Road, L4K 4L2
CONCORD, ONTARIO, CANADA
e-mail: cbolintine...@dsc.com
Telephone: 905 760 3000 ext 2568
Fax: 905 760 3020
-Original Message-
From: Brian McAuliffe [mailto:i...@mcac.ie]
Sent: Wednesday, August 21
To a such a REPLY, . NO COMMENTS...
Constantin
Constantin Bolintineanu P.Eng.
DIGITAL SECURITY CONTROLS LTD.
3301 LANGSTAFF Road, L4K 4L2
CONCORD, ONTARIO, CANADA
e-mail: cbolintine...@dsc.com
Telephone: 905 760 3000 ext 2568
Fax: 905 760 3020
-Original Message-
From: Garry Hojan
AND French.
Respectfully yours,
Constantin
Constantin Bolintineanu P.Eng.
DIGITAL SECURITY CONTROLS LTD.
3301 LANGSTAFF Road, L4K 4L2
CONCORD, ONTARIO, CANADA
e-mail: cbolintine...@dsc.com
Telephone: 905 760 3000 ext 2568
Fax: 905 760 3020
-Original Message-
From: Peter Merguerian
, the WARNINGS were Not Applicable. I
hope it helps.
I understood that Kris observed on the PS a WARNING in English ONLY, which
does not fulfil all of the applicable requirements of the used Standard.
Respectfully yours,
Constantin
Constantin Bolintineanu P.Eng.
DIGITAL SECURITY CONTROLS LTD
be useful.
Respectfully yours,
Constantin
Constantin Bolintineanu P.Eng.
TEPG - DIGITAL SECURITY CONTROLS LTD.
3301 LANGSTAFF Road, L4K 4L2
CONCORD, ONTARIO, CANADA
e-mail: cbolintine...@tycoint.com
telephone: 905 760 3000 ext 2568
Visit our web site at www.tycofss.com
-Original Message
.
Happy Holidays to all of my VERY PROFESSIONAL COLLEAGUES OF THE MOST
PROFESSIONAL AND ELEGANT DISCUSSION GROUP!
HAPPY NEW YEAR and HAVE A VERY SAFE AND PROSPEROUS 2002!
Respectfully yours,
Constantin
Constantin Bolintineanu P.Eng.
TEPG - DIGITAL SECURITY CONTROLS LTD.
3301 LANGSTAFF Road, L4K
not comment any of the
referees decisions. It will make the difference between us, and others.
I would suggest to close this subject and to continue our discussions on emc
and pstc.
Have a great weekend everybody. The Life is beautiful ! Enjoy it!
Respectfully yours,
Constantin
Constantin Bolintineanu
Dear Colleagues,
One year ago I put together some information regarding this subject; (I have
as well the Bibliography for it).
In my opinion, all the participants at this discussion, made very useful
observations.
Respectfully yours,
Constantin
Constantin Bolintineanu P.Eng.
DIGITAL
http://www.iec.ch/webstore/
Respectfully yours,
Constantin
Constantin Bolintineanu P.Eng.
DIGITAL SECURITY CONTROLS LTD.
3301 LANGSTAFF Road, L4K 4L2
CONCORD, ONTARIO, CANADA
e-mail: bolin...@dscltd.com
telephone: 905 760 3000 ext 2568
Visit our web site at www.dscgrp.com
-Original
NIST issued FIPS(Federal Information Processing Standard) 140-2 (which
supersedes FIPS 140-1);
The Title of the subject Standard is Security requirements for
Cryptographic Modules; It was issued in 1999.
Respectfully yours,
Constantin
Constantin Bolintineanu P.Eng.
DIGITAL SECURITY CONTROLS
Dear Doug,
0 means 600 and greater
1 between 400 and up to 600
2 between 250 and up to 400
3 between 175 and up to 250
4 between 100 and up to 175
5 less than 100
I hope it helps. You may find more details on the UL website.
