John, the only thing that I did different was to drain the brew boiler
( through the group)while I was draining the steam boiler.

I have a Vibe Pump and I always made sure that I would run it for
about 45 seconds  and a 45 second rest.

I am stil able to pull shots, however, as soon as the element on the
brew boiler kicks in, it leaks through the element nut. Obviously,
while I am pulling a shot it gets worst.

I am just trying to understand what went wrong in the descaling
process..... and I wonder if the heating element has a gasket....

My machine is 14 months old and WLL warranty expired and they have
been very nice. The good news is that I have an extended warranty
through American Express and I could have it fixed here in Houston .
Therefore, I want to make sure if in order to remove the element, the
boiler has to be removed from the machine because if that is the case
I would rather to get a new boiler.....

The heating element is very hard to tighten or remove the because I
have to hold the boiler at the same time. I even unsucessfully tried
with an of oil wrench  holding it.....

My machine also has those big holes under both boilers, however, ths
situation would be the same. How to securely hold the boiler while you
try either to remove or tighten the heating element?



On Feb 27, 4:57 pm, mariowar <[email protected]> wrote:
> I descaled my Brewtus III  with Dezcal following John Brinkman's
> instructions :
>
> Steam Boiler
> At operating temp
>
> 1. Switch machine off
> 2. Open water tap to remove as much water as possible from steam
> boiler, close tap again
> 3. Disconnect water level sensor (pull the wire off)
> 4. Open steam wand
> 5. Turn machine on, takes quite a while for the pump to fill up the
> steam boiler, water will start coming out of the steam tip when it is
> full
> 6. Switch off machine
> 7. Reconnect water level sensor
> 8. Switch machine on
> 9. Leave at operating temp for 1hr
> 10. repeat
>
> However, on step # 2 I  Also got water out  the group ( intervals of 1
> minute), until no more water got out draining the brew boiler
> too..............
> On step 5, after turning the machine on , after around 30 seconds
> there was a burn rubber smell for about 10 seconds, the the auto fill
> kicked and I continued  the descaling process.
> At the end I run some of the water ith descaler through the brew head
> and I noticed that it had way less scale than the steam bolier which
> had around 2  8 ounce glasses of yellow water until the water became
> cristal clear.
>
> At the end I got a leak underneath the brew boiler's element ( around
> the nut)....
> Could be the element's gasket?   I wonder if it is possible to take
> the element out without taking the boiler out of the machine........
>
> Have you experienced something like it?

-- 
You received this message because you are subscribed to the Google Groups 
"Brewtus" group.
To post to this group, send email to [email protected].
To unsubscribe from this group, send email to 
[email protected].
For more options, visit this group at 
http://groups.google.com/group/brewtus?hl=en.