[zones-discuss] ipfilter in local zones

2007-06-05 Thread Jason Bradfield
Hi, I'm trying to get ipfilters working within a local zone on build snv_62. I'm getting the following when trying to start the ipfilter service bash-3.00# cat /var/svc/log/network-ipfilter:default.log [ Jun 5 15:33:08 Enabled. ] [ Jun 5 15:33:09 Executing start method

Re: [install-discuss] Re: [zones-discuss] updating a zone when attaching

2007-06-05 Thread James Carlson
Mike Gerdts writes: On 6/4/07, roush [EMAIL PROTECTED] wrote: Hi Jerry, This proposal mentions native zones. Please ensure that the cluster brand is treated as a native brand, as noted in PSARC 2007/304. Any details on what this is? The case doesn't seem to be available on

Re: [zones-discuss] updating a zone when attaching

2007-06-05 Thread Jerry Jelinek
Mike, Mike Gerdts wrote: This seems to imply I can do something along the lines of: lucreate -n newbe ... for zone in $allzones ; do zoneadm -z $zone halt zoneadm -z $zone detach done luupgrade -t -n newbe -s /tmp/10_Recommended ... luactivate newbe init 6 for zone in $allzones ; do

Re: [zones-discuss] updating a zone when attaching

2007-06-05 Thread Ellis, Mike
Thanks for the note and discussion jerry... I'm not a huge fan of LU (historical bagage on my part I guess) I recently started seeing its use as a some sort of means to an end. The interesting thing is that what you're proposing here (which is much more of an patch-upgrade than an

Re: [zones-discuss] updating a zone when attaching

2007-06-05 Thread Jerry Jelinek
Ellis, Mike wrote: Thanks for the note and discussion jerry... I'm not a huge fan of LU (historical bagage on my part I guess) I recently started seeing its use as a some sort of means to an end. The interesting thing is that what you're proposing here (which is much more of an patch-upgrade

[zones-discuss] Zones and Veritas Volume Manager... easy upgrades/LU usage possible ?

2007-06-05 Thread Gael
With the current thread about upgrades, I was wondering if it would be possible to upgrade our currents frames to U4 as I would like to use the memory capping capabilities of U4... the one apparent issue here is that we are using Veritas for BOTH the BE and the zones filesystems themselves. It is

Re: [zones-discuss] Zones and Veritas Volume Manager... easy upgrades/LU usage possible ?

2007-06-05 Thread Enda O'Connor ( Sun Micro Systems Ireland)
Gael wrote: With the current thread about upgrades, I was wondering if it would be possible to upgrade our currents frames to U4 as I would like to use the memory capping capabilities of U4... the one apparent issue here is that we are using Veritas for BOTH the BE and the zones filesystems

Re: [zones-discuss] Zones and Veritas Volume Manager... easy upgrades/LU usage possible ?

2007-06-05 Thread Jerry Jelinek