Re: Examples of roll your own "LIKE()" for data sets?

2018-12-04 Thread PINION, RICHARD W.
Don't suppose you have Innovation Data Processing's FDREPORT? If you did, you could set up a job to select data sets based on your requirements, and tell FDREPORT to generate JCL or ALLOCATE statements, using the DCB and space allocation information that FDREPORT gathers. -Original Message

Re: SMP/E question

2018-12-14 Thread PINION, RICHARD W.
Clone or take backups of the SMP/E environment, and apply to cloned SYSRES's and/or target libraries. -Original Message- From: IBM Mainframe Discussion List On Behalf Of R.S. Sent: Friday, December 14, 2018 9:11 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: SMP/E question [External Emai

Re: Where's the fire? | Computerworld Shark Tank

2019-01-17 Thread PINION, RICHARD W.
In 1981, I was working on a 370/168 that had 8 MB. Of course at that time, the 168 was a used machine, and not state of the art. -Original Message- From: IBM Mainframe Discussion List On Behalf Of Carmen Vitullo Sent: Thursday, January 17, 2019 10:35 AM To: IBM-MAIN@LISTSERV.UA.EDU Sub

Re: Newbie SMP/E questions

2019-01-29 Thread PINION, RICHARD W.
And on top of that, backup, ACCEPT, backup, RECEIVE, backup, APPLY -Original Message- From: IBM Mainframe Discussion List On Behalf Of Rugen, Len Sent: Tuesday, January 29, 2019 11:49 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: Newbie SMP/E questions [External Email] Some of us de

Re: Assembly JCL for tpx 5.4

2019-05-09 Thread PINION, RICHARD W.
If you really want/need them, search for a reverse assembler. I think there is one on the CBT tape. -Original Message- From: IBM Mainframe Discussion List On Behalf Of Peter Sent: Thursday, May 9, 2019 2:43 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: Assembly JCL for tpx 5.4 [External

Re: tcpip or telnet

2020-05-19 Thread PINION, RICHARD W.
This company used to have a trial copy of their software available for download. https://www.servicepilot.com/en/application-flow/mainframe/ -Original Message- From: IBM Mainframe Discussion List On Behalf Of Mike Wawiorko Sent: Tuesday, May 19, 2020 9:33 AM To: IBM-MAIN@LISTSERV.UA.EDU

System Exit

2020-06-04 Thread PINION, RICHARD W.
Does anybody have a system exit that has the ability to increase the secondary allocation for a data set, after "x" number of extents? Confidentiality notice: This e-mail message, including any attachments, may contain legally privileged and/or confidential information. If you are not the inte

Re: System Exit

2020-06-04 Thread PINION, RICHARD W.
We have IBM's TAAM, which increases the secondary allocation amount after "x" number of extents. I'm in the process of eliminating the TAAM intercepts, that SMS provides. The only thing that SMS doesn't do is the increasing of the secondary allocation. I'm turning on the DVC for all of our SMS D

Re: "Everyone wants to retire mainframes"

2020-06-09 Thread PINION, RICHARD W.
That's just the price of the current ADCD offering. To license zPDT itself is roughly $4,000/emulated CPU. -Original Message- From: IBM Mainframe Discussion List On Behalf Of John McKown Sent: Tuesday, June 9, 2020 12:24 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: "Everyone wants to re

Re: How display amount of real storage?

2020-06-22 Thread PINION, RICHARD W.
D M=STOR -Original Message- From: IBM Mainframe Discussion List On Behalf Of Charles Mills Sent: Monday, June 22, 2020 12:27 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: How display amount of real storage? [External Email. Exercise caution when clicking links or opening attachments.] Dumb

Re: How display amount of real storage?

2020-06-22 Thread PINION, RICHARD W.
] On Behalf Of Charles Mills Sent: Monday, June 22, 2020 9:36 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: How display amount of real storage? Gracias! Charles -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of PINION, RICHARD W. Sent

Re: GRSRNL Example

2020-06-29 Thread PINION, RICHARD W.
This is what we are using. /* SYSTEMS EXCLUSION RESOURCE NAME LIST - RNLDEF STATEMENTS*/ - - - - - - - - - - - - - - - - - - 1 Line(s) not Displayed RNLDEF RNL(EXCL) TYPE(SPECIFIC) QNAME(SYSDSN) RNAME(SYS1.DEVB.DAE) RNLDEF RNL(EXCL) TYPE(SPECIFIC)

SMS Data Class attribute Extended

2020-06-30 Thread PINION, RICHARD W.
We are attempting, on our QA LPAR, to use the SMS DC attributes, Data Set Name Type . . . . . : EXTENDED If Extended . . . . . . . . : PREFERRED Extended Addressability . . : YES for all of our sequential data sets. Of several hundred/thousands of dataset allocations, during the test perio

