Re: [Linux-PowerEdge] iDRAC update failure

2020-11-03 Thread Patrick Boutilier
[EXTERNAL EMAIL] Have you tried resetting the iDRAC? https://www.dell.com/support/article/en-ca/sln305793/how-to-reset-the-internal-dell-remote-access-controller-idrac-on-a-poweredge-server?lang=en On 11/3/20 3:50 AM, Ben Argyle wrote: [EXTERNAL EMAIL] Hi All, I'm seeing the below in

Re: [Linux-PowerEdge] [Security Alert] Latest Dell's

2020-03-14 Thread Patrick Boutilier
[EXTERNAL EMAIL] This seems to work as a workaround. Restart dsm_om_connsvc service afterwards. mv /opt/dell/srvadmin/lib64/openmanage/jre /opt/dell/srvadmin/lib64/openmanage/jre.OLD ln -s /usr/lib/jvm/java-11-openjdk-11.0.6.10-1.el7_7.x86_64 /opt/dell/srvadmin/lib64/openmanage/jre

Re: [Linux-PowerEdge] RHEL 8.x dell-system-update RPM should include libssh2 RPM as a dependency...

2020-02-21 Thread Patrick Boutilier
ate, or they could include libssh2 in their RHEL 8 repo. Once upon a time, Patrick Boutilier said: [EXTERNAL EMAIL] Or just make a symbolic link. cd /usr/lib64 ln -s libssh.so.4 libssh2.so.1 On 2/21/20 1:05 PM, Aram Mirzadeh wrote: I downloaded libssh from github and compiled it.  I just nee

Re: [Linux-PowerEdge] RHEL 8.x dell-system-update RPM should include libssh2 RPM as a dependency...

2020-02-21 Thread Patrick Boutilier
[EXTERNAL EMAIL] Or just make a symbolic link. cd /usr/lib64 ln -s libssh.so.4 libssh2.so.1 On 2/21/20 1:05 PM, Aram Mirzadeh wrote: I downloaded libssh from github and compiled it.  I just needed the regular "Development Tools" group install. On Fri, Feb 21, 2020 at 11:47 AM

Re: [Linux-PowerEdge] DSU on RHEL8 is asking for libssh2.so.1

2020-02-04 Thread Patrick Boutilier
[EXTERNAL EMAIL] On 2/4/20 3:04 AM, Andrea Gelmini wrote: On Tue, Feb 04, 2020 at 02:46:08PM +0800, Anthony Alba wrote: In order to work, one needs to copy libssh2.so.1 from a RHEL7 installation. Yep, they (Red Hat) decided to remove libssh2 for security reason, in 8.1. In my setup

Re: [Linux-PowerEdge] Broken links on linux.dell.com

2019-10-18 Thread Patrick Boutilier
[EXTERNAL EMAIL] The "Linux" link on the SUSE page (under the Dell and SUSE heading) is the one that doesn't work https://www.dell.com/learn/us/en/05/linux-solutions On 10/18/19 9:53 AM, john.h...@dell.com wrote: Dell Customer Communication - Confidential I fixed the links yesterday by

Re: [Linux-PowerEdge] Broken links on linux.dell.com

2019-10-18 Thread Patrick Boutilier
[EXTERNAL EMAIL] "Dell and Red Hat" link works for me. Second one doesn't. On 10/18/19 5:05 AM, Stefan M. Radman wrote: [EXTERNAL EMAIL] Links are still broken. Does anyone feel responsible for these websites? Does anyone from Dell care to respond and escalate even if not responsible?

Re: [Linux-PowerEdge] hostbyte=DID_NO_CONNECT driverbyte=DRIVER

2019-02-19 Thread Patrick Boutilier
[EXTERNAL EMAIL] On 2/19/19 2:11 AM, Smith, Cathy wrote: [EXTERNAL EMAIL] Hello This message was on the console of an R720 this afternoon.  I only got it partially written before it disappeared off the screen.  Can someone explain what it means?     hostbyte=DID_NO_CONNECT

Re: [Linux-PowerEdge] SNMP required?

