So you're not taking advantage of one of the most compelling reasons to use the TSP+BCM combo.
On Fri, Nov 22, 2019 at 8:51 AM Sterling Jacobson <[email protected]> wrote: > I don’t use the remote link, or the TSP PS units. > > > > *From:* AF <[email protected]> *On Behalf Of * Ken Hohhof > *Sent:* Thursday, November 21, 2019 6:17 PM > *To:* 'AnimalFarm Microwave Users Group' <[email protected]> > *Subject:* Re: [AFMUG] 48 Volt Battery Revert > > > > I wouldn’t think the Mean Well power supply would be compatible with the > remote link on the BCM. > > https://www.tracopower.com/products/tsp-bcm.pdf > > > > I think the TSP-BCMU360 can be fed from any brand of power supply, but > it’s a different animal probably best for smallish batteries. > > > > *From:* AF <[email protected]> *On Behalf Of *Sterling Jacobson > *Sent:* Thursday, November 21, 2019 5:56 PM > *To:* AnimalFarm Microwave Users Group <[email protected]> > *Subject:* Re: [AFMUG] 48 Volt Battery Revert > > > > I use the TSP-BCM48(A). > > > > https://www.trcelectronics.com/View/TRACO-Power/TSP-BCM48.shtml > > > > Around $170 > > > > Takes a 48v input, so I use the Mean Well 48v 10A PSU for about $100 to > feed it. > > > > And a string of four 12v 52AH batteries. > > > > > > *From:* AF <[email protected]> *On Behalf Of *Jesse DuPont > *Sent:* Thursday, November 21, 2019 4:02 PM > *To:* AnimalFarm Microwave Users Group <[email protected]>; Matt < > [email protected]> > *Subject:* Re: [AFMUG] 48 Volt Battery Revert > > > > This one is for 48V. It's not Meanwell and it's expensive, but it's > functionally the same as the DR-UPS40, but for 48V. I imagine Meanwell OEMs > this for RLH. > > > https://www.fiberopticlink.com/product/48vdc-ups-battery-charge-controller-module/ > > *Jesse DuPont* > > Network Architect > email: [email protected] > Celerity Networks LLC > > Celerity Broadband LLC > Like us! facebook.com/celeritynetworksllc > > Like us! facebook.com/celeritybroadband > > On 11/21/19 10:37 AM, Matt wrote: > > We use Meanwell DIN mount stuff for battery revert. For 24 volt systems we > use. > > > > DRP-240-24 - power supply > > DR-UPS40 - battery revert > > > > I want to move to 48 volt battery banks now instead of up converting 24 to 48. > > > > So what is a version of DR-UPS40 that is DIN mount and supports 48 volt? > > > > > -- > AF mailing list > [email protected] > http://af.afmug.com/mailman/listinfo/af_af.afmug.com >
-- AF mailing list [email protected] http://af.afmug.com/mailman/listinfo/af_af.afmug.com