Re: SMS Data Class attribute Extended

2020-07-01 Thread PINION, RICHARD W.
ernal Email. Exercise caution when clicking links or opening attachments.] W dniu 30.06.2020 o 21:53, PINION, RICHARD W. pisze: > We are attempting, on our QA LPAR, to use the SMS DC attributes, > > Data Set Name Type . . . . . : EXTENDED >If Extended . . . . . . . . : PREFER

IFG0EX0B DCB Open Exit

2020-07-07 Thread PINION, RICHARD W.
I am using IFG0EX0B to change the secondary space quantity. From my testing, if I use IDCAMS or IBM's original IEBGENER I get the change. But, if I use DFSORT's ICEGENER or use DFSORT, I do not get the change. I used IBM's sample as my starting point. Not knowing how to test/trace this module,

Re: IFG0EX0B DCB Open Exit

2020-07-07 Thread PINION, RICHARD W.
This is what we have. ITEM JCL (ICEAM1) VALUE INV (ICEAM2) VALUE TSO (ICEAM3) VALUE TSOINV (ICEAM4) VALUE -- - - - -- OUTSE

IFG0EX0B to increase secondary allocation

2020-07-09 Thread PINION, RICHARD W.
I'd like to take this opportunity to thank Sri Kolusu, of IBM, for taking the time to help with the open exit IFG0EX0B, in regards to IEBGENER/ICEGENER and DF/SORT. He has spent the last few days researching and testing. He came up with a solution, and the exit is now working with IEBGENER/ICEGE

Re: IFG0EX0B to increase secondary allocation

2020-07-09 Thread PINION, RICHARD W.
how does it relate to JFCNWRIT? sas On Thu, Jul 9, 2020 at 1:40 PM PINION, RICHARD W. wrote: > I'd like to take this opportunity to thank Sri Kolusu, of IBM, for > taking the time to help with the open exit IFG0EX0B, in regards to > IEBGENER/ICEGENER and DF/SORT. > He has spent th

Re: OOBOL and English was Re: Still COBOL After All These Years?

2020-07-22 Thread PINION, RICHARD W.
What about cubits and stadia? -Original Message- From: IBM Mainframe Discussion List On Behalf Of Bob Bridges Sent: Wednesday, July 22, 2020 12:23 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: OOBOL and English was Re: Still COBOL After All These Years? [External Email. Exercise caution

Re: SFTP and z/OS Migration

2020-07-22 Thread PINION, RICHARD W.
As others of this list will chime in, please look at www.dovetail.com for their CoZ product line. There's the free, with no formal support, and the chargeable, with formal support. -Original Message- From: IBM Mainframe Discussion List On Behalf Of Roberto Halais Sent: Wednesday, July 2

Re: OT: OOBOL and English was Re: Still COBOL After All These Years?

2020-08-06 Thread PINION, RICHARD W.
Touche! -Original Message- From: IBM Mainframe Discussion List On Behalf Of R.S. Sent: Thursday, August 6, 2020 5:25 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: OT: OOBOL and English was Re: Still COBOL After All These Years? [External Email. Exercise caution when clicking links or open

Re: Remember the 9370?

2020-08-11 Thread PINION, RICHARD W.
I remember the IBM marketing team calling it the "VAX Killer". Our company bought the VAX instead of the 9370. -Original Message- From: IBM Mainframe Discussion List On Behalf Of Phil Smith III Sent: Tuesday, August 11, 2020 4:05 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: Remember the

Re: DASD nostalgia

2019-07-23 Thread PINION, RICHARD W.
Reading Railroad, the one that does not go past GO. -Original Message- From: IBM Mainframe Discussion List On Behalf Of Seymour J Metz Sent: Tuesday, July 23, 2019 1:47 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: DASD nostalgia [External Email] > They had three 3211 disk drives What

Re: Looking for a rexx that...

2019-07-30 Thread PINION, RICHARD W.
Do you have any third part DASD reporting software, i.e. FDREPORT? -Original Message- From: IBM Mainframe Discussion List On Behalf Of Tony Thigpen Sent: Tuesday, July 30, 2019 7:40 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Looking for a rexx that... [External Email] All, I am lookin

COBOL for z/OS V6R2M0

2019-08-02 Thread PINION, RICHARD W.
I have updated the COBOL options using IGY620.SIGYSAMP(IGYWDOPT), SMP/E usermod to update the COBOL options. IGY620.SIGYCOMP is in the system link list, and the usermod updates IGYCDOPT in that load library. After updating the module I refresh LLA with F LLA,REFRESH. I have used ISRDDN to search

Re: COBOL for z/OS V6R2M0

2019-08-02 Thread PINION, RICHARD W.
No STEPLIB/JOBLIB, and the parms being passed to the compiler are not ARCH(7), OPT(0), and NOBLOCK0. Now, there are other options being passed, LIB,TEST(HOOK). Yes, I know TEST(HOOK) is not supported with 6.2. But, that's what the programmer has in his JCL, and that's what I'm testing with. -