2018-10-16 Thread Patrick Boutilier
[EXTERNAL EMAIL] Please report any suspicious attachments, links, or requests for sensitive information. On 10/11/18 3:52 PM, A. Saber Shenouda wrote: [EXTERNAL EMAIL] Please report any suspicious attachments, links, or requests for sensitive information. Hi Everyone, Is SNMP required

Re: [Linux-PowerEdge] EXT : omconfig biossetup & passwords

2018-10-11 Thread Patrick Boutilier
[EXTERNAL EMAIL] Please report any suspicious attachments, links, or requests for sensitive information. On 10/11/18 2:21 PM, lejeczek wrote: On 30/10/2017 16:46, Gottloeb, Jeff [US] (ES) wrote:  From Dell Tech Support: Dell OpenManage Server Administrator Version 8.5 Command Line

Re: [Linux-PowerEdge] Dell EMC OpenManage 9.1.0.2

2018-08-22 Thread Patrick Boutilier
Did you restart the services after updating? srvadmin-services.sh restart On August 22, 2018 1:53:31 PM EDT, "Kienker, Fred" wrote: >Updating Dell EMC OpenManage Server Administrator to 9.1.0.2 on all our > >Rx10 hardware has essentially disabled OMSA. The web page displays but >all the

Re: [Linux-PowerEdge] RPM repo GPG key changed

2018-06-27 Thread Patrick Boutilier
On 06/27/2018 12:44 PM, John Hodrien wrote: On Wed, 27 Jun 2018, Paul Raines wrote: Definitely should have used https instead of http at least.  Other than that is it pretty common and not really different than click downloading a *.bin install file and running it with bash (I think Oracle

Re: [Linux-PowerEdge] RPM repo GPG key changed

2018-06-27 Thread Patrick Boutilier
On 06/27/2018 11:02 AM, John Hodrien wrote: On Wed, 27 Jun 2018, chandrasekha...@dell.com wrote: Hi All, We have updated the Linux repository with SHA 512 public key. Please re-run repository setup command (curl -s http://linux.dell.com/repo/hardware/dsu/bootstrap.cgi | bash) to import the

Re: [Linux-PowerEdge] RPM repo GPG key changed

2018-06-22 Thread Patrick Boutilier
On 06/22/2018 09:28 AM, Trond Hasle Amundsen wrote: writes: We used to sign using SHA1 algorithm which is deprecated and the latest packages are signed using SHA512. In-order to resolve this issue, the corresponding public key needs to be imported before yum update. Kindly run the following

Re: [Linux-PowerEdge] r815 new BIOS 3.4.0 major problem

2018-05-10 Thread Patrick Boutilier
On 05/10/2018 12:37 PM, Stephen John Smoogen wrote: On 10 May 2018 at 09:57, Patrick Boutilier <bouti...@ednet.ns.ca> wrote: On 05/10/2018 10:34 AM, lejeczek wrote: On 09/05/18 22:34, R S wrote: Is there a mechanism that prevents me to downgrade from v6.5.0 back to v6.4.0 on a R71

Re: [Linux-PowerEdge] r815 new BIOS 3.4.0 major problem

2018-05-10 Thread Patrick Boutilier
On 05/10/2018 10:34 AM, lejeczek wrote: On 09/05/18 22:34, R S wrote: Is there a mechanism that prevents me to downgrade from v6.5.0 back to v6.4.0 on a R710/T710? I downgraded the iDRAC from 2.90 to v2.80 and the 'Connection Failed' issue is still there, so I'm trying to downgrade the

Re: [Linux-PowerEdge] more downgrades: @Dell -why?

