I did it! I am truly thankful.
Yuji
2023年6月12日(月) 21:32 Jakob Erdmann :
>
> end="4"/>
>
>
> Am Mo., 12. Juni 2023 um 13:23 Uhr schrieb 渡邊勇志 :
>
>> Thank you for your response. I tried loading the additional XML into my
>> .sumocfg file, but the "begin" attribute of the Edge data
Am Mo., 12. Juni 2023 um 13:23 Uhr schrieb 渡邊勇志 :
> Thank you for your response. I tried loading the additional XML into my
> .sumocfg file, but the "begin" attribute of the Edge data became 0. The
> contents of the additional xml are written as follows:
>
> "Additional.xml"
>
>
>
>
>
Thank you for your response. I tried loading the additional XML into my
.sumocfg file, but the "begin" attribute of the Edge data became 0. The
contents of the additional xml are written as follows:
"Additional.xml"
I apologize if this is a basic question, but how can I specify a time
Hello,
the option **--edgedata-output** does not support a custom time range. To
set a custom time range you need to define the edgeData output with 'begin'
and 'end' attributes in an additional xml file and load this file in your
.sumocfg.
See
Hello,
I hope this email finds you well. I am writing to seek assistance regarding
an issue I encountered while using the Sumo simulation tool.
I successfully generated an edge-based state dump output by entering the
command "--edgedata-output " in the command line. The output was
produced