Respectfully yours,
Constantin
Constantin Bolintineanu P.Eng
for insulation in the PRIMARY circuit.
Respectfully yours,
Constantin
Constantin Bolintineanu P.Eng.
DIGITAL SECURITY CONTROLS LTD.
3301 LANGSTAFF Road, L4K 4L2
CONCORD, ONTARIO, CANADA
e-mail: bolin...@dscltd.com
telephone: 905 760 3000 ext 2568
www.dscgrp.com
-Original Message-
From
are working for?...
I did not see any information regarding this subject on ITL websitenor
accreditation.
Any information on this subject is very much appreciated.
Respectfully yours,
Constantin
Constantin Bolintineanu P.Eng.
DIGITAL SECURITY CONTROLS LTD.
3301 LANGSTAFF Road, L4K 4L2
CONCORD
purposes.)
Respectfully yours,
Constantin
Constantin Bolintineanu P.Eng.
DIGITAL SECURITY CONTROLS LTD.
3301 LANGSTAFF Road, L4K 4L2
CONCORD, ONTARIO, CANADA
e-mail: bolin...@dscltd.com
telephone: 905 760 3000 ext 2568
www.dscgrp.com
-Original Message-
From: geor...@lexmark.com
not specify the above
mentioned aspect as a CRITERIA for acceptance,(just to do not be consumed
completely...) and thus, in my engineering judgement, since the rest of the
criteria are identical, I think that both, 5VA and 5VB will comply with 5V.
Respectfully yours,
Constantin
Constantin Bolintineanu
for at least 48 hours.
It is an insulating material as well.
I hope it helps.
Respectfully yours,
Constantin
Constantin Bolintineanu P.Eng.
DIGITAL SECURITY CONTROLS LTD.
3301 LANGSTAFF Road, L4K 4L2
CONCORD, ONTARIO, CANADA
e-mail: bolin...@dscltd.com
telephone: 905 760 3000 ext 2568
www.dscgrp.com
. Some conditions apply...
I hope it helps.
Respectfully yours,
Constantin
Constantin Bolintineanu, P.Eng
Senior Safety Specialist
DIGITAL SECURITY CONTROLS LTD.
3301 LANGSTAFF Rd. CONCORD, ONTARIO, CANADA, L4K 4L2
Phone: 1-905 760 3000 extension 2568
Fax: 1-905 760 3020 APPROVAL SERVICES
E-mail
versichern = to assure, to make secure (which one will fit your specs)
errichten = to establish, to set-up
Best regards,
Constantin
Constantin Bolintineanu, P.Eng
Senior Safety Specialist
DIGITAL SECURITY CONTROLS LTD.
3301 LANGSTAFF Rd. CONCORD, ONTARIO, CANADA, L4K 4L2
Phone: 1-905 760 3000
and Voltage, Electric Strength
Test, Insulation Resistance, etc.)
Respectfully yours,
Constantin
Constantin Bolintineanu, P.Eng
Senior Safety Engineer
DIGITAL SECURITY CONTROLS LTD.
3301 LANGSTAFF Rd. CONCORD, ONTARIO, CANADA, L4K 4L2
Phone: 1-905 760 3000 extension 2568
Fax: 1-905 760 3020 APPROVAL
your product will also have to
comply with electromagnetic compatibility requirements, probably of AS/NZS
3548, which is similar to CISPR 22. Again, full details can be obrtained
from the ACA.
I hope it helps.
Respectfully yours,
Constantin
Constantin Bolintineanu, P.Eng
Senior Safety
EDD
contact Mr. PATRICK S. McGEE Phone 919 469 9434 OR 1 800 806 6236 Fax 919
469 5743,
2200 Gateway Centre Blvd. Suite 215, Morrisville, NC, 27560, US.
e-mail: prodsaf...@aol.com
-Original Message-
From: jim_bac...@mail.monarch.com [mailto:jim_bac...@mail.monarch.com]
Sent: Tuesday,
.
