Hi Tom,
thanks for that. So it seems that something is blocking COM
communications between WSJT-X and Omni-Rig that is resolved by running
WSJT-X with elevated rights. The Windows security model, in general,
blocks IPC between processes running at different security levels. If
that is the issue then perhaps somehow Omni-Rig can only be started
using elevated rights. Is it possible that the OmniRig.exe file has a
security restriction applied? On my system if I check the effective
rights for my non-administrator user to the omnirig.exe file I see this:
which includes read and execute. Is it the same on your system?
I am not sure why you are asking about how WSJT-X accesses serial ports,
when using Omni-Rig it doesn't access serial ports. To access COM
services we use a Qt library Active that allows us to access COM
services without the low level details of handling COM in C. We also use
a Qt tool called dumpcpp which generates Active Qt COM wrappers by
querying the COM server via its GUID to enumerate its COM API.
https://doc.qt.io/qt-5/activeqt-index.html
73
Bill
G4WJS.
On 18/07/2021 18:55, Tom via wsjt-devel wrote:
Hi
Ok. I did this. When you run WSJT without being admin, no log is made
at all. You get Failed to start Omni Rig COM server in WSJT
If you run it as admin, then a log appears.
Here are the first few lines…
13:45:51.670 Omni-Rig started: Version 1.19
13:45:51.675 Loading commands from "ZS-1.ini"
13:45:51.691 Loading commands from "TS-930.ini"
13:45:51.707 Loading commands from "TS-870.ini"
If you run Log4OM for example NOT as admin, a log is created as above.
Since this happens with an older version of WSJT and the latest
versions (production) most likely a library somewhere has been
changed. Perhaps by Windows update.
I remember a couple of years ago, that I had a sound device stuck in
WSJT even though the device wasn’t installed. . We worked on it a lot
to no resolution. A subsequent Windows update fixed it.
What libraries are you using for serial port access? Or the com server?
73 Tom
*From:*Bill Somerville via wsjt-devel <wsjt-devel@lists.sourceforge.net>
*Sent:* Sunday, July 18, 2021 1:32 PM
*To:* wsjt-devel@lists.sourceforge.net
*Cc:* Bill Somerville <g4...@classdesign.com>
*Subject:* Re: [wsjt-devel] WSJT-X and Omni-Rig: Failed to start Omni
Rig COM server
Tom,
I did have a minor typo in the first path I wrote below, other than
that it most certainly is where the Omni-Rig configuration file is found:
C:\Users\bill\build>dir "%AppData%\Afreet\Products\OmniRig\"
Volume in drive C is Windows8_OS
Volume Serial Number is 56CD-82B3
Directory of C:\Users\bill\AppData\Roaming\Afreet\Products\OmniRig
20/04/2017 15:16 <DIR> .
20/04/2017 15:16 <DIR> ..
18/07/2021 08:38 762 OmniRig.ini
14/08/2016 00:16 282 OmniRig.ini~
18/07/2021 08:36 18,617 OmniRig.log
3 File(s) 19,661 bytes
2 Dir(s) 62,254,145,536 bytes free
Note Products, not Produxts as I mis-typed.
At this point I think that running anything here with elevated rights
causing different behaviour is coincidental.
I also think the "Failed to start Omni-Rig COM server" is somewhat
bogus too as you have proved that if you stat the server manually
WSJT-X still fails to hook up with it. I am hoping the Omni-Rig debug
log has some entry that tells me what is actually happening.
73
Bill
G4WJS.
On 18/07/2021 17:19, Tom via wsjt-devel wrote:
Hi
There is no such path. I am using omni-rig 1.19 just downloaded
from the web at dxatlas.
The use of administrator mode only works for the 64 bit WSJT. The
32 bit fails with both user and administrator mode. Always failed
to start the omnirig com server.
Tom
*From:*Bill Somerville via wsjt-devel
<wsjt-devel@lists.sourceforge.net>
<mailto:wsjt-devel@lists.sourceforge.net>
*Sent:* Sunday, July 18, 2021 3:39 AM
*To:* wsjt-devel@lists.sourceforge.net
<mailto:wsjt-devel@lists.sourceforge.net>
*Cc:* Bill Somerville <g4...@classdesign.com>
<mailto:g4...@classdesign.com>
*Subject:* Re: [wsjt-devel] WSJT-X and Omni-Rig: Failed to start
Omni Rig COM server
Hi Tom,
thanks for the clarification. You didn't confirm which version of
Omni-Rig you are using.
It would be interesting to see the Omni-Rig debug log for a test
where WSJT-X claims it is unable to start the Omni-Rig COM server.
To enable Omni-Rig debug logging put the following into the main
Omni-Rig settings file
"%AppData%\Afreet\Produxts\OmniRig\OmniRig.ini" at the top:
[Debug]
Log=1
The log file is called OmniRig.log and appears in the same
"%AppData%\Afreet\Products\OmniRig\" directory.
