Herman, I have the same problem with my early model Brewtus I. After 
installing WLL's PID kit, the steam boiler pops the over-pressure valve and 
the temperature breaker with the red button (my button broke off when I 
pressed it to re-set). I completely disassembled the machine at that point 
and found suprisingly little water in the steam boiler. The Parker 
electro-valve (solenoid) seemed to stick and calcium deposits were removed 
form the piston. Maybe the boiler wasn't getting enough water?
I asked WLL for a quote on the hi-temp-breaker, the pressure-stat, and the 
level regulator/control board. They don't have the level regulator/control 
board in stock and Tracy said: "This means it is either not ordered, or we 
no longer carry it." I can't find it anywhere else (any suggestions, 
anyone). 

On Friday, August 28, 2015 at 8:43:17 AM UTC-7, herman dickens wrote:
>
> Hi all. There's a reset switch on top of the steam boiler with a little 
> red button. My switch is broken. Does anyone have the part number? Does 
> someone keep the parts in stock? Thanks