NoAlox is a benefit but not a cure all for aluminum wires connected to receptacles and switches not specifically made for aluminum wire. The problem is that at any where near rated load the aluminum wire will expand. When constrained by a brass screw the aluminum can only extrude sideways out from under the screw. Then when the aluminum cools (it expands and contracts more than brass) there's an instant loose connection. That makes the joint heat more rapidly the next time. At a MINIMUM all outlets and switches in aluminum wiring must be replaced with outlets and switches rated for aluminum wire. Duplex receptacles cost about $3 each at Lowe's or Home Depot. NoAlox should be used on the replacement receptacles and switches. Gerald J. To unsubscribe or to change to a daily Digest, please go to http://www.airstream.net/vaclist/listoffice.html If replying back to this message, please delete all the unnecessary original text from your reply.
[VAC] Re: Water & electric
Dr. Gerald N. Johnson, electrical engineer Tue, 06 Mar 2001 08:34:47 -0800
- [VAC] Re: Water & electric Agrijeep
- [VAC] Re: Water & elec... Dr. Gerald N. Johnson, electrical engineer
- [VAC] Re: Water & elec... Robert C Townsend
- [VAC] Re: Water & elec... Jim Greene
- [VAC] Re: Water & elec... Jim Dunmyer
- [VAC] Re: Water & elec... Dr. Gerald N. Johnson, electrical engineer
- [VAC] Re: Water & elec... Dr. Gerald N. Johnson, electrical engineer
- [VAC] Re: Water & elec... Wayne A Moore
- [VAC] Re: Water & elec... Wayne A Moore
- [VAC] Re: Water & elec... Mr. Joy H. Hansen
- [VAC] Re: Water & elec... Dr. Gerald N. Johnson, electrical engineer
- [VAC] Re: Water & elec... Dr. Gerald N. Johnson, electrical engineer
- [VAC] Re: Water & elec... Jim Dunmyer
- [VAC] Re: Water & elec... Mr. Joy H. Hansen
- [VAC] Re: Water & elec... Dr. Gerald N. Johnson, electrical engineer
- [VAC] Re: Water & elec... Jim Dunmyer
- [VAC] Re: Water & elec... Jim Clark