2018-02-16 Thread Patrick Boutilier
I always use -u to avoid seeing downgrades. u, --apply-upgrades-only List only upgradable updates On 02/16/2018 09:55 AM, Stefan M. Radman wrote: Kidding, are you? DSU contradicts the official Dell Support resource (not the first time).

Re: [Linux-PowerEdge] dsu woes

2018-01-18 Thread Patrick Boutilier
Well 2.7.0 is back with a warning on it. http://www.dell.com/support/article/us/en/19/sln308588/microprocessor-side-channel-vulnerabilities-cve-2017-5715-cve-2017-5753-cve-2017-5754-impact-on-dell-emc-products-dell-enterprise-servers-storage-and-networking-?lang=en On 01/18/2018 12:46 PM, R S

Re: [Linux-PowerEdge] dsu catalog version 17.11.01-MYDTM would like to downgrade the lifecycle-controller from 1.7.5.4 to 1.6.5.12

2018-01-15 Thread Patrick Boutilier
: PowerEdge R210 II Regards On 15/01/18 17:42, Patrick Boutilier wrote: What server model and iDRAC version do you have? On 01/15/2018 12:38 PM, Malte Schmidt wrote: Hello, this is still the case as of dsucatalog-18.01.00-2GT0F Regards On 04/01/18 12:58, Malte Schmidt wrote: Hello

Re: [Linux-PowerEdge] dsu catalog version 17.11.01-MYDTM would like to downgrade the lifecycle-controller from 1.7.5.4 to 1.6.5.12

2018-01-15 Thread Patrick Boutilier
What server model and iDRAC version do you have? On 01/15/2018 12:38 PM, Malte Schmidt wrote: Hello, this is still the case as of dsucatalog-18.01.00-2GT0F Regards On 04/01/18 12:58, Malte Schmidt wrote: Hello, this is still the case. Is anyone aware? Regards On 11/30/17 17:56,

Re: [Linux-PowerEdge] microcode_ctl and Spectre/Meltdown

2018-01-12 Thread Patrick Boutilier
I see 2.7.0 for 13G servers has been pulled from http://www.dell.com/support/article/us/en/19/sln308588/microprocessor-side-channel-vulnerabilities-cve-2017-5715-cve-2017-5753-cve-2017-5754-impact-on-dell-emc-products-dell-enterprise-servers-storage-and-networking-?lang=en Most likely related

Re: [Linux-PowerEdge] dsu woes

2018-01-10 Thread Patrick Boutilier
not contain any space. (8) Only Application DUP supports. On 01/10/2018 06:27 PM, Patrick Boutilier wrote: What I would do is download the BIOS update file once and then create a script to rsync it to the 1500 hosts and run the update. I presume you would have a script to run dsu on the 1500

Re: [Linux-PowerEdge] dsu woes

2018-01-10 Thread Patrick Boutilier
an option. - On 9 Jan, 2018, at 18:31, Patrick Boutilier bouti...@ednet.ns.ca wrote: | What server model do you have? Newer models have the updated firmware on | the support web site. | | | | On 01/09/2018 09:52 PM, James A. Peltier wrote: |> This is an absolutely ridiculous thing for Dell to

Re: [Linux-PowerEdge] dsu woes

2018-01-09 Thread Patrick Boutilier
What server model do you have? Newer models have the updated firmware on the support web site. On 01/09/2018 09:52 PM, James A. Peltier wrote: This is an absolutely ridiculous thing for Dell to do! Even Microsoft, Amazon, Google, and nVidia have all provided updates to mitigate the flaw

Re: [Linux-PowerEdge] Unable to move single-disk RAID-0 LD/HD between servers..

