Bob, No the bath is not a condensate. It can be disordered - quoting the paper:
"With help of the spin-echo phenomenon it is possible to extract work from a disordered ensemble of spins having random frequencies. This ensemble can even be strongly disordered in the sense that the relaxation time T2* induced by the disorder is much smaller than both the T2-time and the response time of the bath." If I can find some additional references on this, I will post them. Very surprising results. -- Lou Pagnucco > Lou-- > > Bob Cook here- > > Do you know if the Bose thermal bath that the second referenced report > talks > about is the same thing as a Bose -Einstein Condensate (BEC)? > > Bob > ----- Original Message ----- > From: <[email protected]> > To: <[email protected]> > Sent: Sunday, February 09, 2014 11:16 AM > Subject: RE: [Vo]:Spin this ... > > >> Perhaps there are some counter-intuitive ways to extract heat energy >> from the environment using spin reservoirs. If real, probably just an >> apparent (but useful) exploitation of a 2nd Law loophole. >> >> A couple of references: >> >> "Single-reservoir heat engine: Controlling the spin" >> http://fqmt.fzu.cz/13/pdfabstracts/605_1f.pdf >> >> "Work extraction in the spin-boson model" >> http://arxiv.org/abs/quant-ph/0411018 >> >> -- Lou Pagnucco >> >> Jones Beene wrote: >>> Attn: spin doctors >>> >>> Hope this is not belaboring the point about the intrinsic magnetic >>> connection that exists, and may in fact be causative - to a finding of >>> gain >>> in LENR systems. Consider one further major point in the context of >>> Steven >>> Jones' finding of an RF signature. >>> >>> Consider the field of NMR but in the context of RF. The importance of >>> an >>> RF >>> signal in NMR is not RF alone, but than an intense single resonant >>> frequency >>> is seen, which is determined by the external field alignment of the >>> nucleus. >>> The stronger the field the more robust the signal >>> >>> OK backtracking to Steven Jones, and his slide showing an RF signal - >>> we >>> must realize that because of the strong self-field of hydrogen >>> (deuterium) >>> even the very weak magnetic field of earth is enough to see some signal >>> but >>> only with hydrogen or deuterium. >>> >>> See where this is heading? >>> >>> Connect the dots and we are looking at more than NMR, and more than >>> LENR - >>> it is NMR in the context of LENR, as perhaps the driving force. >>> >>> _____________________________________________ >>> >>> >>> For the various Spin Doctors on Vortex - 2.3. Magnetic >>> Stimulation >>> >>> After the cathode had been charged with deuterium for 48 >>> hours at a current of 80 mA, the cell was placed in the field of a >>> permanent >>> magnet of 200 Gauss strength. The cell electrolyte temperature rose to >>> 5 >>> ° >>> C >>> (Fig.10.) after 230 seconds, After 576 seconds, the magnet was replaced >>> by >>> two, one inch Neodymium magnets with a 800 Gauss field placed as >>> described >>> earlier. The temperature immediately started increasing and reached >>> 13.5 >>> ° >>> C >>> in about 15 minutes and remained constant. The temperature returned to >>> 3.5 >>> ° >>> C when the magnet was removed. >>> >> >> >> > > >