Re: list of cobol load modules and their cobol version

2017-08-07 Thread Nick
I can offer you a utility type program It "reads" in a PDS/PDSE containing load modules/program objects and it uses the DESERV and IEWBIND API"s to list all csects in the objects and what compiler/product was used to build it. This what your looking for? Shout if it is and I can mail you either

Re: IXGBRWSE - SMF Logstream

2013-11-18 Thread Nick Jones
not supported by IBM. In some cases the data returned by the log stream browse has to be manipulated by SMF before the user sees it, such as if zEDC compression is turned on in z/OS V2R1. -Nick Jones z/OS Development

Re: Need to move some DASD volumes that have system logger datasets on them

2013-06-23 Thread Nick Jones
From a logger perspective there is no clear answer, but there are a number of tools to get off the data set. Logger data sets are of the form HLQ.lsname.suffix and there are staging data sets and offload data sets. To get off of staging data sets you can change the duplex method for the log

Re: Copy a SVC Dump

2014-04-23 Thread Nick Jones
the IPCS dialog 3.2 -Nick Jones z/OS Service Aids/IPCS -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Re: IPCS BLSQMFLD NAME=

2014-05-06 Thread Nick Jones
Hi Dan, I just opened up APAR OA45131 to update BLSQMFLD. Were planning on adding a LABEL attribute to the macro. This will allow NAME to specify length and offset, while LABEL will be up to 8 characters displayed that are displayed. -Nick Jones nrjo...@us.ibm.com z/OS Service Aids

Re: 3590 tape drives

2014-07-16 Thread Nick Z
Kurt, Hope you were able to find someone to maintain your 3590-B11's and A50 controller. If you did, would you mind sharing who you made arrangements with for continued HW support? Earlier this year I upgraded my 3590-B11's and A50 controllers to 3590-E11's and A60 controllers as I was aware

Re: IXGBRWSE (LogStream Browse)

2013-02-25 Thread Nick Jones
will just mean you'll need try again later. 3) Logger issues ENF signal 48 for log steam events. Listen to the ENF signal for specific events as they might signal logstream activity. (Offload complete is a good one to look at here) -Nick

Jes3 CI queue

2014-11-12 Thread Icke, Nick
suggestions how I can remove it? 2. How can I determine why it is stuck on there, I can see nothing in the logs that give me a clue as to whats happening Tia Nick -- For IBM-MAIN subscribe / signoff / archive access

Re: Jes3 CI queue

2014-11-12 Thread Icke, Nick
at this URL http://www.listserv.uga.edu/archives/jes3-l.html Lizette -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of Icke, Nick Sent: Wednesday, November 12, 2014 7:05 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Jes3 CI queue Hi

Re: Logger Space

2015-01-17 Thread Nick Jones
data and log data sets. The section on Deleting log data give you various options depending on what application using the log streams. Using tso to delete the log data sets can cause a lot of trouble for system logger. -Nick Jones, z/OS Development

Re: IPCS error help

2015-02-11 Thread Nick Jones
This solution is assuming that Jake is on the z13 ESP and has part of OA43495 ++APARs or PTFs applied. If this is not the case then, please open a PMR and we'll investigate the problem. Nick Jones z/OS Service Aids On Wed, 11 Feb 2015 08:28:23 -0600, Nick Jones nrjo...@us.ibm.com wrote

Re: IPCS error help

2015-02-11 Thread Nick Jones
This should be corrected by making sure your miglib has the updated IOSVFMTC in it, or making sure you are on the latest ++APAR build. -- Nick Jones z/OS Service Aids -- For IBM-MAIN subscribe / signoff / archive access instructions

Contract for HLASM project

2015-07-15 Thread Nick Poulos
My group is currently looking for an individual or organization that can provide coding expertise for an HLASM coding project. The project is to convert some HLASM programs that currently use XCF for communications between LPARs to using TCP/IP for the same communications. All other processing

HLASM Coding Project

2015-07-15 Thread Nick Poulos
My group is currently looking for an individual or organization that can provide coding expertise for an HLASM coding project. The project is to convert some HLASM programs that currently use XCF for communications between LPARs to using TCP/IP for the same communications. All other

