At 10:56 AM 12/13/2008, you wrote: >I have contacted WLL tech support for a replacement, but will be down >until it arrives. Any substitutions recommended, as well as a better >way to route this line so it doesn't happen again?
I put a piece of something between the line and the copper pipe and then gently ty-wrapped it so it wouldn't move. I've heard people say you can get suitable tubing at McMaster-Carr. Remember it carries boiling water at a fair amount of pressure. The hot ticket might be -3 or -4 teflon brake line. The stainless braid should keep it from wearing out but finding ways to connect it to the boilers might be tricky and it's bend radius is rather large. Ira --~--~---------~--~----~------------~-------~--~----~ You received this message because you are subscribed to the Google Groups "Brewtus" group. To post to this group, send email to [email protected] To unsubscribe from this group, send email to [email protected] For more options, visit this group at http://groups.google.com/group/brewtus?hl=en -~----------~----~----~----~------~----~------~--~---