Wrong... read below...

On Mon, May 17, 2010 at 10:22 AM, Norman Branitsky <
[email protected]> wrote:

> On 10-05-17 6:13 AM, Tony Graziano wrote:
>
>> Port 5080 must be symettrically nat'ed to register.
>>
>>
> Just to confirm "Symmetric NAT" -
> sipXecs sends a request to voip.ms from 10.8.158.121 port 5080;
> firewall adds an entry to its NAT table and substitutes the external IP
> address
> 216.8.158.237 for 10.8.158.121 in the packets forwarded to voip.ms;
> voip.ms responds to 216.8.158.237 port 5080;
> firewall finds this entry in the NAT table and substitutes the internal IP
> address
> 10.8.158.121 for 216.8.158.237 in the packets returned to sipXecs.
> sipXecs sends some form of "keep alive" packets to voip.ms to maintain the
> NAT table entry.
> Correct?
>
> SIP trunking Public Port defaults to 5060 - should this be 5080?
>
> Remote users is port 5060, trunking is 5080.

Don't change the settings for 5060 in sipxbridge or the voip.ms template.
You are still sending them call on 5060, they are simply sending you the
call setup on 5080.

> Stricltly NAT - no "port forwarding" defined.
> My firewall does not do "port forwarding" -
> if an internal machine needs incoming access from the internet,
> I define a single address route like 216.8.158.225/32 to 10.8.158.225
> and add rules to the firewall defining what ports and protocols are allowed
> over this route. To make this work, the target machine must have an
> eth0 address of 10.8.158.225/24 and an IP alias of 216.8.158.225/32.
> FreeBSD allows me to create IP aliases.
> Linux (CentOS 5.2) requires me to create the alias thus:
> eth0:0 216.8.158.225 netmask 255.255.255.255 ...
> I was concerned that sipXecs would see this alias as a second IP address
> and become confused because all the documentation says:
> "thou shalt not use multiple IP addresses!".
>
> You simply need to ensure both ports (5060 for remote users if you have
them, and 5080 for trunking) are natted properly.

>
> --
> Norman Branitsky                                 +1 416.798.7948
> Cherniak Software Development Corporation   Fax: +1 416.798.0948
> 509-2001 Sheppard Avenue East        [email protected]
> Toronto, ON M2J 4Z8              sip:[email protected]
> Canada                           http://www.CherniakSoftware.com
>
>


-- 
======================
Tony Graziano, Manager
Telephone: 434.984.8430
sip: [email protected]
Fax: 434.984.8431

Email: [email protected]

LAN/Telephony/Security and Control Systems Helpdesk:
Telephone: 434.984.8426
sip: [email protected]
Fax: 434.984.8427

Helpdesk Contract Customers:
http://www.myitdepartment.net/gethelp/

Why do mathematicians always confuse Halloween and Christmas?
Because 31 Oct = 25 Dec.
_______________________________________________
sipx-users mailing list [email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-users
Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users
sipXecs IP PBX -- http://www.sipfoundry.org/

Reply via email to