On Sun, Oct 16, 2016 at 12:26 AM, J Portman <[email protected]> wrote: > Yup, but the EPC vlans are hard set to 1500 at the current time and no way > to change them. Beating my head against this wall right now. >
Using the resources in this thread, I've tracked down a couple points of interest. ENBs running [4013, 4539, or 4573] return a full packet (ICMP+headers) of MTU 1900. (Payload 1900-28=1872) This is on either bearer or management VLANs. EPC running 729, however, returns only 1496 (1468+headers). This is on several PDNs, management, and bearer. In all cases (Mikrotik routers, Netonix switches in some places) MTU size is set to 1900 or higher. On the EPC, netstat does not appear to show interface info (no -i flag), so I can't tell what the MTU is purported to be. Has anyone had success verifying and/or changing the EPC's MTU(s)? -- Jeremy Austin (907) 895-2311 (907) 803-5422 [email protected] Heritage NetWorks Whitestone Power & Communications Vertical Broadband, LLC Schedule a meeting: http://doodle.com/jermudgeon
_______________________________________________ Telrad mailing list [email protected] http://lists.wispa.org/mailman/listinfo/telrad