Re: COBOL for z/OS V6R2M0

2019-08-02 Thread PINION, RICHARD W.
e.com -Original Message- From: IBM Mainframe Discussion List On Behalf Of PINION, RICHARD W. Sent: Friday, August 2, 2019 1:36 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: (External):Re: COBOL for z/OS V6R2M0 No STEPLIB/JOBLIB, and the parms being passed to the compiler are not ARCH(7), OPT(0)

Re: COBOL for z/OS V6R2M0

2019-08-02 Thread PINION, RICHARD W.
2M0 [External Email] So does SECONDTENNESSEE move up to FIRSTTENNESSEE ?? Thank You, Chris Hoelscher| ITI . DB Services . Mainframe Database | Humana Inc.| T 502.476.2538 or 502.407.7266 -Original Message- From: IBM Mainframe Discussion List On Behalf Of PINION, RICHARD W. Sent: Frida

Re: COBOL for z/OS V6R2M0

2019-08-06 Thread PINION, RICHARD W.
What I have determined is that when I use IGYWDOPT, or at least a version that I had, my overrides are not present. If I use the non-SMPE install, I get the requested overrides. I'm in the process of trying to understand why my usermod is causing the problem. I'll probably RESTORE the usermo

Re: Submitting batch if you don't have TSO

2019-09-11 Thread PINION, RICHARD W.
Been there, done that. Fortunately, the company still had a card reader and a card punch, lat 1980's. -Original Message- From: IBM Mainframe Discussion List On Behalf Of Jesse 1 Robinson Sent: Wednesday, September 11, 2019 1:59 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: Submitting ba

Re: git with it

2019-11-05 Thread PINION, RICHARD W.
Git'er done! -Original Message- From: IBM Mainframe Discussion List On Behalf Of Lionel B Dyck Sent: Tuesday, November 5, 2019 1:20 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: git with it [External Email] On Thursday the git repository will change from private to public and you'll be

Re: DFDSS backup retore

2019-11-13 Thread PINION, RICHARD W.
Reminds me of the original STK RVA, before IBM got involved with the microcode. The box would crash, and all of the data disappeared. And there was no way to recover it. -Original Message- From: IBM Mainframe Discussion List On Behalf Of Jesse 1 Robinson Sent: Wednesday, November 13, 2

Re: Mainframe DEVOPS

2019-11-21 Thread PINION, RICHARD W.
I still have the original Tritus ISPF with the 5.25 and 3.5 diskettes. I have to run it under DOS Box. -Original Message- From: IBM Mainframe Discussion List On Behalf Of Seymour J Metz Sent: Thursday, November 21, 2019 3:51 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: Mainframe DEVOPS

Re: Mainframe DEVOPS

2019-11-21 Thread PINION, RICHARD W.
gmu.edu/~smetz3 From: IBM Mainframe Discussion List on behalf of PINION, RICHARD W. Sent: Thursday, November 21, 2019 3:57 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: Mainframe DEVOPS I still have the original Tritus ISPF with the 5.25 and 3.5 diskettes. I have to run i

Re: Looking for a utility to create a master listing of all PDS members on a system

2019-12-10 Thread PINION, RICHARD W.
Run the TSO command LISTD 'partitioned.data.set' M in a batch job executing IKJEFT01. -Original Message- From: IBM Mainframe Discussion List On Behalf Of Vernooij, Kees (ITOP NM) - KLM Sent: Tuesday, December 10, 2019 8:17 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: Looking for a util

Re: Migrated Data Set Recall Messages

2020-02-19 Thread PINION, RICHARD W.
Perhaps the environment used FDR/ABR. STC's are executed to recall data sets. FDR311 messages are displayed in SYSLOG, detailing the recall process. -Original Message- From: IBM Mainframe Discussion List On Behalf Of Elardus Engelbrecht Sent: Wednesday, February 19, 2020 2:26 PM To: IBM

Re: DF/EF andd DFP the IBM predecessor was Re: OT Boeing flight software

2020-03-01 Thread PINION, RICHARD W.
My first job as a system programmer was at a company that attempted to put DF/EF into production. It was quickly pulled out. And no, there was no test/QA environment. All they had was a 370/168, with 8MB of main storage. -Original Message- From: IBM Mainframe Discussion List On Behalf

Re: BMC and Compuware

2020-03-02 Thread PINION, RICHARD W.
WOW, Innovation Data Processing just came under Compuware's umbrella on 01/01/2020. This reminds me of UCC buying ACF2, and in short order CA bought UCC. -Original Message- From: IBM Mainframe Discussion List On Behalf Of Pommier, Rex Sent: Monday, March 2, 2020 1:02 PM To: IBM-MAIN@LIS

Re: Forcing Logonproc USSMSG10

2020-03-20 Thread PINION, RICHARD W.
Use RACF to protect the TSOPROC general resource profile. -Original Message- From: IBM Mainframe Discussion List On Behalf Of Jake Anderson Sent: Friday, March 20, 2020 10:35 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Forcing Logonproc USSMSG10 [External Email. Exercise caution when click

Re: New Jersey Pleas for COBOL Coders for Mainframes Amid Coronavirus Pandemic

2020-04-07 Thread PINION, RICHARD W.
WISP??? -Original Message- From: IBM Mainframe Discussion List On Behalf Of Seymour J Metz Sent: Tuesday, April 7, 2020 4:48 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: New Jersey Pleas for COBOL Coders for Mainframes Amid Coronavirus Pandemic [External Email. Exercise caution when cl

Re: Any shop use UNIX in a production job?