73
Bill
G4WJS.
On 17/07/2021 00:42, tom via wsjt-devel wrote:
Hi
No, I don't think I said this right.
If you open omnirig while you monitor the serial port, the
serial port opens, then there's a little activity and then the
port closed. Omnirig remains open.
Starting wsjt with omnirig open or closed produces the same
result. Failed to start com server unless you run it as admin.
Tom
Sent from my Galaxy
-------- Original message --------
From: Bill Somerville via wsjt-devel
<wsjt-devel@lists.sourceforge.net>
<mailto:wsjt-devel@lists.sourceforge.net>
Date: 2021-07-16 5:56 p.m. (GMT-05:00)
To: wsjt-devel@lists.sourceforge.net
<mailto:wsjt-devel@lists.sourceforge.net>
Cc: Bill Somerville <g4...@classdesign.com>
<mailto:g4...@classdesign.com>
Subject: Re: [wsjt-devel] WSJT-X and Omni-Rig: Failed to start
Omni Rig COM server
Hi Tom,
that's not how Omni-Rig behaves for me, if I start it manually
the setup dialog stays open until it is cancelled or closed
with the OK button. Starting WSJT-X to communicate with it
doesn't change that. What version of Omni-Rig are you using?
73
Bill
G4WJS.
On 16/07/2021 22:49, Tom via wsjt-devel wrote:
Hi
Omni-rig connects just fine to the radio. When you open
it there is some initial comport activity then it closes.
All this is normal.
It is completely reproducible on my system. There is no
issue with any other application that uses Omni-rig.
On the groups.io list, there are people that have reported
this in the past.
73 Tom
*From:*Bill Somerville via wsjt-devel
<wsjt-devel@lists.sourceforge.net>
<mailto:wsjt-devel@lists.sourceforge.net>
*Sent:* Friday, July 16, 2021 4:03 PM
*To:* wsjt-devel@lists.sourceforge.net
<mailto:wsjt-devel@lists.sourceforge.net>
*Cc:* Bill Somerville <g4...@classdesign.com>
<mailto:g4...@classdesign.com>
*Subject:* Re: [wsjt-devel] WSJT-X and Omni-Rig: Failed to
start Omni Rig COM server
Hi Tom,
OK, I've not see that behaviour. Are you able to reproduce
it? If yes, then does starting Omni-Rig manually before
starting WSJT-X work correctly?
73
Bill
G4WJS.
On 16/07/2021 20:59, tom via wsjt-devel wrote:
Hi
Actually no. When you start wsjt it immediately gives
an error saying failed to start omnirig com server. If
you monitor the serial port traffic, nothing happens
at all. No serial communications at all.
If you start wsjt as administrator it works without an
issue. This doesn't happen with any other software
that uses omnirig. It's strange because this always
worked in the past.
73 Tom va2fsq
Sent from my Galaxy
-------- Original message --------
From: Bill Somerville via wsjt-devel
<wsjt-devel@lists.sourceforge.net>
<mailto:wsjt-devel@lists.sourceforge.net>
Date: 2021-07-16 3:36 p.m. (GMT-05:00)
To: wsjt-devel@lists.sourceforge.net
<mailto:wsjt-devel@lists.sourceforge.net>
Cc: Bill Somerville <g4...@classdesign.com>
<mailto:g4...@classdesign.com>
Subject: Re: [wsjt-devel] WSJT-X and Omni-Rig: Failed
to start Omni Rig COM server
On 16/07/2021 20:10, Tom via wsjt-devel wrote:
> I am the author of Win4IcomSuite and have started
getting reports of WSJT
> failing to start the Omni-rig COM server. This does
not happen on all
> computers. In addition, it starts happening when no
changes have been made
> to Omni-rig and WSJT. Installing the latest
versions does not correct the
> issue.
> To reproduce:
> Reboot your computer and make sure there are no
other applications using
> omni-rig.
> Use Omni-rig definition for your Icom radio;. Start
WSJT. You receive the
> above error.
> Run WSJT as Administrator and it works.
>
> All other applications using Omni-rig work without
putting them in
> administrator mode. No other related software is
running. This is with a
> direct connection to the radio.
>
> Details, version 2.4.0 (happens on previous version
as well).
> Windows 10, version 19041.1083
> 73 Tom va2fsq
Tom,
I am looking into this issue, you don't need to keep
repeating your query.
So far I see one problem with startup when there is a
fault condition
like the rig not being accessible, or if WSJT-X is
closed down before it
has completed all the retries it attempts before
reporting an error
(that takes up to 10 seconds). Is that consistent with
what you are
reporting? If so, then if WSJT-X is left for 20
seconds or so to do its
own thing does an error get reported?
73
Bill
G4WJS.
_______________________________________________