I have ePMP radios running on Netonix switches with no problem and in most cases I do switch the blues and the Browns but I have had occasions where I forgot to switch it and they run fine on a standard microtech were ubiquity pin out but they or 24 V
Sent from my iPhone > On Oct 7, 2015, at 12:48, Josh Luthman <[email protected]> wrote: > > I thought Netonix could simply swap the polarity? > > The pinout is the same, but blue/brown is hot/neutral for Ubnt/Mikrotik > > brown/blue is hot/neutral for Motorola/Trango/Cambium > > > Josh Luthman > Office: 937-552-2340 > Direct: 937-552-2343 > 1100 Wayne St > Suite 1337 > Troy, OH 45373 > >> On Wed, Oct 7, 2015 at 1:47 PM, Darin Steffl <[email protected]> wrote: >> Hello all, >> >> We're going to power some ePMP GPS AP's with a Netonix switch. I understand >> I can power them with either 24V or 48V but the pinout is different than >> standard Ubiquiti passive POE that we're used to. >> >> Which color wires do we swap on one side of the cable termination to >> properly power the ePMP GPS AP's? I found online possibly we swap the blue >> and brown pairs but just want to double check here. >> >> Thanks >> >> -- >> Darin Steffl >> Minnesota WiFi >> www.mnwifi.com >> 507-634-WiFi >> Like us on Facebook >