2020-04-13 Thread PINION, RICHARD W.
How about a NIC card? -Original Message- From: IBM Mainframe Discussion List On Behalf Of Bob Bridges Sent: Monday, April 13, 2020 12:07 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: Any shop use UNIX in a production job? [External Email. Exercise caution when clicking links or opening a

Re: [External] Re: Here we go again;

2020-04-23 Thread PINION, RICHARD W.
Fully agree with all of that. In addition, proper blocking will reduce CPU and DASD connect time. The worst offenders, are the ones who hard code block size in the COBOL programs. Case in point, application program specified a block size equal to record length, writing to tape. The job ran for

Re: [External] Re: Here we go again;

2020-04-23 Thread PINION, RICHARD W.
Some other things I have observed. Sequentially searching large arrays for each input record, when the input data set contained 100,000's of records. Use of DISPLAY DECIMAL or COMP-3 subscripts instead of INDEX's or at the very least using a COMP subscript. Switching to SEARCH ALL and INDEX's

Re: Developers say Google's Go is 'most sought after' programming language of 2020

2020-05-09 Thread PINION, RICHARD W.
PL/I, the language to replace all other languages. At least that's what IBM said. -Original Message- From: IBM Mainframe Discussion List On Behalf Of Tom Brennan Sent: Saturday, May 9, 2020 11:34 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: Developers say Google's Go is 'most sought af

Re: Developers say Google's Go is 'most sought after' programming language of 2020

2020-05-10 Thread PINION, RICHARD W.
What the world really needs is a HAL9000. -Original Message- From: IBM Mainframe Discussion List On Behalf Of Tom Brennan Sent: Sunday, May 10, 2020 3:25 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: Developers say Google's Go is 'most sought after' programming language of 2020 [Externa

Re: Is there a vertical split in ISPF?

2021-04-19 Thread PINION, RICHARD W.
I wonder if it would be possible for Tom Brennen to add support for a 3290 device? I wonder if ISPF SPLITV, 3290, and TN3270E are even a possibility, as the 3290/3x74 combination was a SNA thing??? I have no idea, as I can't even spell VTAM, SNA, or TN3270E. -Original Message- From: I

Diagram of MVS Control Blocks

2021-04-23 Thread PINION, RICHARD W.
Many years ago, 1982, I took my first MVS class, MVS Structure and Logic. One of the first handouts our class was given was a spaghetti diagram of MVS control blocks. Unfortunately, I threw mine away in 2016, when I thought my system programming days were over. Would anyone happen to have that

Re: Diagram of MVS Control Blocks

2021-04-23 Thread PINION, RICHARD W.
20:43 PINION, RICHARD W., wrote: > Many years ago, 1982, I took my first MVS class, MVS Structure and Logic. > One of > the first handouts our class was given was a spaghetti diagram of MVS > control blocks. > Unfortunately, I threw mine away in 2016, when I thought my system > pro

Re: Diagram of MVS Control Blocks

2021-04-25 Thread PINION, RICHARD W.
-MAIN@LISTSERV.UA.EDU Subject: Re: Diagram of MVS Control Blocks [External Email. Exercise caution when clicking links or opening attachments.] On 4/23/2021 3:43 PM, PINION, RICHARD W. wrote: > Many years ago, 1982, I took my first MVS class, MVS Structure and > Logic. One of the first ha

ibm-main@listserv.ua.edu

2021-04-30 Thread PINION, RICHARD W.
I have what is probably an elementary question. I had a program invoked SORT ABEND with a SE37-08 on a SMS managed temporary SORTOUT dataset. Here's the error stream. 11.48.03 JOB16510 IGD17273I ALLOCATION HAS FAILED FOR ALL VOLUMES SELECTED FOR DATA SET 056 056 SYS21120.T1144

ibm-main@listserv.ua.edu

2021-04-30 Thread PINION, RICHARD W.
(looking for new job) Lodz, Poland W dniu 30.04.2021 o 20:30, PINION, RICHARD W. pisze: > I have what is probably an elementary question. I had a program > invoked SORT ABEND with a SE37-08 on a SMS managed temporary SORTOUT > dataset. Here's the error stream. > > 11.48.0

