Last sentence may be a bit ambiguous. I mean the node is sending proper readings despite the CAN error.
May I me having problems with the BEI because of this error? from the thread with Stephane I understand that this BEI cannot be switched off? Regards, Roland On 3/6/07, roland Tollenaar <[EMAIL PROTECTED]> wrote:
> > The mode is empty. > > Always. I don;t set the mode in the application and on running > > rtcanrecv I don't specify loopback. > > > > What else can I do to make certain there is no listen_only mode on? > > You could explicitely call SIOCSCANCTRLMODE with 0. Am now doing so. No difference. > > > > > > > this is not a kernel setting. loopback and listenonly capability is > > > > set in the kernel but I am not using it at the moment. But it is > > > > usefull for testing and it should not be a problem if not turned on? > > > > > > So far you are right. > > > > > > See above. I'm not convinced. > > > > If its any consolation I have not seen that message for a while. But > > of course I have debug messages turned off in the kernel config now. > > Without CONFIG_XENO_DRIVERS_CAN_DEBUG this message will never pop up. > > > Slight correction. I AM getting CAN errors at the moment > > 000000088. I believe this is bus error and protocol error. > > If this is the can_id field what do the data fields say? 00 00 80 19 00 00 00 00 But once again, the node is sending. > > -- > Sebastian >
_______________________________________________ Xenomai-help mailing list [email protected] https://mail.gna.org/listinfo/xenomai-help