2018-01-03 Thread Patrick Boutilier
On 01/03/2018 07:48 PM, vinc...@cojot.name wrote: On Wed, 3 Jan 2018, Patrick Boutilier wrote: Did you try using the Ctrl-R interface during boot instead of MegaCLI after boot? I have always had success importing foreign configs that way. Hi Patrick, No, I did not try that. I'll do

Re: [Linux-PowerEdge] check_openmanage and OMSA 9.1.0

2017-12-26 Thread Patrick Boutilier
On 12/26/2017 09:26 AM, Stephen Berg (Contractor, Code 7320) wrote: Been updating quite a few systems to OMSA 9.1.0 on SciLinux 7.4 the last few days.  Something in there is breaking my check_openmanage services in check_mk. The last time this happened it was finally figured out that a slight

Re: [Linux-PowerEdge] Greetings. New list member. PowerEdge 6850 - Linux queries

2017-12-11 Thread Patrick Boutilier
CentOS 6.x is probably a good choice. On 12/11/2017 11:45 AM, Wes Will wrote: New member. Greetings. Tried sending before but apparently the MailMan decided I was "unclean" or something. Trying again. I was gifted with a 6850, full boat of CPUs and five 15K disks in the array. Other than

Re: [Linux-PowerEdge] DSU on CentOS Linux release 7.4.1708

2017-11-22 Thread Patrick Boutilier
In the past I have had to run dsu about 3 or 4 times in a row when getting that error then it would work. But I don't recall having to do so in the last 6 months to a year. On November 22, 2017 7:38:52 AM AST, lejeczek wrote: >it should work on Centos, I run ver 1.5.1 and

Re: [Linux-PowerEdge] rsync - no DSU_17.10.00 nor DSU_17.10.01 directories?

2017-11-01 Thread Patrick Boutilier
All looks good now. # rsync --list-only linux.dell.com::repo/hardware/dsu/ drwxr-xr-x1024 2017/11/01 09:12:16 . -rwxr-xr-x1340 2017/10/26 00:36:46 bootstrap.cgi -rwxr-xr-x6443 2017/10/26 00:36:46 bootstrap.sh -rwxr--r-- 45249 2017/10/26 01:25:46 changelog.html

Re: [Linux-PowerEdge] [E] Re: replacing a failed hard drive with PERC HBA mode

2017-08-10 Thread Patrick Boutilier
On 08/10/2017 05:49 PM, Tim Mooney wrote: In regard to: RE: [E] Re: [Linux-PowerEdge] replacing a failed hard drive...: If you're not seeing that function in the iDRAC, make sure you are running the latest version. I'm currently running firmware version 2.41.40.40 You're right, it is a

Re: [Linux-PowerEdge] Is the concept of the Lifecycle Controller just being abandoned by Dell?

2017-07-03 Thread Patrick Boutilier
We just install Linux and them use dsu to apply updates. https://linux.dell.com/repo/hardware/dsu/ On 07/03/2017 07:11 PM, Shane Forsythe wrote: This is not specific to Linux, I'm frustratingly still at the point where trying to apply updates before can goto install linux. For awhile

Re: [Linux-PowerEdge] PwrEdge T610 w/MegaRaid SAS 1078 w/ SSD's - blink "orange", but "seem to work"

2017-06-26 Thread Patrick Boutilier
On 06/26/2017 04:33 AM, Eneko Lacunza wrote: Maybe there's a config option in the controller to stop complaining about non-certified disks? On our T610 with PERC H200, OMSA shows a warning but here aren't any orange lights... To have OMSA stop complaining add to

Re: [Linux-PowerEdge] H730P in a Precision T5610?

