What firmware version are you running there? I think I already fixed that.
Scott wfjordan444 wrote: > > > Hi, Scott. Here's the command, sent to the T2-301 at the remote tower site: > AE4S ³<A22>cmd:info > AE4S-2 ³<Aac>TEMP:-175F VOLT:13.39 RX:17762 FCS:29733 DIGI:3603 CFG:1 > PWD:0 RSSIAE4S > > --- In [email protected] <mailto:tracker2%40yahoogroups.com>, > Scott Miller <sc...@...> wrote: > > > > Are you seeing this at the command prompt, or only on remote commands? > > If you use the INFO command locally, do you get a "S*" flag at the end? > > > > Scott > > > > wfjordan444 wrote: > > > > > > > > > I have certainly learned a great deal from your responses, for > which I'm > > > most grateful. > > > > > > Do any of you have thoughts about the RSSI truncation? I've been > sending > > > a RESET before the INFO as a workaround. > > > > > > Bill > > > > > > --- In [email protected] <mailto:tracker2%40yahoogroups.com> > <mailto:tracker2%40yahoogroups.com>, > > > Scott Miller <scott@> wrote: > > > > > > > > If you don't have PWAUTH enabled, * lets in everyone. AUTHLIST is > > > > checked first, then PWAUTH if enabled. > > > > > > > > Scott > > > > > > > > Keith VE7GDH wrote: > > > > > > > > > > > > > > > Scott N1VG wrote... > > > > > > > > > > > Or you can put a * in the first AUTHLIST entry and use only the > > > PWAUTH > > > > > > mechanism. > > > > > > > > > > Guess I could try it myself, but with * in AUTHLIST, can any > callsign > > > > > sends commands to a T2, or only if the requirements of SECRET / > PWAUTH > > > > > are met? > > > > > > > > > > 73 es cul - Keith VE7GDH > > > > > -- > > > > > "I may be lost, but I know exactly where I am!" > > > > > > > > > > > > > > > > > > > > > > > >