What am I missing not using the TSP power supply and remote link? From: AF <[email protected]> On Behalf Of Matt Sent: Friday, November 22, 2019 9:30 AM To: AnimalFarm Microwave Users Group <[email protected]> Subject: Re: [AFMUG] 48 Volt Battery Revert
So what is the remote link for? On Fri, Nov 22, 2019 at 7:56 AM Josh Baird <[email protected]<mailto:[email protected]>> wrote: So you're not taking advantage of one of the most compelling reasons to use the TSP+BCM combo. On Fri, Nov 22, 2019 at 8:51 AM Sterling Jacobson <[email protected]<mailto:[email protected]>> wrote: I don’t use the remote link, or the TSP PS units. From: AF <[email protected]<mailto:[email protected]>> On Behalf Of Ken Hohhof Sent: Thursday, November 21, 2019 6:17 PM To: 'AnimalFarm Microwave Users Group' <[email protected]<mailto:[email protected]>> Subject: Re: [AFMUG] 48 Volt Battery Revert I wouldn’t think the Mean Well power supply would be compatible with the remote link on the BCM. https://www.tracopower.com/products/tsp-bcm.pdf I think the TSP-BCMU360 can be fed from any brand of power supply, but it’s a different animal probably best for smallish batteries. From: AF <[email protected]<mailto:[email protected]>> On Behalf Of Sterling Jacobson Sent: Thursday, November 21, 2019 5:56 PM To: AnimalFarm Microwave Users Group <[email protected]<mailto:[email protected]>> Subject: Re: [AFMUG] 48 Volt Battery Revert I use the TSP-BCM48(A). https://www.trcelectronics.com/View/TRACO-Power/TSP-BCM48.shtml Around $170 Takes a 48v input, so I use the Mean Well 48v 10A PSU for about $100 to feed it. And a string of four 12v 52AH batteries. From: AF <[email protected]<mailto:[email protected]>> On Behalf Of Jesse DuPont Sent: Thursday, November 21, 2019 4:02 PM To: AnimalFarm Microwave Users Group <[email protected]<mailto:[email protected]>>; Matt <[email protected]<mailto:[email protected]>> Subject: Re: [AFMUG] 48 Volt Battery Revert This one is for 48V. It's not Meanwell and it's expensive, but it's functionally the same as the DR-UPS40, but for 48V. I imagine Meanwell OEMs this for RLH. https://www.fiberopticlink.com/product/48vdc-ups-battery-charge-controller-module/ Jesse DuPont Network Architect email: [email protected]<mailto:[email protected]> Celerity Networks LLC Celerity Broadband LLC Like us! facebook.com/celeritynetworksllc<http://facebook.com/celeritynetworksllc> [cid:[email protected]] Like us! facebook.com/celeritybroadband<http://facebook.com/celeritybroadband> On 11/21/19 10:37 AM, Matt wrote: We use Meanwell DIN mount stuff for battery revert. For 24 volt systems we use. DRP-240-24 - power supply DR-UPS40 - battery revert I want to move to 48 volt battery banks now instead of up converting 24 to 48. So what is a version of DR-UPS40 that is DIN mount and supports 48 volt? -- AF mailing list [email protected]<mailto:[email protected]> http://af.afmug.com/mailman/listinfo/af_af.afmug.com -- AF mailing list [email protected]<mailto:[email protected]> http://af.afmug.com/mailman/listinfo/af_af.afmug.com
-- AF mailing list [email protected] http://af.afmug.com/mailman/listinfo/af_af.afmug.com