Fault Analyzer and LE ABTERMENC

2016-01-12 Thread Nick Baguley
Hi List We are seeing behaviour under fault analyser where the ABTERMENC LE runtime option is being forced to RETCODE instead of ABEND. Can anyone confirm the behaviour? TIA Nick --- This email has been checked for viruses by Avast antivirus software. https://www.avast.com

Re: CA7

2016-03-13 Thread Icke, Nick
rom: "Icke, Nick" <nick.i...@hpe.com> >Sent: Mar 12, 2016 9:52 PM >To: IBM-MAIN@LISTSERV.UA.EDU >Subject: CA7 > >Hi > >Is there a listserv specifically dealing with Ca7 > >Regards > >Nick > >

CA7

2016-03-12 Thread Icke, Nick
Hi Is there a listserv specifically dealing with Ca7 Regards Nick -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Re: FDR List

2017-01-03 Thread Icke, Nick
Whats the prob you are encountering and can you supply the exec pack, I maybe able to help Ta Nick -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of Hardee, Chuck Sent: 03 January 2017 18:56 To: IBM-MAIN@LISTSERV.UA.EDU Subject: FDR

Re: Merging two CTN STP

2017-03-17 Thread Nick G
Take a look at white paper WP102314 at http://www.ibm.com/support/techdocs This gives you various options of merging CTNs either disruptively or non-disruptively, I successfully used the non-disruptive approach last year having studied this paper very carefully.

Re: PDSE MAXGENS API

2018-05-02 Thread Nick Jones
Hi Gord, Thanks for the heads-up on FAMS. Yes, I think this is going to hurt! Nick -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Re: PDSE MAXGENS API

2018-05-02 Thread Nick Jones
to get the FAMS licence. Nick -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Re: PDSE MAXGENS API

2018-05-03 Thread Nick Jones
Many thanks, Cieri. However, this method obtains the system wide maximum as defined by MAXGENS_LIMIT in parmlib member IGDSMSxx, not the MAXGENS value defined to an individual PDSE V2 library. Nick -- For IBM-MAIN subscribe

PDSE MAXGENS API

2018-05-01 Thread Nick Jones
indicates whether that PDSE is enabled for member generations. Unfortunately, it does not get the maximum number of generations supported by the PDSE. From what I've gathered from my Google searches, I'm beginning to suspect that this information is only available via FAMS. Nick

Re: Programmatic way to create unrecoverable ABEND?

2019-04-11 Thread Nick Jones
For authorized code, you can use the CALLRTM service. This can kill the current task or any task you want. You could have a test program that abends a task in your main program. It also has options to disable retry. Nick Jones

SMFPRMFxx SYS SUBSYS and EXITs question

2019-11-26 Thread Nick Varley
in SYS, that is, in this case, it reduces the list of exits from the ten in the SYS specification to just the two that are explicitly listed? Any pointers would be welcome! Thanks, Nick. Nick Varley Director, Customer Support p +44 (0) 1823 226012 | m +44 (0) 7766 806780 nick.var...@syncsort.com

Product usage metric question: is SMF89UZT meant to be a cumulative field?

2020-01-02 Thread Nick Varley
that in the SMF record description. Is the SMF89UZT field meant to be an interval value? If so, please can you fix the z/OS code so it is. Any additional thoughts or comments are most welcome. Best wishes Nick Nick Varley Director, Customer Support p +44 (0) 1823 226012 | m +44 (0) 7766 806780

Re: EBCDIC-ASCII converter and other tools

2020-12-30 Thread Nick Jones
There is a Microsoft Windows version of the z/OS OEM batch utility, SELCOPY. SELCOPY for Microsoft Windows can be invoked as a line command in a Windows shell or from a shell script (BAT or VBS). It is capable of record based data manipulation (including ASCII<->EBCDIC) and also supports

SAS Institute IP claims against World Programming fail again

2021-01-13 Thread Nick Ciancio
it appears that the copyright and patent infringement claims that SAS brought against WPS have been dismissed or withdrawn. https://www.worldprogramming.com/press/sas_institute_ip_claims_against_world_programming_fail_again/