I hope it helps in some respect.
Respectfully yours,
Constantin
Constantin Bolintineanu, P.Eng.
Product Safety Engineer
DIGITAL SECURITY CONTROLS LTD.
3301 LANGSTAFF Rd. CONCORD, ONTARIO, CANADA, L4K 4L2
Phone: 1-905 760 3000 extension 2568
Fax: 1-905 760 3020 APPROVAL SERVICES
E-mail: bolin
,
Controlling and Related Equipment the ANSI Standard ANSI/ISA-S82.01-1994
which is [as UL3101-1] a Harmonized Standard to IEC 1010-1.
Respectfully yours,
Constantin
Constantin Bolintineanu, P.Eng.
Product Safety Engineer
DIGITAL SECURITY CONTROLS LTD.
1645 FLINT Rd. TORONTO , ONTARIO, CANADA M3J
with EN60950.
I think that is not too much place for interpretationDECLARED AS
COMPLYING WITH EN60950all comments will be appreciated regarding this
matter.
Respectfully yours,
Constantin
The opinions expressed are my own and not necessarily those of my employer.
Constantin Bolintineanu
The Standard is: INFORMATION TECHNOLOGY EQUIPMENT. ROUTINE ELECTRICAL SAFETY
TESTING IN PRODUCTION. The number is EN50116:1996
Respectfully yours,
Constantin Bolintineanu
Constantin Bolintineanu, P.Eng.
Product Safety Engineer
DIGITAL SECURITY CONTROLS LTD.
1645 FLINT Rd. TORONTO , ONTARIO, CANADA
NRTL Labs,
you have the right to ask the same LAB to perform the following steps in
order to obtain the Canadian Certification based on the previous Report,
Initial Plant inspection, Labeling agreement, etc.
Respectfully yours,
Constantin Bolintineanu P.Eng.
Product Safety Engineer
DIGITAL SECURITY
for a higher
class of laser products...
Respectfully yours,
Constantin Bolintineanu P.Eng.
Product Safety Engineer
bolin...@dscltd.com
The opinions expressed are my own and not necessarily those of my
employer.
-Original Message-
From: Crabb, John [SMTP:jo...@exchange.scotland.ncr.com]
Sent
in which the equipment is to be installed. (references
should be made to Clause 1.7.14 EN60950...)
I think that this is your situation and the conformity assessment with
the letter of the Standard will not cover the Manufacturer's
liability
I hope it helps...
Respectfully yours,
Constantin
The address for the CENELEC website is :
http://server.cenelec.be:8100/cenelechtml/index.htm
Respectfully yours,
Constantin Bolintineanu
Product Safety Engineer
bolin...@dscltd.com
-Original Message-
From: grant.pi...@adn.alcatel.com [SMTP:grant.pi...@adn.alcatel.com]
Sent
Equipment having a specified function and interconnected by
coupling and/or multiple portable socket-outlet.),
2.
Due to the National Deviations , yes , you will find differences
between those Standards.
Respectfully yours,
Constantin Bolintineanu
Product Safety Engineer
bolin...@dscltd.com
which includes the Standard EN 60825-1 + corr.Feb
1995+A11+corr.July 1997
Respectfully yours,
Constantin Bolintineanu
Product Safety Engineer
bolin...@dscltd.com
The opinions expressed are my own and not necessarily those of my
employer.
-Original Message-
From: jly...@gtech.com [SMTP:jly
WORLDLAB
(967-5352) for the nearest location.
Constantin Bolintineanu P.Eng
Product Safety Engineer
bolin...@dscltd.com
The opinions expressed are my own and not necessarily those of my
employer.
-Original Message-
From: Rich Nute [SMTP:ri...@sdd.hp.com]
Sent: Tuesday, June 23, 1998 1:11 PM
34 matches
Mail list logo