*rb2011 with ports 2/3/4/5 set to hardware switch (ether2 master, 3/4/5 slave). Ports 6/7/8/9 are hardware switch (ether6 master, 7/8/9 slave). *From the rb2011 it goes to the Ethernet half of the SyncInjector. *From the POE half of the SyncInjector it goes to WB gigeapc HV surge suppressors and then to the ePMP radios.
Two of the ePMP radios are powered up and running gige. Neither are receiving CMM sync (top of the ePMP says "Not receiving GPS sync"). The remaining 6 APs aren't even powering up/linking up. Any ideas before I start swapping parts? Is it OK to have the surge between SyncInjectors and ePMP? On top of all of this the SiteMonitor isn't talking to the POE injector or the two Gig SyncInjectors. I have them all daisy chained and verified they're snapped in place. The POE injector is powering Ubnt radios just fine. Josh Luthman Office: 937-552-2340 Direct: 937-552-2343 1100 Wayne St Suite 1337 Troy, OH 45373