Re: Program invoked SORT, SMS managed //SORTOUT DD DSN=&&TEMP [EXTERNAL]

2021-04-30 Thread PINION, RICHARD W.
scussion List On Behalf Of PINION, RICHARD W. Sent: Friday, April 30, 2021 1:30 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Program invoked SORT, SMS managed //SORTOUT DD DSN=&&TEMP [EXTERNAL] I have what is probably an elementary question. I had a program invoked SORT ABEND with a SE37-08

Re: 3270 emulator / telnet with encryption

2021-05-07 Thread PINION, RICHARD W.
M-I-C-K-E-Y M-O-U-S-E. Who remembers that song? -Original Message- From: IBM Mainframe Discussion List On Behalf Of Radoslaw Skorupka Sent: Friday, May 7, 2021 4:16 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: 3270 emulator / telnet with encryption [External Email. Exercise caution wh

Mainframe t-shirt store

2021-05-13 Thread PINION, RICHARD W.
If you haven't seen this, then check it out. www.mainframestore.com Confidentiality notice: This e-mail message, including any attachments, may contain legally privileged and/or confidential information. If you are not the intended recipient(s), or the employee or agent responsible for delivery

Re: Mainframe t-shirt store

2021-05-13 Thread PINION, RICHARD W.
ubject: Re: Mainframe t-shirt store [External Email. Exercise caution when clicking links or opening attachments.] On Thu, 13 May 2021 17:58:55 +0000, PINION, RICHARD W. wrote: >If you haven't seen this, then check it out. > >https://urldefense.com/v3/__http://www.mainframestore.

Re: Mainframe t-shirt store

2021-05-13 Thread PINION, RICHARD W.
.] ...it gets to the point to checkout/pay, and it freezes. Must not be running on a mainframe!! Mitch -Original Message- From: PINION, RICHARD W. To: IBM-MAIN@LISTSERV.UA.EDU Sent: Thu, May 13, 2021 12:58 pm Subject: Mainframe t-shirt store If you haven't seen this, then che

Re: [External] Re: JCL COND vs IF/THEN - Best catch up resources for MVS / ZOS Technologies

2021-05-20 Thread PINION, RICHARD W.
DR-DOS, now that's a name I've not heard in a long time (Obi Wan Kenobe). -Original Message- From: IBM Mainframe Discussion List On Behalf Of Pommier, Rex Sent: Thursday, May 20, 2021 10:38 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: [External] Re: JCL COND vs IF/THEN - Best catch up r

Re: [External] Re: access to 9-track reel tape drive

2021-06-08 Thread PINION, RICHARD W.
Doesn't FDR's FATS and FATR have the ability to read tapes, and skip unreadable blocks? Some data is better than no data at all. -Original Message- From: IBM Mainframe Discussion List On Behalf Of Tony Thigpen Sent: Tuesday, June 8, 2021 4:21 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re

CBT Tape

2021-06-29 Thread PINION, RICHARD W.
Does anybody remember an application on the CBT Tape, named Dirt Cheap "something or other"? Confidentiality notice: This e-mail message, including any attachments, may contain legally privileged and/or confidential information. If you are not the intended recipient(s), or the employee or agent

SDSF TMP

2021-06-30 Thread PINION, RICHARD W.
Am I only dreaming, but couldn't one execute SDSF as the TSO TMP. This might have been from the 80's or 90's timeframe. Confidentiality notice: This e-mail message, including any attachments, may contain legally privileged and/or confidential information. If you are not the intended recipient(s)

Re: SDSF TMP

2021-06-30 Thread PINION, RICHARD W.
metz3__;fg!!HnnddUIWDII9UQ!ELaFSQJID_qGZRmuTK4B-jrsSqEQ9r3OdZ7KN_YLtH3KGNiWsi_He9pAWh_xLoVhIEs$ From: IBM Mainframe Discussion List [IBM-MAIN@LISTSERV.UA.EDU] on behalf of PINION, RICHARD W. [rpin...@firsthorizon.com] Sent: Wednesday, June 30, 2021 10:07 AM To

Re: SDSF TMP

2021-06-30 Thread PINION, RICHARD W.
opening attachments.] On Wed, 30 Jun 2021 16:19:26 +, PINION, RICHARD W. wrote: >Perhaps my wording is incorrect. But, you can use PGM=SDSF in a logon proc. >I remembered that's how it was done. I tried it, and it does work. > Present tense ("does")? Do you mean y

Re: SDSF TMP

2021-06-30 Thread PINION, RICHARD W.
half Of Paul Gilmartin Sent: Wednesday, June 30, 2021 1:38 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: SDSF TMP [External Email. Exercise caution when clicking links or opening attachments.] On Wed, 30 Jun 2021 17:02:52 +, PINION, RICHARD W. wrote: >Yes I did it on a z/OS 2.4 system

Re: Report on total tape usage?

