Sounds like the array is using a subset of the VPD info mpxio uses to figure out which LUN is which. How are you setting mpxio up to "see" the array?
Andrew Hurt wrote: > cfgadm has been aware of every LUN (28 of them) all along. That's never been > the issue. Even when I get into the HBA's FastUtil! BIOS at boot time I can > see all 28 LUNs out there. > > I should note that when I disable mpxio in fp.conf, reconfigure/reboot, > 'format' shows 112 drives (28 drives x 4 FC links). Obviously, this is not a > desired result, but it does serve to illustrate that the HBAs can see all 28 > drives out there. > > It is only when multipathing is enabled that the problem manifests itself: > 'format' shows 4 drives (LUN 0 of each Xserve RAID controller) instead of the > desired result of 28 drives (LUNs 0-6 of each Xserve RAID controller). > > I've been a lurker on alienraid for a long time as well. I found nothing > of particular use to my specific scenario. A few tidbits about the > Apple-branded LSI HBAs not supporting mpxio, but nothing helpful for me. I'm > using the official Sun-sourced Qlogis HBAs (QLE2462)s. > > Thanks for the feedback, though. Anyone else? > > > This message posted from opensolaris.org > _______________________________________________ > storage-discuss mailing list > [email protected] > http://mail.opensolaris.org/mailman/listinfo/storage-discuss > > _______________________________________________ storage-discuss mailing list [email protected] http://mail.opensolaris.org/mailman/listinfo/storage-discuss