2017-06-25 Thread Patrick Boutilier
On 06/25/2017 05:41 PM, vinc...@cojot.name wrote: Hi everyone, I was wondering if it may be possible to use a Dell PERC H730P to replace an older MegaRAID 9271-8i in a Precison T5610 workstation. I'm not too concerned about importing the existing LD's but I was wondering how would I manage

Re: [Linux-PowerEdge] iDRAC update fails via dsu

2017-06-20 Thread Patrick Boutilier
On 06/20/2017 07:01 PM, Troels Arvin wrote: Today, on two PowerEdge R720 servers, I've seen "dsu" fail to update the iDRAC. I have successfully used dsu before (and as far as I remember, this includes updating iDRACs). Updating the iDRAC by uploading a file to the iDRAC's web-interface worked,

Re: [Linux-PowerEdge] Rebuilding Array

2017-06-18 Thread Patrick Boutilier
> >Steffan Cline > >602-793-0014 > > > > > >From: <linux-poweredge-boun...@dell.com> on behalf of Patrick Boutilier ><bouti...@ednet.ns.ca> >Date: Sunday, June 18, 2017 at 11:10 AM >To: <linux-poweredge@dell.com> >Subject: Re: [Linux-

Re: [Linux-PowerEdge] Rebuilding Array

2017-06-18 Thread Patrick Boutilier
Are you trying to rebuild on the same drive without replacing it? Have you tried just reseating the drive? That should kick off a rebuild automatically. Does in RAID-5, not sure about RAID-6. On June 18, 2017 2:15:20 PM ADT, Steffan Cline wrote: >I ran into this issue a

Re: [Linux-PowerEdge] DSU replaces '-n' option with '-p'

2017-05-20 Thread Patrick Boutilier
On 05/20/2017 09:45 PM, Kilian Cavalotti wrote: HI, I'm trying to run an unattended upgrade of firmware as part of my servers deployment process and I have all the difficulties in the work to make that work. One of puzzling issues is that in the deployment environment (regular Kickstarted

Re: [Linux-PowerEdge] List responses not showing up

2017-05-18 Thread Patrick Boutilier
On 05/18/2017 01:08 PM, Lloyd Brown wrote: Is anyone else having trouble with responses to list postings not showing up? I'm not sure if it's something on my end, or something on the list end, but I've sent at least one response to the following messages, and they're not showing up in the

Re: [Linux-PowerEdge] Firmware upgrade method

2017-05-12 Thread Patrick Boutilier
You can get https://downloads.dell.com/FOLDER03547784M/1/iDRAC6_2.85_A00_FW_IMG.exe and then just unzip it to get firmimg.d6 [boutilpj@bartdl dell]$ unzip -l iDRAC6_2.85_A00_FW_IMG.exe Archive: iDRAC6_2.85_A00_FW_IMG.exe Length DateTimeName - -- -

Re: [Linux-PowerEdge] DSU return codes

2017-05-03 Thread Patrick Boutilier
My guess is that exit code 8 would mean you should reboot. I usually only reboot for BIOS and PERC updates. Does a PERC update by itself also give exit code 8? On 05/03/2017 12:00 PM, Lloyd Brown wrote: Okay. After several days of digging, I think I have dsu working well enough. But I

Re: [Linux-PowerEdge] OSMA update to 8.4.0 issue (Input/output error with /tmp/SECUPD)

2017-04-24 Thread Patrick Boutilier
What version of dsu do you have? /tmp/SECUPD problem not showing up for me with 1.4 # dsu --version Dell System Update 1.4 Copyright (C) 2014 Dell Proprietary. On 04/24/2017 12:15 PM, Quentin C. wrote: Hi Dell, Still no news of this bug reported several months ago? Do you still have

Re: [Linux-PowerEdge] omreport suddenly not giving information

2017-02-15 Thread Patrick Boutilier
Feb 15 16:17:25 albion BMAPI[34316]: ERROR SemCreate() semget() failed! No space left on device Looks like you ran out of semaphores. Couple of ways to verify: ipcs -s (this should show you the current semaphore arrays in use) These two show current settings: ipcs -sl sysctl

Re: [Linux-PowerEdge] Remote BMC command determine hardware health

2017-01-25 Thread Patrick Boutilier
If using omreport/OMSA the check_openmanage script at http://folk.uio.no/trondham/software/check_openmanage.html can be useful. On 01/25/2017 05:00 AM, David Harding wrote: Mike, Try exploring the “omreport system” options. In particular “omreport system esmlog”, whose first few lines

