I'm running Windows 10, WSJT-X 1.5 r4693, and the hamlib integration fork
rev 3477.  I have been keeping up with WSJT-X 1.5 changes pretty much daily
with few exceptions.
Also potentially relevant I'm using a signalink USB and an OMNI VII with my
own omnivii.c driver.

I always leave my system running overnight.

For the first time ever came in this morning and there were no decodes on
40M for about the last 6 hours and the waterfall was not progressing.

Everything on WSJT-X was operational.  Turning Monitor on/off had no effect.
Went into File/Radio/Settings and did a "Test CAT" and it came back
green...still no decoding though...so serial I/O to the Omni appears OK and
not the problem.
What fixed it was going into File/Settings/Radio and changing the Input over
to my sound card and decoding started again.  Then back again to the
Signalink and all is well.

I've never had this happened before.  I just started using the hamlib
integration fork but it doesn't appear to me that it was the problem or my
Omni driver since the Signalink USB shouldn't be related to that.

I've not tried debugging a running instance yet.  I assume it's just running
gdb to attach to the process and then setting a break point on the decoding
invocation to then trace why it's not progressing?

Mike W9MDB







------------------------------------------------------------------------------
Download BIRT iHub F-Type - The Free Enterprise-Grade BIRT Server
from Actuate! Instantly Supercharge Your Business Reports and Dashboards
with Interactivity, Sharing, Native Excel Exports, App Integration & more
Get technology previously reserved for billion-dollar corporations, FREE
http://pubads.g.doubleclick.net/gampad/clk?id=157005751&iu=/4140/ostg.clktrk
_______________________________________________
wsjt-devel mailing list
wsjt-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/wsjt-devel

Reply via email to