Probes not working -- this sounds like an internal configuration issue, have you looked at the logs? What are the errors? What is happening? What version of PowerCode are you on? Most development is on version 19/20, so if you're still on 18, you won't get bug fixes.

What issues are you having with the MikroTiks? Yes, PC does not support higher level MikroTik configs, but there's not much to configure... it's pretty much plug and play.

The authentication is only plain text if you haven't turned on encryption in the API (agreed it should default to that, but it doesn't).

Simon is half the reason PowerCode is in the state it is today... don't blame him.

On 12/12/19 4:34 PM, Steve Jones wrote:
Powercode has become quite a joke. Half our probes havent worked for months and they dont even respond to the ticket. We had to spin up Librenms just to get monitoring data

Trying to integrate mikrotik BMUs and having issues, they have zero legitimate documentation and when you ask whats supposed to be happening they tell you to seek out a consultant and that the info may be proprietary.

Thats all bad enough, but i figure ill do some packet sniffing to find out what the communication is between the billing server and the mikrotik, maybe find out I misconfigured something, come to find out the nitwits are sending out the authentication in PLAIN TEXT. They dont even have a disclaimer when you add one of these. but christ, if youre operating an off network BMU, your infrastructure credentials are getting tossed into the ether like its nothing.

I wish simon hadnt left


--
AF mailing list
[email protected]
http://af.afmug.com/mailman/listinfo/af_af.afmug.com

Reply via email to