Re: [Linux-PowerEdge] Enumerate total disk bays

2017-01-24 Thread Patrick Boutilier
nclosure ... info=pdslotreport" command I'm guessing the 'pdslotreport" option was something added to those newer generation cards. On Tue, Jan 24, 2017 at 2:51 AM, Patrick Boutilier <bouti...@ednet.ns.ca <mailto:bouti...@ednet.ns.ca><mailto:bouti...@ednet.ns.ca <

Re: [Linux-PowerEdge] Enumerate total disk bays

2017-01-24 Thread Patrick Boutilier
On 01/24/2017 08:41 AM, Robert Jacobson wrote: Where's the documentation for which controllers support this command? I get "Operation not supported" on my R720xd with PERC H710 Mini: Same error on H700 Integrated and H730 Mini [root@sfep2 ~]# omreport storage enclosure controller=0

Re: [Linux-PowerEdge] dsu inconsistency

2017-01-23 Thread Patrick Boutilier
dell-system-update-1.3.1-17.01.00.x86_64 [-]9 PERC H730P Mini Controller 0 Firmware Current Version : 25.5.0.0018 same as : 25.5.0.0018 On 01/19/2017 10:44 AM, Ben wrote: That's great, however there _are_ updates for the PERC H730 Mini, as evidenced by the minimum required firmware for

Re: [Linux-PowerEdge] CentOS 7 dsm_om_connsvc

2017-01-20 Thread Patrick Boutilier
On 01/20/2017 12:40 PM, Support Tecnico - Crazy Network wrote: Hi everyone, i'm facing an unsusual problem. I installed few days ago a CentOS 7 Server and OMSA, it was working perfectly but since yesterday dsm_om_connsvc is not starting anymore I'm not sure if can be related, but there has

Re: [Linux-PowerEdge] RAID failure

2017-01-10 Thread Patrick Boutilier
On 01/10/2017 08:14 AM, Giulio Bottazzi wrote: Hi guys, I'm her to ask for some help and knowledgeable advice. It seems my RAID 1 has got some problem: # mpt-status -v ioc0 vol_id 0 type IM, 2 phy, 465 GB, state DEGRADED, flags ENABLED ioc0 phy 1 scsi_id 9 SEAGATE ST3500620SS MS04, 465

Re: [Linux-PowerEdge] Feedback on OMSA web interface access

2016-12-07 Thread Patrick Boutilier
On 12/06/2016 01:20 PM, omsa_feedb...@dell.com wrote: *Dell - Internal Use - Confidential * [ if you are not comfortable responding to the entire mailing list, please respond directly to *omsa_feedb...@dell.com*] Hi! Dell is conducting a survey to determine how customers are using

Re: [Linux-PowerEdge] racadm5 doesn't support iDRAC8?

2016-12-01 Thread Patrick Boutilier
arate program. -Original Message- From: linux-poweredge-boun...@dell.com [mailto:linux-poweredge- boun...@dell.com] On Behalf Of Patrick Boutilier Sent: Tuesday, November 08, 2016 2:06 PM To: linux-poweredge@dell.com Subject: Re: [Linux-PowerEdge] racadm5 doesn't support iDRAC8? On 11/08/

Re: [Linux-PowerEdge] elaborate on DSU sample kickstart files

2016-11-11 Thread Patrick Boutilier
I think those kickstart files are meant for an install that has the Dell repository installed when completed. Not to run dsu on an existing system. On November 11, 2016 7:58:31 AM AST, Robert Jacobson wrote: > > >I see there are some sample kickstart files here, supposedly

Re: [Linux-PowerEdge] racadm5 doesn't support iDRAC8?

