ph-telecom.com]
Sent: Friday, March 16, 2012 4:57 PM
To: EMC-PSTC@LISTSERV.IEEE.ORG
Subject: Re: [PSES] Safety standard for PBX telephone system??
On 3/16/2012, Ken Wyatt wrote:
Thanks everybody! I wasn't sure if I had to be looking at the telecom/NEBS
standards.
Hi Ken:
The Telcordia
On 3/16/2012, Ken Wyatt wrote:
Thanks everybody! I wasn't sure
if I had to be looking at the telecom/NEBS standards.
Hi Ken:
The Telcordia NEBS requirements are not regulatory requirements, although
they often get lumped into lists of "regulatory"
requirements.
The NEBS requirements are really
Thanks everybody! I wasn't sure if I had to be looking at the telecom/NEBS
standards. I appreciate all the advice!
Have a great weekend everyone.
Ken
___
Kenneth Wyatt
Wyatt Technical Services LLC
Woodland Park, CO
Email Me! | Web Site | Blog
Subscribe to Newsletter
Connect w
> From: Brian Oconnell
> Sent: Friday, March 16, 2012 14:49
>
> And Peter Tarver would say to also look at TR62102.
I'm special that way.
Now if you'll excuse me, I have to put on my helmet (it has shiny new tin
foil today!) and ride the little yellow bus to where the nice lady gives
us cookies.
A rather obscure 'boutique' standard can be used -> 60950-1.
And Peter Tarver would say to also look at TR62102.
-Original Message-
From: emc-p...@ieee.org [mailto:emc-p...@ieee.org]On Behalf Of Ken Wyatt
Sent: Friday, March 16, 2012 2:22 PM
To: EMC-PSTC@LISTSERV.IEEE.ORG
Subject: Safety
On 3/16/2012, Ken Wyatt wrote:
Does anyone know the appropriate
US/Canadian/EU/International product safety standard(s) for a typical PBX
telephone system as might be used in a small business or hotel?
Hi Ken:
I normally use UL/CSA 60950 (Information Technology Equipment) for the
USA and the var
Hi Group,
Does anyone know the appropriate US/Canadian/EU/International product safety
standard(s) for a typical PBX telephone system as might be used in a small
business or hotel?
Thanks in advance, Ken
___
Kenneth Wyatt
Wyatt Technical Services LLC
Woodland Park, CO
Email
7 matches