RE: SONET ESD performance

2001-07-27 Thread Gary McInturff
take several seconds for it to re-establish and some routing information may have to be re-learned). Gary -Original Message- From: Doug McKean [mailto:dmck...@corp.auspex.com] Sent: Friday, July 27, 2001 8:03 AM To: EMC-PSTC Discussion Group Subject: Re: SONET ESD performance I beg to

Re: SONET ESD performance

2001-07-27 Thread Doug McKean
I beg to disagree. I have reservations about "no error" criteria. That's imposing a far greater restriction on equipment than Criteria A for immunity. Now granted the immunity standards are in a different spirit than the Bellcore Standards. But, it would seem as though the errored second is mor

RE: SONET ESD performance

2001-07-26 Thread George Stults
rge Stults [own opinions only] -Original Message- From: Martin Garwood [mailto:mgarw...@approvalspecialists.com] Sent: Wednesday, July 25, 2001 8:01 PM To: Scott Lemon; emc-p...@majordomo.ieee.org Subject: Re: SONET ESD performance Scott, The permissible errors rela

Re: SONET ESD performance

2001-07-26 Thread Doug McKean
Debatable in my experience which is not a lot. There's two totally different standards for errors. One's a bit error limit and the other is a time errored limit. An errored second can have any amount of errors during that second. It's not a bit error limit. It's a time errored limit. Bu

Re: SONET ESD performance

2001-07-26 Thread Martin Garwood
sday, July 25, 2001 11:43 AM Subject: SONET ESD performance > > Hi group, > I am looking for guidance with respect to allowable "service-affecting > responses" for a SONET system (e.g. OC-48) when tested to GR-1089 ESD > immunity requirements. GR-1089 R2-3 states that &qu

Re: SONET ESD performance

2001-07-25 Thread Douglas C. Smith
Hi Scott and the group, Just a thought... If the equipment you are testing responds unfavorably to something the environment, it does not matter that you pass GR-1089. And, I have seen lots of stuff that affected lightwave equipment not covered under 1089 that got the operating companies pretty u

SONET ESD performance

2001-07-25 Thread Scott Lemon
Hi group, I am looking for guidance with respect to allowable "service-affecting responses" for a SONET system (e.g. OC-48) when tested to GR-1089 ESD immunity requirements. GR-1089 R2-3 states that "service-affecting responses, unless within system operating limits,...shall not occur." Para. 2.3