Hi Marshall, On Wed, 22 Nov 2000 00:24:00 -0500, Marshall Dudley <[email protected]> wrote:
>> [email protected]> wrote: >> >> Very enlightening, but would any of this apply to 'wall warts', which >> never have a 3rd prong? --Russ > >Absolutely, that is what is so beautiful about them. They use a transformer >to monitor the current in each half of the circuit, and buck the two >currents. The difference current is pulled off with a 3rd winding, and goes >to an electronic circuit that triggers when the imbalance is more than some >amount, 2 to 5 mA or so. Are you sure? I'm going to have to test some. The GFI's 20 years ago didn't seem to do that (that's the last time I tested them). >See http://www.misterfixit.com/gfi.htm for more information: Two coils, huh? I thought it was 2 resistors in a bridge. :) However, I don't think a GFI would solve the problem described for wall-warts. If, somehow (and don't ask me how), a wall-wart put out 120 v on the hot terminal and 0 volts on the other, the GFI should measure the same current through both sides of it's sensor -- unless you happened to touch a grounded object (or are standing in a puddle). -- Dean -- from (almost) Duh Moyn (CDP, KB0ZDF) -- The silver-list is a moderated forum for discussion of colloidal silver. To join or quit silver-list or silver-digest send an e-mail message to: [email protected] -or- [email protected] with the word subscribe or unsubscribe in the SUBJECT line. To post, address your message to: [email protected] Silver-list archive: http://escribe.com/health/thesilverlist/index.html List maintainer: Mike Devour <[email protected]>