2021-07-09 Thread PINION, RICHARD W.
Do you have FDREPORT from BMC? -Original Message- From: IBM Mainframe Discussion List On Behalf Of Longnecker, Dennis Sent: Friday, July 9, 2021 11:21 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Report on total tape usage? [External Email. Exercise caution when clicking links or opening at

zEDC compression on z13 and z15

2021-07-22 Thread PINION, RICHARD W.
We migrated from a z13 to a z15 this past weekend. We are running z/OS 2.2, z/OS 2.2 on the z13, and the same z/OS 2.2 on the z15. z15 maintenance was applied to z/OS 2.2, and activated a couple of months ago. We are using the same SMS configuration on the z15 as the z13, and that includes the

Re: zEDC compression on z13 and z15

2021-07-22 Thread PINION, RICHARD W.
as the dataset DCB attributes. -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of PINION, RICHARD W. Sent: Thursday, July 22, 2021 3:55 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: zEDC compression on z13 and z15 We migrated from a z13 to a z15

Re: zEDC compression on z13 and z15

2021-07-22 Thread PINION, RICHARD W.
SERV.UA.EDU] On Behalf Of PINION, RICHARD W. Sent: Thursday, July 22, 2021 3:55 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: zEDC compression on z13 and z15 We migrated from a z13 to a z15 this past weekend. We are running z/OS 2.2, z/OS 2.2 on the z13, and the same z/OS 2.2 on the z15. z15 maintenance

Re: zEDC compression on z13 and z15

2021-07-22 Thread PINION, RICHARD W.
frame Discussion List On Behalf Of Ed Jaffe Sent: Thursday, July 22, 2021 4:47 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: zEDC compression on z13 and z15 [External Email. Exercise caution when clicking links or opening attachments.] The z15 data set is multi-volume? On 7/22/2021 1:40 PM, PINION, RICH

Re: zEDC compression on z13 and z15

2021-07-22 Thread PINION, RICHARD W.
ehalf Of PINION, RICHARD W. Sent: Thursday, July 22, 2021 4:55 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: zEDC compression on z13 and z15 [External Email. Exercise caution when clicking links or opening attachments.] OK, I've created another dataset that is single volume, same size. Ge

Printing of the ISPF Tutorial

2021-08-02 Thread PINION, RICHARD W.
Is it possible to get a hardcopy of the ISPF Tutorial? Confidentiality notice: This e-mail message, including any attachments, may contain legally privileged and/or confidential information. If you are not the intended recipient(s), or the employee or agent responsible for delivery of this messa

Re: Neat/3 [was: RE: [External] Programs that work right the first time.]

2021-08-24 Thread PINION, RICHARD W.
While I didn't take the Neat/3 class in college, it was offered. The university I attended at the time used a NCR Century 151. I "think" they were running the B3 Executive. One partition for running a batch job read in from a card reader, a SPOOL'ing partition, and the other partition was for

IEBCOPY & PARM='WORK=xxMB'

2021-09-01 Thread PINION, RICHARD W.
We are running z/OS 2.2 on z15. I am having a problem selectively unloading a very large PDS/E, over 2,000,000 tracks, and with several thousand members. The SYSIN to IEBCOPY has 174,000 SELECT statements. We are getting IEB1011E AVAILABLE STORAGE (4K) IS TOO SMALL. ADD 7779K MORE BYTES TO W

Re: IEBCOPY & PARM='WORK=xxMB'

2021-09-01 Thread PINION, RICHARD W.
rldefense.com/v3/__https://rsclweb.com__;!!HnnddUIWDII9UQ!BoyjGzxrM4lde-pxf-y3TmqAQ1Q6v2YBIANM33UknReh8LQGYtyA5jcHAH2sM0X-whU$ 'Dance like no one is watching. Encrypt like everyone is.' -Original Message- From: IBM Mainframe Discussion List On Behalf Of PINION, RICHARD W. Sen

Re: IEBCOPY & PARM='WORK=xxMB'

2021-09-01 Thread PINION, RICHARD W.
o concatenate the unload files, just do two COPY > operations (which can be in the same step, in case that's not obvious). > > REGION=32M, really? This isn't 1990. How about 1000M? > > sas > > > On Wed, Sep 1, 2021 at 10:54 AM PINION, RICHARD W. > >

Re: LISCAT with space allocations

2021-09-03 Thread PINION, RICHARD W.
If you have FDREPORT from IDP/Compuware/BMC, that's a good tool. -Original Message- From: IBM Mainframe Discussion List On Behalf Of Sri h Kolusu Sent: Friday, September 3, 2021 11:20 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: LISCAT with space allocations [External Email. Exercise ca

IBM Copy Services Manager 6.3

2021-09-08 Thread PINION, RICHARD W.
I am installing IBM CSM 6.3 on a z/OS 2.2 system. The previous install used /usr/lpp/IBM/CSM and /opt/IBM/CSM as the directories. Using the CSM 6.3 install job SYS1.SAMPLIB(IWNDDDE2), the directories have been changed to /usr/lpp/IBM/CSMDSCLI and /opt/IBM/CSMDSCLI. After running the SMP/E RECEIV

