On 5/16/2010 10:34 PM, Todd Hodgen wrote:
Under Device, Gateway, your gateway, under ITSP options, click the checkbox
for "register on initialization" box. It is no longer defaulted, and it
should be.
"Register on initialization" IS checked.
On the right side of the screen it says:
"(Default: checked)"
The voip.ms portal has the following option:
**
To use SIP by IP authentication instead of dynamic register, use the
sub account section.
From the sub accounts, you can create additional SIP and IAX accounts.
Should I try this method to authenticate by IP address instead of
user/password?
On my sipXecs 4.2 system I did the following:
Internal SBC Route
sipxbridge-1 10.8.158.121
SIP settings all default
Gateway
SBC Route: sipXbridge-1
Address: toronto.voip.ms
(email from voip.ms said sip.ca2.voip.ms was deprecated
replaced by toronto.voip.ms)
Dial Plan: Long Distance
ITSP Account
User Name: xxxxxx
Password: xxxxxx
All other settings default.
--
Norman Branitsky +1 416.798.7948
Cherniak Software Development Corporation Fax: +1 416.798.0948
509-2001 Sheppard Avenue East [email protected]
Toronto, ON M2J 4Z8 sip:[email protected]
Canada http://www.CherniakSoftware.com
_______________________________________________
sipx-users mailing list [email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-users
Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users
sipXecs IP PBX -- http://www.sipfoundry.org/