Re: [PSES] Seismic requirements- Euro Machinery Directive

2014-11-25 Thread Canio Dichirico
Hi! Sad enough to say, Italy regularly undergoes earthquakes with casualties and/or damages to structures with a period of about 10 to 20 years. That without forgetting that Greece is also a EU member. Kind regards Canio Dichirico ESO www.eso.orghttp://www.eso.org Germany P.S. Mt Aetna has

Re: [PSES] Mains voltage in Europe

2012-03-21 Thread Canio Dichirico
Dear All, Some comments of mine embedded in the message below. Kind regards Canio Dichirico -Original Message- From: emc-p...@ieee.org [mailto:emc-p...@ieee.org] On Behalf Of John Cotman Sent: 21 March 2012 10.50 To: EMC-PSTC@LISTSERV.IEEE.ORG Subject

RE: Low Smoke Halogen Free Cables

2003-05-19 Thread Canio Dichirico
Toxicity Index is used, etc., etc. I hope this helps! Cheers Canio Dichirico European Southern Observatory Technical Division Electronic Systems Department Karl-Schwarzschild-Str. 2 D-85748 Gaching bei München Tel. +49-(0)89-3200 6500 Fax. +49-(0)89-3200 6694 Email cdich...@eso.org

Re: 230 Vac or 240 Vac?

2001-02-13 Thread Canio Dichirico
, transmission, primary distribution, secondary distribution). 2. However why are the European utilities still so late in adopting 400 VAC? Who has any replies or comments? TIA Canio Dichirico European Southern Observatory Technical Division - Electronic Systems Department Karl-Schwarzschild-Str. 2 D

Re: EN 60439-1 ???

2001-01-12 Thread Canio Dichirico
hope this help. Regards. Canio Dichirico European Southern Observatory Technical Division - Electronic Systems Department Karl-Schwarzschild-Str. 2 D-85748 Garching bei München Tel./Fax +49-89-3200 6500 Fax +49-89-3200 6694 email: cdich...@eso.org website: www.eso.org

Voltage Fluctuation (flicker) limits acc. to IEEE Std. 519

2000-10-16 Thread Canio Dichirico
edition, 1990-05. Am I right? If yes, how do the two standards compare? Thank you for your attention! Canio Dichirico European Southern Observatory Technical Division - Electronic Systems Department Karl-Schwarzschild-Str. 2 D-85748 Garching bei München Tel./Fax +49-89-3200 6500 Fax +49-89-320 23 62

power line filters in the range 50 MHz to 12 GHz

2000-09-20 Thread canio dichirico
in advance! Canio Dichirico European Southern Observatory Technical Division - Electronic System Department Karl-Schwarzschild-Str. 2 D-85748 Garching bei Muenchen Germany Tel./Fax +49-89-3200 6500 Fax. +49-89-320 23 62 email: cdich...@eso.org website: www.eso.org

Re: Voltage Breakdown

2000-07-12 Thread Canio Dichirico
drei Groschen interpretation of IEEE Std. 142-1991. Cheers! Canio Dichirico European Southern Observatory Technical Division - Electronic Systems Department Karl-Schwarzschild-Str. 2 D-85748 Garching bei München Tel./Fax +49-89-3200 6500 Fax +49-89-320 23 62 email: cdich...@eso.org website

Fw: Is the modular approach to EMC the same as CE+CE = CE?

2000-03-28 Thread Canio Dichirico
reply of yours to my message? I would really appreciate. Canio Dichirico - Original Message - From: Canio Dichirico To: IEEE EMC List Sent: Monday, March 27, 2000 14:30 Subject: Is the modular approach to EMC the same as CE + CE = CE? Hi All! The designer/manufacturer of a (prototype

Is the modular approach to EMC the same as CE + CE = CE?

2000-03-27 Thread Canio Dichirico
are the differences, if any, between the modular approach and the equation CE + CE = CE? I remember reading in this forum (plenty of times) that CE + CE does not necessarily equal CE. Any replies or comments are welcome. Thank you all in advance! Canio Dichirico European Southern Observatory

Re: A modest proposal.

2000-03-27 Thread Canio Dichirico
to me. With an Italian spelling I would write: Enof is tu mac! ;-) Thank you all for contributing to my knowledge of both EMC/Safety and English. Canio Dichirico - Original Message - From: Lou Gnecco l...@tempest-inc.com To: emc-p...@ieee.org Sent: Sunday, March 26, 2000 03:14 Subject

EMC and product safety split?

2000-03-15 Thread Canio Dichirico
I fully agree! Canio Dichirico European Southern Observatory Technical Division - Electronic Systems Department Karl-Schwarzschild-Str. 2 D-85748 Garching bei München Tel. +49-89-3200 6500 Fax +49-89-320 23 62 email: cdich...@eso.org www.eso.org

Re: Doubt on household equipment interference

1999-09-03 Thread Canio Dichirico
the point of common coupling should be my apartment panelboard. ... a doubt ... Should I expect any interference at all on my TV? Both my blender and my TV are CE-marked ... Bis Montag! (i.e., I will report on next Monday) Canio Dichirico - Original Message - From: James, Chris c

Re: 89/336/EEC VS 89/336/EWG EWG??

1998-08-13 Thread Canio Dichirico
for the newly born Directives. To this end check http://europa.eu.int/eur-lex/ Regards. Canio Dichirico ESO VLT Division, Hardware Group, Electrical and EMC Engineer Tel.: +49-89-3200-6500 temporarily at ESO VLT Observatory, Cerro Paranal, Facility Department Tel.: +56-55-281291, ext. 5116; FAX +56

Re: AC Mains Termination

1998-07-10 Thread Canio Dichirico
sides of the Atlantic?). Only a bit of patience is needed to get used to the different jargons ... Thank you from a low frequency member for any answer he would get! Canio Dichirico -Original Message- From: Jim Eichner jeich...@statpower.com To: 'IEEE PSTC' emc-p...@ieee.org List-Post: emc