Bob,

No the bath is not a condensate.  It can be disordered - quoting the paper:

 "With help of the spin-echo phenomenon it is possible to extract work
  from a disordered ensemble of spins having random frequencies. This
  ensemble can even be strongly disordered in the sense that the
  relaxation time T2* induced by the disorder is much smaller than both
  the T2-time and the response time of the bath."

If I can find some additional references on this, I will post them.
Very surprising results.

-- Lou Pagnucco

> Lou--
>
> Bob Cook here-
>
> Do you know if the Bose thermal bath that the second referenced report
> talks
> about is the same thing as a Bose -Einstein Condensate (BEC)?
>
> Bob
> ----- Original Message -----
> From: <[email protected]>
> To: <[email protected]>
> Sent: Sunday, February 09, 2014 11:16 AM
> Subject: RE: [Vo]:Spin this ...
>
>
>> Perhaps there are some counter-intuitive ways to extract heat energy
>> from the environment using spin reservoirs.  If real, probably just an
>> apparent (but useful) exploitation of a 2nd Law loophole.
>>
>> A couple of references:
>>
>> "Single-reservoir heat engine: Controlling the spin"
>> http://fqmt.fzu.cz/13/pdfabstracts/605_1f.pdf
>>
>> "Work extraction in the spin-boson model"
>> http://arxiv.org/abs/quant-ph/0411018
>>
>> -- Lou Pagnucco
>>
>> Jones Beene wrote:
>>> Attn: spin doctors
>>>
>>> Hope this is not belaboring the point about the intrinsic magnetic
>>> connection that exists, and may in fact be causative - to a finding of
>>> gain
>>> in LENR systems. Consider one further major point in the context of
>>> Steven
>>> Jones' finding of an RF signature.
>>>
>>> Consider the field of NMR but in the context of RF. The importance of
>>> an
>>> RF
>>> signal in NMR is not RF alone, but than an intense single resonant
>>> frequency
>>> is seen, which is determined by the external field alignment of the
>>> nucleus.
>>> The stronger the field the more robust the signal
>>>
>>> OK backtracking to Steven Jones, and his slide showing an RF signal -
>>> we
>>> must realize that because of the strong self-field of hydrogen
>>> (deuterium)
>>> even the very weak magnetic field of earth is enough to see some signal
>>> but
>>> only with hydrogen or deuterium.
>>>
>>> See where this is heading?
>>>
>>> Connect the dots and we are looking at more than NMR, and more than
>>> LENR -
>>> it is NMR in the context of LENR, as perhaps the driving force.
>>>
>>> _____________________________________________
>>>
>>>
>>> For the various Spin Doctors on Vortex -  2.3. Magnetic
>>> Stimulation
>>>
>>> After the cathode had been charged with deuterium for 48
>>> hours at a current of 80 mA, the cell was placed in the field of a
>>> permanent
>>> magnet of 200 Gauss strength. The cell electrolyte temperature rose to
>>> 5
>>> °
>>> C
>>> (Fig.10.) after 230 seconds, After 576 seconds, the magnet was replaced
>>> by
>>> two, one inch Neodymium magnets with a 800 Gauss field placed as
>>> described
>>> earlier. The temperature immediately started increasing and reached
>>> 13.5
>>> °
>>> C
>>> in about 15 minutes and remained constant. The temperature returned to
>>> 3.5
>>> °
>>> C when the magnet was removed.
>>>
>>
>>
>>
>
>
>


Reply via email to