Re: IPL's POR's frequency

2021-09-14 Thread PINION, RICHARD W.
General reply, the last time the backup generator ran out of fuel! Don't laugh, it happens. -Original Message- From: IBM Mainframe Discussion List On Behalf Of McCabe, Ron Sent: Tuesday, September 14, 2021 1:03 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: IPL's POR's frequency [Extern

Re: Mainframe ransomware solution

2021-10-10 Thread PINION, RICHARD W.
The only thing I ever put on a system, similar to that, was a TSO program which produced a crude picture of the one finger salute. You could put whatever message you wanted on the hand. Silly me, I had the program executing at TSO logon. Management was not amused. -Original Message

z/OS 2.4 IPL WSC 040

2021-10-19 Thread PINION, RICHARD W.
I recently applied maintenance to our 2.4 system, and got the following attempting to IPL. Central processor (CP) 0 is in a nonrestartable stopped state due to a System Control Program (SCP) initiated reset of the I/O interface for partition BASE. The disabled wait program status word (PSW) is 0

Re: [EXTERNAL] Re: IBM ZDNT Learner's Edition - beware

2021-10-26 Thread PINION, RICHARD W.
Yeah, remember what happened when one of the original Hercules group requested the tapes for MVS/370, DOS, and VM/370. Nobody at IBM checked to determine if that was OK, and the tapes were sent. Afterwards, the hammer came down. -Original Message- From: IBM Mainframe Discussion List On

Re: Jes2 to Server

2021-10-27 Thread PINION, RICHARD W.
Take a look at McKinney Systems JRB product. It's a chargeable. But, in our opinion, it wasn't that expensive. -Original Message- From: IBM Mainframe Discussion List On Behalf Of Roberto Halais Sent: Wednesday, October 27, 2021 4:29 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Jes2 to Serv

Volume allocated to *MASTER*

2021-11-02 Thread PINION, RICHARD W.
We are running z/OS 2.2. We have a volume that is allocated to *MASTER*. Originally, the volume was allocated to XCFAS LLA, and *MASTER*. We got XCFAS and LLA to release their allocations by updating the link list. However, we cannot determine what *MASTER* is holding. I've used SDSF's JD agai

Re: Volume allocated to *MASTER*

2021-11-02 Thread PINION, RICHARD W.
rch=markjacobs@protonmail.com__;!!HnnddUIWDII9UQ!E2gIeHNsu3Tw0cV8It8sNFZ_fSXki-eFkGbvm5FjII5Kn0Qlfrwb1h2l7Mnc6HO1cT0$ ‐‐‐ Original Message ‐‐‐ On Tuesday, November 2nd, 2021 at 10:21 AM, PINION, RICHARD W. wrote: > We are running z/OS 2.2. We have a volume that is allocated > >

Re: Volume allocated to *MASTER*

2021-11-02 Thread PINION, RICHARD W.
gt; > ‐‐‐ Original Message ‐‐‐ > > > > On Tuesday, November 2nd, 2021 at 8:02 PM, Seymour J Metz > sme...@gmu.edu wrote: > > > > > Run the TIOT in the Master address and see what is allocated/ > > > > > > From: IBM Mainframe Discussion L

Re: Volume allocated to *MASTER*

2021-11-03 Thread PINION, RICHARD W.
vember 2nd, 2021 at 8:02 PM, Seymour J Metz sme...@gmu.edu >wrote: > > > Run the TIOT in the Master address and see what is allocated/ > > > > From: IBM Mainframe Discussion List IBM-MAIN@LISTSERV.UA.EDU on > > behalf of PINION, RICHARD W. rpin...@firsthorizon.com >

Re: Volume allocated to *MASTER*

2021-11-03 Thread PINION, RICHARD W.
Or RES volume naming conventions are S1RS0x, where x is a number between 1 and 3. We are IPL'ed on S1RS03, and the volume that is allocated is S1RS02. We catalog all RES volume datasets to '**'. However, there were two datasets, that were part of link list, cataloged to S1RS02. We reca

Re: Volume allocated to *MASTER*

2021-11-03 Thread PINION, RICHARD W.
We use PROGxx for APF, SYSLIB, and link list. -Original Message- From: IBM Mainframe Discussion List On Behalf Of Seymour J Metz Sent: Wednesday, November 3, 2021 2:20 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: Volume allocated to *MASTER* [External Email. Exercise caution when clicki

Re: Volume allocated to *MASTER*

2021-11-04 Thread PINION, RICHARD W.
Thank you, that's what I needed to know! -Original Message- From: IBM Mainframe Discussion List On Behalf Of Peter Relson Sent: Thursday, November 4, 2021 9:45 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: Volume allocated to *MASTER* [External Email. Exercise caution when clicking links

