On 30 May 2012 03:42, Jon Elson <el...@pico-systems.com> wrote:

> When the home command is given, both motors are given
> identical step
> rates toward the home position.  When the first motor trips the home
> switch, the
> step pulses are interrupted to that motor.

I think that one would have to do more than simply interrupt the
steps, as that would cause the motor to slip to an unknown position
(with steppers, not so with step/dir servo amps)

Freezing the commanded position to the stepgen would allow the stepgen
maxaccel to catch the problem, though (possibly)

-- 
atp
If you can't fix it, you don't own it.