2016-11-08 Thread Patrick Boutilier
On 11/08/2016 02:07 PM, Brian Rak wrote: I'm trying to get racadm to work with an iDRAC8 Enterprise controller. I'm getting the weird error message: ERROR: Unable to connect to RAC at specified IP address. I've checked with tcpdump, and I see racadm successfully open a TCP connection, and send

Re: [Linux-PowerEdge] accees iDrac's console on LAN from the Internet

2016-09-25 Thread Patrick Boutilier
On 09/25/2016 06:02 AM, lejeczek wrote: On 23/09/16 00:13, Patrick Boutilier wrote: On 09/22/2016 04:12 PM, lejeczek wrote: is this possible? Yes. forwarding 5900 port both for upd & tcp does not do the trick. Only need TCP. Ports 5900, and 5901. I now have both ports, also

Re: [Linux-PowerEdge] accees iDrac's console on LAN from the Internet

2016-09-22 Thread Patrick Boutilier
On 09/22/2016 04:12 PM, lejeczek wrote: is this possible? Yes. forwarding 5900 port both for upd & tcp does not do the trick. Only need TCP. Ports 5900, and 5901. would you know what NAT has to take care of in order to get me to my iDrac6? many thanks

Re: [Linux-PowerEdge] PowerEdge R210ii, Ubuntu 12.04.1 LTS, and iDRAC6/IPMI

2016-09-13 Thread Patrick Boutilier
On 09/13/2016 12:46 PM, Peter Williams wrote: Thanks! If I'm interpreting you correctly, it sounds like I *must* to have some kind of VLAN tagging set up in order for network access to work on a shared iDRAC/host Ethernet port? You don't need a vlan. We run some iDRAC 6 Expresses without vlan

Re: [Linux-PowerEdge] same after global scan

2016-08-10 Thread Patrick Boutilier
Is your RAID card (or LV) in write thru or write back mode? On 08/10/2016 12:39 AM, Daniel W Young wrote: Drives at a crawl still after global scan (background initialization) Everything working no alerts/errors just drives crawling. Takes a minute to open web browser. Running centos was

Re: [Linux-PowerEdge] [SUSPECT SPAM] proc err

2016-08-09 Thread Patrick Boutilier
On 08/09/2016 11:34 AM, Dan Young wrote: Hi Getting proc err on both processors on an old 2850 does let me reboot most times but locking couple times a day. I'm configuring a new server would like to swap coming weekend & wondering if it is possible to disable a processor in the bios.

Re: [Linux-PowerEdge] Too many levels of symbolic links

2016-08-04 Thread Patrick Boutilier
On 08/04/2016 12:33 PM, Peter Holl wrote: Hi, can someone explain why I get many (~100) messages like the following: Aug 04 15:58:34 rana systemd-readahead[658]: open(/opt/dell/invcol.5HxeZ2Wfzw/MaserApp/00-secupd-dell.rules) failed: Too many levels of symbolic links Aug 04 15:58:34 rana

Re: [Linux-PowerEdge] R730 "assuming drive cache: write through" messages on CentOS 7.2

2016-07-14 Thread Patrick Boutilier
On 07/14/2016 05:02 PM, Ryan W wrote: I'm getting this message periodically in CentOS 7.2 on a new R730 with a H730 PERC card (may not be related to the PERC) [ 183.110253] sd 12:0:0:0: [sdc] 2112 512-byte logical blocks: (1.08 MB/1.03 MiB) [ 183.111415] sd 12:0:0:0: [sdc] Write Protect is

Re: [Linux-PowerEdge] Cannot find libsmbios-2.2.27-1908.9058.el6.x86_64

2016-04-26 Thread Patrick Boutilier
Disable the old dell-omsa-repository.repo and then run: yum remove dell_ie_rac python-smbios Then yum update/upgrade should work. On 04/26/2016 09:27 AM, Manoel Pinho wrote: I have a PowerEdge with CentOS release 6.7 with the folowing repositories enabled: base dell-omsa-indep