Re: Friday Funny

2017-03-03 Thread PINION, RICHARD W.
Y2K??? Because two K's are better than one :) -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of Dyck, Lionel B. (TRA) Sent: Friday, March 03, 2017 10:19 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Friday Funny Just noticed this PTF among

DSN=&&TEMP,DISP=(,DELETE) vs DSN=HLQ.MLQ.LLQ,DISP=(,DELETE)

2017-03-10 Thread PINION, RICHARD W.
>From an SMS ACS perspective DSN=&&TEMP,DISP=(,DELETE) creates DSNTYPE=TEMP. However, coding DSN=HLQ.MLQ.LLQ,DISP=(,DELETE) does not. Is there a way to treat them the same? FIRST TENNESSEE Confidentiality notice: This e-mail message, including any attachments, may contain legally privileged a

Re: DSN=&&TEMP,DISP=(,DELETE) vs DSN=HLQ.MLQ.LLQ,DISP=(,DELETE)

2017-03-10 Thread PINION, RICHARD W.
frame Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] > On Behalf Of PINION, RICHARD W. > Sent: 10 March, 2017 14:41 > To: IBM-MAIN@LISTSERV.UA.EDU > Subject: DSN=&&TEMP,DISP=(,DELETE) vs DSN=HLQ.MLQ.LLQ,DISP=(,DELETE) > > From an SMS ACS perspective DSN=&&TEMP,DISP=(,DE

Re: DSN=&&TEMP,DISP=(,DELETE) vs DSN=HLQ.MLQ.LLQ,DISP=(,DELETE)

2017-03-10 Thread PINION, RICHARD W.
modern, fast DASD. It is probably not worth all the effort. Elardus was right: &DSNTYPE does not catch temporary datasets, &DSTYPE does. Kees. > -Original Message- > From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] > On Behalf Of PINION, RICHARD W. &

Re: DSN=&&TEMP,DISP=(,DELETE) vs DSN=HLQ.MLQ.LLQ,DISP=(,DELETE)

2017-03-10 Thread PINION, RICHARD W.
LETE) vs DSN=HLQ.MLQ.LLQ,DISP=(,DELETE) Does the vendor offer a configuration option for this -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of PINION, RICHARD W. Sent: Friday, March 10, 2017 8:01 AM To: IBM-MAIN@LISTSERV.UA.EDU Subj

Re: 3270 emulator display/translation oddity with windows 10

2017-03-10 Thread PINION, RICHARD W.
Shameless plug for Tom Brennan's TN3270 emulator Vista, give it a shot on Win7 and Win10. -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of Bill Ashton Sent: Friday, March 10, 2017 10:19 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: 3270

Re: DSN=&&TEMP,DISP=(,DELETE) vs DSN=HLQ.MLQ.LLQ,DISP=(,DELETE)

2017-03-10 Thread PINION, RICHARD W.
-MAIN@LISTSERV.UA.EDU Subject: Re: DSN=&&TEMP,DISP=(,DELETE) vs DSN=HLQ.MLQ.LLQ,DISP=(,DELETE) On Fri, 10 Mar 2017 14:00:57 +0000, PINION, RICHARD W. wrote: >Vendor product generates HLQ.MLQ.LLA,DISP=(,DELETE) and uses dynamic >allocation. These are compile and link edit type data sets.

Re: Happy π Day!

2017-03-15 Thread PINION, RICHARD W.
No, no, it was a celebration of Three Stooges throwing pies day. -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of Pommier, Rex Sent: Wednesday, March 15, 2017 8:22 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: Happy π Day! Sorry I'm a l

PARTREL function

2017-03-16 Thread PINION, RICHARD W.
Does anybody have a program that uses the PARTREL function? FIRST TENNESSEE Confidentiality notice: This e-mail message, including any attachments, may contain legally privileged and/or confidential information. If you are not the intended recipient(s), or the employee or agent responsible for

Re: ComputerWorld Says: Cobol plays major role in U.S. government breaches

2017-03-20 Thread PINION, RICHARD W.
FWIW, I was notified that my personal information was part of the OPM data breach. Only problem is I've never worked for, nor applied for a federal job. However, back in 2007 I did work for an outsourcer who had a federal account. Perhaps that is how my personal information got there. I conta

Re: Spool file

2017-03-23 Thread PINION, RICHARD W.
I don't think HASPINDX is used anymore. -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of Edward Finnell Sent: Thursday, March 23, 2017 3:05 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: Spool file Maybe the SDSF parms point to wrong SYS

Re: Easiest way to share incore data between batch jobs

2017-03-23 Thread PINION, RICHARD W.
As someone else has already mentioned Hyperbatch. Here's a link to the manual. https://www.ibm.com/support/knowledgecenter/en/SSLTBW_2.1.0/com.ibm.zos.v2r1.idag200/hbatch.htm -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of IronSphere

  1   2   3   >